31
Note:
Secure the connection cable onto the control board with the holder.
Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires for safety reason.
12.2.4.1 Wire Stripping Connecting and Requirement
Recommended
length (mm)
WARNING
This equipment must be properly earthed.
Recommended
length (mm)
a
35
b
35
c
35
d
35
Tape
Connection cable
Indoor & outdoor
Connection cable
Escapement
Terminal
Board
Earth Wire
longer than
others
AC wires
for safety
reason
Outdoor unit
Indoor & outdoor
Connection cable
Holder
WARNING
RISK OF FIRE
JOINING OF WIRES
MAY CAUSE
OVERHEATING
AND FIRE.
OR
OR
OR
Wire stripping
No loose strand
when inserted
10
±
1
m
m
5 mm
or more
Indoor/outdoor
connection
terminal board
(gap between wires)
Conductor
fully inserted
Conductor
over inserted
Conductor not
fully inserted
ACCEPT
PROHIBITED
PROHIBITED
Use complete wire without joining.
Use approved socket and plug with earth pin.
Wire connection in this area must follow to national wiring rules.
Do not joint wires