8.1.3. Indoor Fan Motor Operation
There are 31 fan speed numbers assigned for different fan speed operation at designed conditions, as shown in below table. The
fan speed can be set manually using remote control (5 speeds for cooling mode: Lo, Me-, Me, Me+, Hi; 5 speeds for heating: Lo,
Me-, Me, Me+, Shi) or let it automatically changes depending on the operation and its environment.
Fan
Speed
No.
CS-E9BKP
CS-E12BKP
Remark
Voltage
(V)
Cooling
Dry
Heating
Voltage
(v)
Cooling
Dry
Heating
0
OFF
OFF
OFF
OFF
OFF
OFF
- Hot start control.
- Deice control.
1
2
3.03
3.03
3
3.05
SLo
3.05
SLo
- Soft Dry operation mode.
- ON timer pre-operation (D).
- Sleep shift operation (D).
4
3.13
3.13
- Auto operation mode judgment (C/D).
- ON timer preparation sampling (C/D).
5
3.15
3.23
- Auto operation mode judgment (H).
- ON timer preparation sampling (H).
- Sleep shift operation at compressor off.
6
3.16
Lo
3.29
Lo
- Sleep shift operation (C).
- ON timer pre-operation at Auto fan (C).
7
3.23
Lo
3.34
- ON timer pre-operation at Auto fan for E9BKP
(H).
8
3.24
3.40
9
3.31
Me-
3.44
Me-
10
3.36
3.53
11
3.39
Me-
3.60
Me
- Powerful Mode at Lo fan for E123BKP (C).
12
3.44
3.63
13
3.47
Me
3.66
Lo
- Powerful Mode at Lo fan for E9BKP (C).
- ON timer pre-operation at Auto fan for E12BKP
(H).
14
3.55
Me
3.68
- Powerful Mode at Lo fan for E9BKP (H).
15
3.57
3.71
16
3.60
3.75
Me-
17
3.63
Me+
3.77
Me+
- Powerful Mode at Me- fan (C).
18
3.66
3.83
19
3.68
3.85
20
3.71
3.86
Me
- Powerful Mode at Lo fan for E12BKP (H).
21
3.73
Me+
3.91
- Powerful Mode at Me- fan for E9BKP (H).
22
3.77
3.94
23
3.79
3.98
Me+
- Powerful Mode at Me- fan for E12BKP (H).
24
3.80
4.00
25
3.82
Hi
4.00
Hi
- Powerful mode at Me, Me+ or Hi fan (C).
26
3.85
4.01
27
3.89
4.05
28
3.90
4.08
29
3.91
4.11
30
3.93
SHi
4.16
SHi
- Powerful mode at Me, Me+ or Hi fan (H).
31
4.07
4.30
21
CS-E9BKP CU-E9BKP5 / CS-E12BKP CU-E12BKP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
www.ilmalämpöpumput.com