Panasonic CS-MRE12QKR Operating Instructions Manual Download Page 8

8

Multi air conditioner system

Multi air conditioner systems save space by 
letting you connect multiple indoor units to a 
single outdoor unit.
• For complete product features, please refer 

catalogue.

Indoor units

Outdoor unit

Operation conditions

Use this air conditioner under the following temperature range.
DBT  : Dry bulb temperature
WBT : Wet bulb temperature

Temperature (°C)

Indoor

Outdoor

DBT

WBT

DBT

WBT

COOL

Max.

32

23

46

26

Min.

16

11

-10

-

HEAT

Max.

30

-

24

18

Min.

16

-

-15

-16

Indoor units

• It is possible to operate the indoor units 

individually or simultaneously. The priority 
of operation is placed on the 

fi

 rst unit that 

turned on.

• During operation, HEAT and COOL modes 

cannot activate at the same time for different 
indoor units.

• The power indicator blinks to indicate the 

indoor unit is standing by for a different 
operation mode.

Summary of Contents for CS-MRE12QKR

Page 1: ... CU 4E23QBR CU 4E27QBR CU 5E34QBR Operating Instructions Air Conditioner F569673 Operating Instructions Air Conditioner Thank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit read these operating instructions thoroughly and keep them for future reference ...

Page 2: ...C Not applicable for FAN mode Operating the unit within the recommended temperature may save energy HEAT 20 C 24 C COOL 26 C 28 C DRY 1 C 2 C lower than room temperature The set temperature selection range can be customized according to requirement Please consult authorised dealer To dim or restore the unit s indicator brightness press and hold for 5 seconds Use remote control within 8 m from the ...

Page 3: ... AC RC 2 3 1 MODE ON OFF SET CANCEL TIMER POWERFUL FAN SPEED ECONOMY 1 2 3 SET CHECK CLOCK RESET AC RC MODE AIR CONDITIONER OFF ON AIR SWING ON OFF SET CANCEL TIMER POWERFUL FAN SPEED ECONOMY 1 2 3 SET CHECK CLOCK RESET AC RC MODE AIR CONDITIONER AIR SWING 1 2 3 MRE5QKR MRE7QKR MRE9QKR MRE12QKR MRE18QKR MRE24QKR MODE ON OFF SET CANCEL TIMER POWERFUL AIR SWING FAN SPEED ECONOMY 1 2 3 SET CHECK CLOC...

Page 4: ...the internal parts repair install remove and reinstall the unit Improper installation and handling will cause leakage electric shock or fire Confirm with authorised dealer or specialist on usage of any specified refrigerant type Using refrigerant type other than the specified may cause product damage burst and injury etc Do not install the unit in a potentially explosive or flammable atmosphere Fa...

Page 5: ... outdoor unit Do not wash the indoor unit with water benzine thinner or scouring powder to avoid damage or corrosion at the unit Do not use for preservation of precise equipment food animals plants artwork or other objects This may cause quality deterioration etc Do not use any combustible equipment in front of the airflow outlet to avoid fire propagation Do not expose plants or pet directly to ai...

Page 6: ...ure outdoor temperature and room temperature HEAT To enjoy warm air Unit takes a while to warm up The POWER indicator blinks during this operation COOL To enjoy cool air Use curtains to screen off sunlight and outdoor heat to reduce power consumption during COOL mode DRY To dehumidify the environment Unit operates at low fan speed to give a gentle cooling operation FAN To circulate air in the room...

Page 7: ...ted in all modes and can be cancelled by pressing the respective button again Cannot be selected at the same time To set the timer 2 sets of ON and OFF timers are available to turn ON or OFF the unit at different preset times ON OFF SET CANCEL TIMER 1 2 3 CANCEL TIMER 3 1 2 3 1 Select ON or OFF timer Example OFF at 22 00 Each time pressed OFF Cancel 2 Set the time 2 3 Confirm SET TIMER To cancel O...

Page 8: ... Dry bulb temperature WBT Wet bulb temperature Temperature C Indoor Outdoor DBT WBT DBT WBT COOL Max 32 23 46 26 Min 16 11 10 HEAT Max 30 24 18 Min 16 15 16 Indoor units It is possible to operate the indoor units individually or simultaneously The priority of operation is placed on the first unit that turned on During operation HEAT and COOL modes cannot activate at the same time for different ind...

Page 9: ... the filter surface Dry the filters thoroughly under shade away from fire or direct sunlight Replace any damaged filters Remove air filter Attach air filter Insert into the unit Anti bacterial filter Anti bacterial filter Clean the filter whenever necessary Wash rinse the filter gently with water to avoid damage to the filter Dry the filter thoroughly under the shade away from fire or direct sunli...

Page 10: ...re compressor oil circulation Check the following before calling for servicing Symptom Check Operation in HEAT COOL mode is not working efficiently Set the temperature correctly Close all doors and windows Clean or replace the filters Clear any obstruction at the air inlet and air outlet vents Noisy during operation Check if the unit has been installed at an incline Close the front panel properly ...

Page 11: ...n Union These symbols are only valid in the European Union If you wish to discard these items please contact your local authorities or dealer and ask for the correct method of disposal Pb Note for the battery symbol bottom two symbol examples This symbol might be used in combination with a chemical symbol In this case it complies with the requirement set by the Directive for the chemical involved ...

Page 12: ...F569673 SS0214 0 Printed in Malaysia Panasonic Corporation Website http panasonic net Panasonic Corporation 2014 ...

Reviews: