1
2
3
6-1-4. Remove the indoor air temperature sensor.
(1) Disconnect the connector CN08 (ROOM 2P) in the control box and remove the indoor air temperature
sensor. (Fig. 10)
6-1-5. Remove the power box and control box.
(1) Remove a screw and remove the terminal cover. (Fig. 11)
(2) Remove the 2 screws and remove the power box cover. (Fig. 11)
(3) Disconnect the power lines (No. 1 and No. 2) / signal line (No. 3) and ground cable from the terminals in
the power box. (Fig. 12)
Indoor air temperature sensor
CN08
Terminal
Fig.10
Fig.11
Fig.12
Ground cable
Terminal cover
Screw
Screw
Power box cover
Power lines / Signal line
23
Summary of Contents for CS-KS18NB4UW & CZ-18BT1U + CU-KS18NKU
Page 39: ......
Page 57: ......
Page 58: ...Operating Instructions CS KS18NB4UW CZ 18BT1U 852 6 4181 211 00 1 APPENDIX B A 2 ...
Page 94: ...Operating Instructions CZ RD515U 852 6 4181 230 00 1 APPENDIX D A 4 ...
Page 105: ......
Page 106: ...A 5 INSTALLATION INSTRUCTIONS CZ RD515U 852 6 4190 592 00 0 APPENDIX E ...
Page 111: ......
Page 112: ...DC1111 0 ...