8
MODEL
INDOOR
CS-NE12JKE-1, CS-XE12JKE-6
OUTDOOR
CU-NE12JKE-1
Performance Test Condition
EUROVENT
Power Supply
Phase, Hz
Single, 50
V
230
Min.
Mid.
Max.
Cooling
Capacity
kW
0.60
3.50
4.00
BTU/h
—
—
—
Kcal/h
520
3010
3440
Running Current
A
—
4.3
—
Input Power
W
120
910
1.17k
Annual Consumption
kWh
—
455
—
EER
W/W
5.00
3.85
3.42
Kcal/hW
4.33
3.31
2.94
Power Factor
%
—
92
—
Indoor Noise (H / L / QLo)
dB-A
42 / 29 / 26
Power Level dB
58 / 45 / 42
Outdoor Noise (H / L)
dB-A
48 / -
Power Level dB
63 / -
Heating
Capacity
kW
0.60
4.80
6.60
BTU/h
—
—
—
Kcal/h
520
4130
5680
Running Current
A
—
5.8
—
Input Power
W
115
1.25k
1.85k
COP
W/W
5.22
3.84
3.57
Kcal/hW
4.52
3.30
3.07
Power Factor
%
—
94
—
Indoor Noise (H / L / QLo)
dB-A
42 / 33 / 30
Power Level dB
58 / 49 / 46
Outdoor Noise (H / L)
dB-A
50 / -
Power Level dB
65 / -
Low Temp. : Capacity (kW) / I.Power (W) / COP
4.78 / 1.64k / 2.91
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP
3.86 / 1.74k / 2.22
Max Current (A) / Max Input Power (W)
8.4 / 1.85k
Starting Current (A)
5.8
Compressor
Type
Hermetic Motor
Motor Type
Brushless (4-poles)
Output Power
W
750
In
door F
a
n
Type
Cross-flow Fan
Material
ASG20K1
Motor Type
Transistor (8-poles)
Input Power
W
47
Output Power
W
40
Speed
QLo
Cool/Fan
rpm
760
Heat
rpm
950
Lo
Cool/Fan
rpm
850
Heat
rpm
1010
Me
Cool/Fan
rpm
1050
Heat
rpm
1150
Hi
Cool/Fan
rpm
1260
Heat
rpm
1300
SHi
Cool/Fan
rpm
1320
Heat
rpm
1340
Summary of Contents for CS-NE9JKE-1
Page 12: ...12 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control...
Page 13: ...13 5 Dimensions 5 1 Indoor Unit...
Page 14: ...14 5 2 Outdoor Unit...
Page 15: ...15 6 Refrigeration Cycle Diagram...
Page 16: ...16 7 Block Diagram...
Page 17: ...17 8 Wiring Connection Diagram 8 1 Indoor Unit...
Page 18: ...18 8 2 Outdoor Unit...
Page 19: ...19 9 Electronic Circuit Diagram 9 1 Indoor Unit...
Page 20: ...20 9 2 Outdoor Unit...
Page 21: ...21 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board...
Page 22: ...22 10 1 2 Power Printed Circuit Board 10 1 3 Indicator Printed Circuit Board...
Page 24: ...24 10 2 Outdoor Unit...
Page 79: ...79 16 1 3 To remove discharge grille...
Page 80: ...80 16 1 4 To remove control board 16 1 5 To remove cross flow fan and indoor fan motor...
Page 81: ...81...
Page 83: ...83 17 Technical Data 17 1 Operation Characteristics 17 1 1 CU NE9JKE 1...
Page 84: ...84...
Page 85: ...85...
Page 86: ...86...
Page 87: ...87 17 1 2 CU NE12JKE 1...
Page 88: ...88...
Page 89: ...89...
Page 90: ...90...