68
14.11 ECONAVI Operation
ECONAVI start condition:
When ECONAVI button is pressed.
ECONAVI stop conditions:
When ECONAVI button is pressed again.
When unit is OFF by OFF/ON button.
When unit is OFF when OFF TIMER activates.
When unit is OFF by AUTO OFF/ON button at indoor unit.
When POWERFUL, QUIET, +8/10°C Heat operation activates.
14.11.1 Sunlight Sensor
During ECONAVI operation, the sunlight sensor detects sunlight intensity coming through windows and
differentiates between sunny and cloudy or night to further optimize energy saving by adjusting the temperature.
Sunlight judgment is as following
Sunlight intensity reset
Judge sunlight intensity
Judge ambient condition
Temperature shift
14.11.1.1 Sunlight Intensity Reset
The sunlight intensity will to reset to zero (no sunlight condition) when
o
Each time ECONAVI is activated.
o
Setting temperature is changed.
o
Operation mode is changed.
Summary of Contents for CS-HZ12RKE