Operation mode
HEAT :
The POWER indicator blinks at the initial stage. The unit will take some time to
warm up.
• If the HEAT mode system has been locked, and other operation mode is selected,
the indoor unit stops and the POWER indicator blinks.
• Unit may stops warm air supply for deice. The deice indicator ON during this
operation.
COOL :
Provides ef
fi
cient comfort cooling to suit your needs.
DRY
:
Operates at low fan speed for a gentle cooling operation.
FAN
:
To circulate air in the room.
AUTO :
The POWER indicator blinks at the initial stage.
The unit will select an operation mode every 10 minutes depending on the setting
and room temperature.
Energy saving temperature setting
You may save energy when operating the unit within the recommended temperature range.
HEAT :
20.0 °C ~ 24.0 °C / 68 °F ~ 75 °F.
COOL :
26.0 °C ~ 28.0 °C / 79 °F ~ 82 °F.
Air
fl
ow direction
In COOL/DRY mode:
The horizontal
fl
ap swings up/down automatically.
Once the temperature is achieved, the horizontal
fl
ap is
fi
xed at upper position.
In HEAT mode:
The horizontal
fl
ap
fi
xed at the predetermined position.
The vertical
fl
ap swings left/right when the temperature rises.
In COOL/DRY/HEAT mode:
The horizontal
fl
ap swings up/down automatically.
Auto restart control
When power is resumed after a power failure, the operation will restart automatically with the
last operation mode and air
fl
ow direction.
• This control is not applicable when TIMER is set.
Operating conditions
Use this air conditioner in the temperature range indicated in the table.
Temperature °C (°F)
Indoor
Outdoor
DBT
WBT
DBT
WBT
COOL
Max.
32 (89.6)
23 (73.4)
43 (109.4)
26 (78.8)
Min.
16 (60.8)
11 (51.8)
16 (60.8)
11 (51.8)
HEAT
Max.
30 (86.0)
-
24 (75.2)
18 (64.4)
Min.
16 (60.8)
-
-25 (-13.0)
-
+8/15°C
HEAT
Max.
15 (59.0)
-
-
-
Min.
8 (46.4)
-
-25 (-13.0)
-
DBT : Dry bulb temperature, WBT : Wet bulb temperature