10.6.3. Self Diagnosis display
10.6.3.1. BreakDown Self Diagnosis Function (Three Digits Alphanumeric Code)
·
Once abnormality has been detected during operation, the unit
will immediately stop its operation. (Timer LED blinks.)
·
Although timer LED goes off when power supply is turned off, if
the unit is operated under a breakdown condition, the LED will
light up again.
·
In operation after breakdown repair, error code is not displayed.
The last error code (abnormality) will be saved in IC memory.
·
Timer LED Blinking in Abnormal Operation:
1.
Automatically stops the operation.
2.
Timer LED on display of the indoor unit blinks.
3.
The LED will be off if the unit is turned off or the Error
RESET button on the remote controller is pressed.
·
To display memorized error (Protective operation) status:
1.
Turn the unit on.
2.
Press the CHECK button on the remote controller for
continuously 5 seconds or more with a pointed object to
appear “--” on the display.
3.
Press the “TIMER”
or
button on the remote
controller to appear “H00” on the display. Signal is
transmitted to the main unit.
4.
Press the “TIMER”
button (When the
button is
pressed, the display goes back.) repeatedly and slowly until
Beeps sound (about 5 seconds intermittently) is heard from
main unit.
5.
Then, displayed error code matches to the error code saved
in unit memory. The power LED on the main unit also lights
up.
Note: When the CHECK button is pressed
continuously for 5 seconds again, or when no
operation continues for 30 seconds, or when the
RESET button on remote controller is pressed
with a pointed object, the display is cancelled.
·
To clear memorized error (Protective operation) status after
repair:
1.
Press the AUTO button in main unit continuously for
5seconds or more and release it. (Test run / Pump
downoperation: Beep sound)
2.
Press the CHECK button on remote controller for about 1
second with a pointed object to transmit signal to main unit.
A beep sound is heard from main unit and the data is
cleared.
·
Temporary Operation (Depending on breakdownstatus)
1.
Press the ON/OFF button after selecting Cooling or Heating
operation. (Receiving Beep sound is heard andthe TIMER
LED blinks.)
2.
The unit can temporarily be used until repaired.
26
CS-ME7EB1E / CS-ME10EB1E / CS-ME12EB1E / CS-ME14EB1E
Summary of Contents for CS-ME10EB1E
Page 3: ...1 Safety Precautions 3 CS ME7EB1E CS ME10EB1E CS ME12EB1E CS ME14EB1E ...
Page 4: ...4 CS ME7EB1E CS ME10EB1E CS ME12EB1E CS ME14EB1E ...
Page 6: ...3 Functions 3 1 REMOTE CONTROL 6 CS ME7EB1E CS ME10EB1E CS ME12EB1E CS ME14EB1E ...
Page 7: ...3 2 INDOOR UNIT 7 CS ME7EB1E CS ME10EB1E CS ME12EB1E CS ME14EB1E ...
Page 8: ...8 CS ME7EB1E CS ME10EB1E CS ME12EB1E CS ME14EB1E ...
Page 10: ...5 Dimensions 5 1 Cassette Type 10 CS ME7EB1E CS ME10EB1E CS ME12EB1E CS ME14EB1E ...
Page 11: ...11 CS ME7EB1E CS ME10EB1E CS ME12EB1E CS ME14EB1E ...
Page 12: ...5 2 Grille 12 CS ME7EB1E CS ME10EB1E CS ME12EB1E CS ME14EB1E ...
Page 13: ...6 Refrigeration Cycle Diagram 13 CS ME7EB1E CS ME10EB1E CS ME12EB1E CS ME14EB1E ...
Page 15: ...8 Wiring Diagram 15 CS ME7EB1E CS ME10EB1E CS ME12EB1E CS ME14EB1E ...
Page 17: ...17 CS ME7EB1E CS ME10EB1E CS ME12EB1E CS ME14EB1E ...
Page 21: ...21 CS ME7EB1E CS ME10EB1E CS ME12EB1E CS ME14EB1E ...
Page 31: ...CS ME7EB1E CS ME10EB1E CS ME12EB1E CS ME14EB1E 31 11 Installation Instructions ...
Page 32: ...CS ME7EB1E CS ME10EB1E CS ME12EB1E CS ME14EB1E 32 ...
Page 33: ...CS ME7EB1E CS ME10EB1E CS ME12EB1E CS ME14EB1E 33 ...
Page 34: ...CS ME7EB1E CS ME10EB1E CS ME12EB1E CS ME14EB1E 34 ...
Page 35: ...CS ME7EB1E CS ME10EB1E CS ME12EB1E CS ME14EB1E 35 ...
Page 41: ...41 CS ME7EB1E CS ME10EB1E CS ME12EB1E CS ME14EB1E ...
Page 42: ...42 CS ME7EB1E CS ME10EB1E CS ME12EB1E CS ME14EB1E ...
Page 43: ...43 CS ME7EB1E CS ME10EB1E CS ME12EB1E CS ME14EB1E ...
Page 44: ...44 CS ME7EB1E CS ME10EB1E CS ME12EB1E CS ME14EB1E ...