background image

CS-KU12WKY series
CS-KU18WKYT series
CS-KU18WKY series
CS-KU24WKY series
CS-TU12WKY series
CS-TU18WKY series
CS-TU24WKY series

CU-KU12WKY series
CU-KU18WKYT series
CU-KU18WKY series
CU-KU24WKY series
CU-TU12WKY series
CU-TU18WKY series
CU-TU24WKY series

ACXF55-27510-AE

English

Operating Instructions
Air Conditioner

Thank you for purchasing Panasonic Air Conditioner.
Installation instructions attached.
Before operating the unit, please read these operating 
instructions thoroughly and keep them for future 
reference. 

ACXF55-2751̲OL.ai   1   3/3/2020   9:50:15 AM

ACXF55-2751̲OL.ai   1   3/3/2020   9:50:15 AM

Summary of Contents for CS-KU12WKY Series

Page 1: ...es CU TU12WKY series CU TU18WKY series CU TU24WKY series ACXF55 27510 AE English Operating Instructions Air Conditioner Thank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit please read these operating instructions thoroughly and keep them for future reference ACXF55 2751 OL ai 1 3 3 2020 9 50 15 AM ACXF55 2751 OL ai 1 3 3 2020 9 50 15 AM ...

Page 2: ...rol receiver of the indoor unit FAN DRY Operating the unit at 24 C or higher degrees may save energy Default set temperature is 24 C in COOL mode as per country guidelines ACXF55 2751 OL ai 2 3 3 2020 9 50 35 AM ACXF55 2751 OL ai 2 3 3 2020 9 50 35 AM ...

Page 3: ...11 Cleaning instructions 12 Troubleshooting 13 BEE Regulation 14 Information 15 FAN CHECK MODE POWERFUL AIR SWING FAN SPEED SLEEP TEMP CLEAN DISPLAY TIMER ON OFF LOCK CANCEL SMART 7m ACXF55 2751 OL ai 3 3 3 2020 9 50 35 AM ACXF55 2751 OL ai 3 3 3 2020 9 50 35 AM ...

Page 4: ...liances etc Refer to Table A of Installation instructions table for Amin m Be aware that refrigerant may not contain an odour highly recommended to ensure suitable flammable refrigerant gas detectors are present operating and able to warn of a leak Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handi...

Page 5: ...R410A R22 models Since the working pressure is higher than that of refrigerant R22 models some of the piping and installation and service tools are special Especially when replacing a refrigerant R22 model with a new refrigerant R32 model always replace the conventional piping and flare nuts with the R32 and R410A piping and flare nuts on the outdoor unit side For R32 and R410A the same flare nut ...

Page 6: ...authorizes their competence to handle refrigerants safely in accordance with an industry recognised assessment specification Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants Servicing shall b...

Page 7: ...o any substance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being corroded or are properly protected against being so corroded 2 8 Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures Initial safety checks shall...

Page 8: ... and evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However it is important that best practice is followed since flammability is a consideration The following procedure shall be adhered to remove refrigerant purge the circuit with inert gas evacuate purge again with inert gas open the circuit by cutting or brazin...

Page 9: ...tied of refrigerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 12 Recovery When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrig...

Page 10: ...de and room temp for FAN mode Only indoor unit fan operates as per remote settings Outdoor is OFF so no cooling achieved Provides air circulation in the room SL will be displayed on Remote The unit is turned off after 8 hours This operation provides you with a comfortable environment while sleeping by gradually increase the set temperature 1 C after 3 hours operation This operation is to achieve f...

Page 11: ... start earlier up to 15 minutes before the actual set time in order to achieve the desired temperature on time ON OFF CANCEL 11 CLEAN To clean dust on evap coil of the Air Conditioner Unit To turn ON OFF Wi Fi function of Air Conditioner Unit Select ON or OFF timer Set the time Confirm Wi Fi Example OFF at 14 00 Press the OFF button OFF OFF OFF OFF OFF OFF Wait for 5 second to set timer Press OFF ...

Page 12: ...y under shade away from fire or direct sunlight Replace any damaged filters Ag Clean Filter PM 2 5 filter Clean the filter whenever necessary Don t wash rinse the filter with water The surface of the filter shouldn t be rubbed with any object The filter shouldn t be pulled with strong force as it may get damaged Ag Clean Filter PM 2 5 filter 12 Dust filters PM2 5 Filters Ag Clean Filter ACXF55 275...

Page 13: ...display Unit s Wi Fi connection with the router is activated Wi Fi LED stays ON during unit turn OFF Check unit s Wi Fi connection with router Wi Fi LED countiniuosly blinking 13 ACXF55 2751 OL ai 13 3 3 2020 9 50 39 AM ACXF55 2751 OL ai 13 3 3 2020 9 50 39 AM ...

Page 14: ...Cooling Test Mode for Full Load 100 and Half Load 50 1 Mode Select COOL 2 Temperature a 16 ºC for Full Load 100 3 Air Swing S 4 Fan speed et vane position to 3rd step from top b 17 ºC for Half Load 50 Auto OFF ON Button Indication for Half load Indication for Full load For Full Load For Half Load 14 Open the Front Panel by lifting Intake Grille Follow the below Instructions Maximum DRY FAN DRY FAN...

Page 15: ...ttp www panasonic com in corporate sustainability panasonic india i recycle program html S No 1 All electrical and electronic products are required to be handed over only to the Authorized recycler 2 The product should be handed over only to authorized recycler for disposal 3 4 5 6 Keep the product in isolated area after it becomes non functional un repairable so as to prevent its accidental break...

Page 16: ...here is a possibility of ignition This symbol shows that the Operation Instructions should be read carefully This symbol shows that a service personnel should be handling this equipment with reference to the Installation Instructions This symbol shows that there is information included in the Operation Instructions and or Installation Instructions ACXF55 2751 OL ai 16 3 3 2020 9 50 40 AM ACXF55 27...