![Panasonic CS-E9DKDW Service Manual Download Page 38](http://html1.mh-extra.com/html/panasonic/cs-e9dkdw/cs-e9dkdw_service-manual_4140798038.webp)
•
During heating operation, operate the followings control.
1. During Remote Control setting is 18°C & above
Indoor Fan Speed
Min Hz
More than Hi
27
More than Lo
27
Under Lo
27
However, when less than thermo OFF for 100 sec. continuously, the above control will be cancel.
8.2.1.11. DC Current Protection Control
Purpose
In order to control DC current rise in a compressor low frequency region, load is detected with from indoor/outdoor heat
exchanger temperature, Hz control is performed.
Control contents
1. During cooling and dry except test mode
2. During heating compressor operation, except test mode.
(However, official approval mode removes)
8.2.2. Protection Control For Cooling & Soft Dry Operation
8.2.2.1. Outdoor Air Temperature Control
The compressor operating frequency is regulated in accordance to the outdoor air temperature as shown in the diagram below.
This control will begin one minute after the compressor starts.
38
CS-E9DKDW CU-E9DKD / CS-E12DKDW CU-E12DKD
Summary of Contents for CS-E9DKDW
Page 12: ...4 2 Outdoor Unit 4 2 1 CU E9DKD CU E12DKD 12 CS E9DKDW CU E9DKD CS E12DKDW CU E12DKD ...
Page 13: ...5 Refrigeration Cycle Diagram 13 CS E9DKDW CU E9DKD CS E12DKDW CU E12DKD ...
Page 14: ...6 Block Diagram 14 CS E9DKDW CU E9DKD CS E12DKDW CU E12DKD ...
Page 15: ...7 Wiring Diagram 15 CS E9DKDW CU E9DKD CS E12DKDW CU E12DKD ...
Page 26: ...2 Heating ii Auto Fan Speed 1 Cooling 26 CS E9DKDW CU E9DKD CS E12DKDW CU E12DKD ...
Page 81: ...13 1 2 CS E12DKDW CU E12DKD 81 CS E9DKDW CU E9DKD CS E12DKDW CU E12DKD ...
Page 94: ...94 CS E9DKDW CU E9DKD CS E12DKDW CU E12DKD ...
Page 95: ...How to use electronic circuit diagram 95 CS E9DKDW CU E9DKD CS E12DKDW CU E12DKD ...
Page 96: ...18 3 Remote Control 96 CS E9DKDW CU E9DKD CS E12DKDW CU E12DKD ...