Indoor Unit
Outdoor Unit
Model
CS-PA12KKD
CU-PA12KKD
CS-PA16KKD
CU-PA16KKD
COOL
HEAT
COOL
HEAT
Single, 220 - 240V, 50Hz
Single, 220 - 240V, 50Hz
Power/Current
[W]
1290 - 1330 1100 - 1130 1790 - 1840 1840 - 1890
[A]
6.00-5.70
5.20-5.00
8.40-8.00
8.50-8.10
Refrigerant
[k
g
]
R22*
0.920
R22*
0.890
Cooling Capacity
[kW]
3.600-3.650
4.600-4.600
Heatling Capacity
[kW]
4.000-4.050
5.300-5.350
Noise Level
JIS C 9612 [<70 dB(A)]
[dB(A)]
39 - 39
39 - 39
42 - 42
40 - 40
Conditions 1m Distance
Max. cooling
49 - 49
50 - 50
50 - 50
52 - 52
Air Circulation
[m
3
/min.]
11.8
12.0
12.2
12.4
Product Weight
[k
g
]
9.0
9.0
34
40
Dimensions (H × W × D)
[mm]
848 × 204 × 290
848 × 204 × 290
780 × 289 × 540
780 × 289 × 540
PRODUCT SPECIFICATION
42
*60
g
for air purging is not included.
Test conditions
1.
Temperature (
°C
)
Indoor
Outdoor
*DBT
*WBT
*DBT
*WBT
COOLING
27
19
35
24
HEATING
20
12
7
6
2. Standard piping length: 5 m (Includes Indoor Unit piping length).
3. Air
fi
lters are attached.