 Safety precautions

2-3. Checking for presence of refrigerant

• The area shall be checked with an 

appropriate refrigerant detector prior to and 
during work, to ensure the technician is aware 
of potentially fl ammable atmospheres.

• Ensure that the leak detection equipment 

being used is suitable for use with fl ammable 
refrigerants, i.e. non sparking, adequately 
sealed or intrinsically safe.

• In case of leakage/spillage happened, 

immediately ventilate area and stay upwind 
and away from spill/release.

• In case of leakage/spillage happened, do 

notify persons down wind of the leaking/
spill, isolate immediate hazard area and keep 
unauthorized personnel out.

2-4. Presence of fi re extinguisher

• If any hot work is to be conducted on the 

refrigerating equipment or any associated 
parts, appropriate fi re extinguishing 
equipment shall be available at hand.

• Have a dry powder or CO

2

 fi re extinguisher 

adjacent to the charging area.

2-5. No ignition sources

• No person carrying out work in relation to a 

refrigerating system which involves exposing 
any pipe work that contains or has contained 
fl ammable refrigerant shall use any sources 
of ignition in such a manner that it may lead to 
the risk of fi re or explosion. He/She must not 
be smoking when carrying out such work.

• All possible ignition sources, including 

cigarette smoking, should be kept suffi ciently 
far away from the site of installation, 
repairing, removing and disposal, during 
which fl ammable refrigerant can possibly be 
released to the surrounding space.

• Prior to work taking place, the area around 

the equipment is to be surveyed to make 
sure that there are no fl ammable hazards or 
ignition risks.

• “No Smoking” signs shall be displayed.

2-6. Ventilated area

• Ensure that the area is in the open or that it is 

adequately ventilated before breaking into the 
system or conducting any hot work.

• A degree of ventilation shall continue during 

the period that the work is carried out.

• The ventilation should safely disperse any 

released refrigerant and preferably expel it 
externally into the atmosphere.

2-7. Checks to the refrigerating equipment

• Where electrical components are being 

changed, they shall be fi t for the purpose and 
to the correct specifi cation.

• At all times the manufacturer’s maintenance 

and service guidelines shall be followed.

• If in doubt consult the manufacturer’s 

technical department for assistance.

• The following checks shall be applied to 

installations using fl ammable refrigerants.

 

- The actual refrigerant charge is in 

accordance with the room size within 
which the refrigerant containing parts are 
installed. 

 

- The ventilation machinery and outlets 

are operating adequately and are not 
obstructed. 

 

- If an indirect refrigerating circuit is being 

used, the secondary circuit shall be 
checked for the presence of refrigerant.

 

- Marking to the equipment continues to be 

visible and legible. Markings and signs that 
are illegible shall be corrected.

 

- Refrigerating pipe or components are 

installed in a position where they are 
unlikely to be exposed to any substance 
which may corrode refrigerant containing 
components, unless the components 
are constructed of materials which are 
inherently resistant to being corroded or 
are properly protected against being so 
corroded.

2-8. Checks to electrical devices

• Repair and maintenance to electrical 

components shall include initial safety checks 
and component inspection procedures.

• Initial safety checks shall include but not limit 

to:-

 

- That capacitors are discharged: this 

shall be done in a safe manner to avoid 
possibility of sparking. 

 

- That there no live electrical components 

and wiring are exposed while charging, 
recovering or purging the system. 

 

- That there is continuity of earth bonding.

• At all times the manufacturer’s maintenance 

and service guidelines shall be followed.

• If in doubt consult the manufacturer’s 

technical department for assistance.

• If a fault exists that could compromise safety, 

then no electrical supply shall be connected to 
the circuit until it is satisfactorily dealt with.

• If the fault cannot be corrected immediately 

but it is necessary to continue operation, an 
adequate temporary solution shall be used.

• The owner of the equipment must be 

informed or reported so all parties are advised 
thereinafter.

ACXF55-28780_SS0720-0.indd   8

25/6/2020   11:10:07 AM

Summary of Contents for CS-MRZ16WKR

Page 1: ...ackaged in the indoor unit and removed by the installer before installation Kindly consult authorised dealer for connectivity validity Operating Instructions Air Conditioner Model No Indoor Unit Outdoor Unit Single Split CS RZ25WKRW CS RZ35WKRW CS RZ42WKRW CS RZ50WKRW CS MRZ16WKR CS MRZ20WKR CU RZ25WKR CU RZ35WKR CU RZ42WKR CU RZ50WKR Outdoor Unit Multi Split CU 2Z52VBR CU 3Z54VBR CU 4Z71VBR CU 4Z...

Page 2: ... time Press and hold for approximately 5 seconds to show time in 12 hour am pm or 24 hour indication 2 Confirm SET Flexibility to connect Single Split System or Multi Split System Air Conditioner to suit your needs For complete product features please refer to catalogue AIR CONDITIONER ON OFF SET TIMER CANCEL OFF ON AIR SWING TEMP OFF ON MODE FAN SPEED QUIET POWERFUL ECO SLEEP AIR CONDITIONER ON O...

Page 3: ...unit They are subject to change without notice for future improvement B Basic operation 2 Press MODE to select the desired mode AUTO HEAT COOL FAN DRY 1 Press OFF ON OFF ON to start stop the operation POWER Please note that the indication is on display to start the unit 3 Select the desired temperature TEMP Up Down Selection range 16 0 C 30 0 C 60 F 86 F Press and hold for approximately 10 seconds...

Page 4: ... usage of any specified refrigerant type Using refrigerant type other than the specified may cause product damage burst and injury etc Do not use means to accelerate the defrosting process or to clean other than those recommended by manufacturer Any unfit method or using incompatible material may cause product damage burst and serious injury Do not install the unit in a potentially explosive or fl...

Page 5: ...od animals plants artwork or other objects This may cause quality deterioration etc Do not use any combustible equipment in front of the airflow outlet to avoid fire propagation Do not expose plants or pet directly to airflow to avoid injury etc Do not touch the sharp aluminium fin sharp parts may cause injury Do not switch ON the indoor unit when waxing the floor After waxing aerate the room prop...

Page 6: ...g taping etc Handling of R32 is similar to R410A Operation maintenance repairing and refrigerant recovery should be carried out by trained and certified personnel in the use of flammable refrigerants and as recommended by the manufacturer Any personnel conducting an operation servicing or maintenance on a system or associated parts of the equipment should be trained and certified Any part of refri...

Page 7: ... 12 and comply with national regulations Always contact to local municipal offices for proper handling 2 Servicing 2 1 Service personnel The system is inspected regularly supervised and maintained by a trained and certified service personnel who is employed by the person user or party responsible Ensure the actual refrigerant charge is in accordance with the room size within which the refrigerant ...

Page 8: ...ere 2 7 Checks to the refrigerating equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the manufacturer s maintenance and service guidelines shall be followed If in doubt consult the manufacturer s technical department for assistance The following checks shall be applied to installations using flammable refrigeran...

Page 9: ...nected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation Particular attention shall be paid to the following to ensure that by working on ele...

Page 10: ... with the equipment and its operation b Isolate system electrically c Before attempting the procedure ensure that mechanical handling equipment is available if required for handling refrigerant cylinders all personal protective equipment is available and being used correctly the recovery process is supervised at all times by a competent person recovery equipment and cylinders conform to the approp...

Page 11: ...ber of cylinders for holding the total system charge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant i e special cylinders for the recovery of refrigerant Cylinders shall be complete with pressure relief valve and associated shut off valves in good working order Recovery cylinders are evacuated and if possible cooled before reco...

Page 12: ...saving without sacrificing comfort To switch between POWERFUL ECO POWERFUL ECO Upper direction Do not adjust the flap by hand Lateral direction For lateral direction it is manually adjustable as shown To adjust airflow direction AIR SWING Upper direction Lateral direction exit setting Indicator POWER TIMER ECO AIR CONDITIONER ON OFF SET TIMER CANCEL OFF ON AIR SWING TEMP OFF ON MODE FAN SPEED QUIE...

Page 13: ...ill activate in sequence Timer operation is based on the clock set in the remote control and repeats daily once set For clock setting please refer to Quick Guide 2 sets of ON and OFF timers are available to turn ON or OFF the unit at different preset time This operation provides you with a comfortable environment while sleeping It will automatically adjust the sleep pattern temperature during the ...

Page 14: ...tem which HEAT mode has been locked if operation mode other than HEAT is selected the indoor unit stops and the POWER indicator blinks COOL Provides efficient comfort cooling to suit your needs DRY Unit operates at low fan speed to give a gentle cooling operation FAN To circulate air in the room Energy saving temperature setting Operating the unit within the recommended temperature range may save ...

Page 15: ...WBT DBT WBT DBT WBT COOL Max 32 89 6 23 73 4 46 114 8 26 78 8 46 114 8 26 78 8 Min 16 60 8 11 51 8 10 14 0 10 14 0 HEAT Max 30 86 0 24 75 2 18 64 4 24 75 2 18 64 4 Min 16 60 8 15 5 0 15 5 0 16 3 2 DBT Dry bulb temperature WBT Wet bulb temperature 1 CU RZ25WKR CU RZ35WKR CU RZ42WKR CU RZ50WKR 2 CU 2Z52VBR CU 3Z54VBR CU 4Z71VBR CU 4Z80VBR CU 5Z100VBR ACXF55 28780_SS0720 0 indd 15 25 6 2020 11 10 09 ...

Page 16: ...ir filter Attach air filter Insert into the unit Anti bacterial filter Anti bacterial filter Clean the filter whenever necessary Wash rinse the filter gently with water to avoid damage to the filter Dry the filter thoroughly under the shade away from fire or direct sunlight Replace the filter every 10 years or replace any damaged filter Part no CZ SA22P Aluminium fin Front panel Air filters Indoor...

Page 17: ...due to damp smell emitted by the wall carpet furniture or clothing Cracking sound during operation Changes of temperature caused the expansion contraction of the unit Water flowing sound during operation Refrigerant flow inside the unit Mist emerges from indoor unit Condensation effect due to cooling process Outdoor unit emits water steam Condensation or evaporation occurs on pipes Discoloration o...

Page 18: ...o select COOL HEAT operation After 15 minutes of operation it is normal to have the following temperature difference between the air inlet and outlet vents COOL 8 C 14 4 F HEAT 14 C 25 2 F The units are not going to be used for a long period of time Activate HEAT mode for 2 3 hours to remove moisture left in the internal parts thoroughly to prevent mould growth Turn off the power supply and unplug...

Page 19: ...e sensor abnormality H 35 Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe temperature sensor abnormality H 37 Outdoor liquid pipe temperature sensor abnormality H 38 Indoor outdoor mismatch brand code H 39 Abnormal indoor operating unit or standby units Diagnostic display Abnormality Protection control H 41 Abnormal wiring or piping connection H 50 Ventilation fan motor lock...

Page 20: ...hows that this equipment uses a flammable refrigerant If the refrigerant is leaked together with an external ignition source there is a possibility of ignition This symbol shows that the Operation Instructions should be read carefully This symbol shows type of flammable refrigerant contained in the system This symbol shows that a service personnel should be handling this equipment with reference t...