background image

3

 

CAUTION

CAUTION

INDOOR UNIT AND OUTDOOR UNIT

Do not wash the indoor unit with water, benzene, thinner 

or scouring powder.
Do not use for other purpose such as preservation of 

food.
Do not use any combustible equipment in front of the 

air

fl

 ow outlet to avoid propagation 

fi

 re.

Do not expose yourself directly to cold air for a long 

period.
Do not sit or step on the unit, you may fall 

down accidentally.

Do not touch the sharp aluminium 

fi

 n, sharp 

parts may cause injury.

Do not switch ON the indoor unit when waxing the 

fl

 oor. 

After waxing, aerate the room properly before operating 

the unit.
Do not install the unit in oily and smoky areas.
Ensure drainage pipe is connected properly. Otherwise, 

leakage may occur.
Aerate the room regularly.
After long period of use, make sure the installation rack 

is not deteriorate to prevent the unit from falling down.

REMOTE CONTROL

Do not use rechargeable (Ni-Cd) batteries.

It may damage the remote control.

Remove the batteries if the unit is not going to be used 

for a long period of time.
New batteries of the same type must be inserted 

following the polarity stated to prevent malfunction of the 

remote control.

 

WARNING

WARNING

POWER SUPPLY

Do not use modi

fi

 ed cord, joint 

cord, extension cord or unspeci

fi

 ed 

cord to prevent overheating and 

fi

 re. 

Do not share the same power outlet with other 

equipment to prevent overheating and 

fi

 re.

Do not operate with wet hands to prevent electric shock.
If the supply cord is damage, it must be replaced by 

the manufacturer, its service agent or similarly quali

fi

 ed 

persons in order to avoid a hazard.
It is strongly recommended to be installed with Earth 

Leakage Circuit Breaker (ELCB) or Residual Current 

Device (RCD) to prevent electric shock or 

fi

 re.

This equipment must be earthed to prevent electrical 

shock or 

fi

 re.

Prevent electric shock by switching off the power supply 

when:

- Before cleaning or servicing.

- Extended non-use.

- Abnormally strong lightning activity.

INFORMATION

FOR SEASONAL INSPECTION AFTER EXTENDED NON-USE

•  Checking of remote control batteries.

•  No obstruction at air inlet and air outlet vents.

•  Use Auto OFF/ON button to select Cooling/Heating operation, after 

15 minutes of operation, it is normal to have the following temperature 

difference between air inlet and air outlet vents:

Cooling: 

 8°C 

Heating: 

 14°C

FOR EXTENDED NON-USE

•  Activate Heat mode for 2~3 hours as an alternative to remove moisture left in 

the internal parts thoroughly to prevent mould growth.

•  Turn off the power supply.

•  Remove the remote control batteries.

NON SERVICEABLE CRITERIAS

TURN OFF POWER SUPPLY then please consult 

authorized dealer under the following conditions:
•  Abnormal noise during operation.

•  Water/foreign particles have entered the remote 

control.

•  Water leaks from Indoor unit.

•  Circuit breaker switches off frequently.

•  Power cord becomes unnaturally warm.

•  Switches or buttons are not functioning properly.

Stop using the product when any

abnormality/failure occurs and disconnect 

the power plug or turn off the power switch 

and breaker.

(Risk of smoke/fi re/electric shock)

Examples of

Examples of

abnormality/

abnormality/

failure

failure

•  The ELCB trips frequently. 

•  Burning smell is observed.

•  Abnormal noise or vibration of the unit is 

observed.

•  Water leaks from the indoor unit. 

•  Power cord or plug becomes abnormally hot.

•  Fan speed cannot be controlled.

•  The unit stops running immediately even if it 

is switched on for operation.

•  The fan does not stop even if the operation 

is stopped.

Contact immediately your local dealer for 

maintenance/repair.

Summary of Contents for CS-E7LKR

Page 1: ...s Air Conditioner Model No Indoor Unit Outdoor Unit CS E7LKR CU E7LKR CS E9LKR CU E9LKR CS E12LKR CU E12LKR CS E15LKR CU E15LKR CS E18LKR CU E18LKR CS E21LKR CU E21LKR CS E24LKR CU E24LKR CS E28LKR CU E28LKR QUICK GUIDE QUICK GUIDE Before operating the unit read these operating instructions thoroughly and keep them for future reference ...

Page 2: ...shock or fire Do not install the unit in a potentially explosive or flammable atmosphere Failure to do so could result in fire Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit rotating parts may cause injury Do not touch the outdoor unit during lightning it may cause electric shock REMOTE CONTROL Do not allow infants and small children to play with the re...

Page 3: ...CB or Residual Current Device RCD to prevent electric shock or fire This equipment must be earthed to prevent electrical shock or fire Prevent electric shock by switching off the power supply when Before cleaning or servicing Extended non use Abnormally strong lightning activity INFORMATION FOR SEASONAL INSPECTION AFTER EXTENDED NON USE Checking of remote control batteries No obstruction at air in...

Page 4: ...mode To enjoy cool air Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode DRY mode To dehumidify the environment Unit operates at low fan speed to give a gentle cooling operation 4 TO SELECT FAN SPEED 5 OPTIONS FAN SPEED For AUTO the indoor fan speed is automatically adjusted according to the operation mode E7LKR E9LKR E12LKR E15LKR Remote Control dis...

Page 5: ...ld for 5 seconds to dim or restore the unit s indicator brightness 12 Press and hold for approximately 10 seconds to show temperature setting in C or F 13 Press to restore the remote control s default setting 14 Not used in normal operations E18LKR E21LKR E24LKR E28LKR MODE ON OFF SET CANCEL TIMER TEMP FAN SPEED MILD DRY QUIET POWERFUL 1 2 3 SET CHECK CLOCK RESET AC RC AIR SWING 6 7 TO MONITOR HUM...

Page 6: ...to avoid damage to the filter surface Dry the filters thoroughly under the shade away from fire or direct sunlight Replace any damaged filters 11 ACTIVE e ion GENERATOR Clean with dry cotton bud Active e ion generator cleaning is recommended every 6 months CAUTION Switch off the power supply before cleaning Do not touch the aluminium fin sharp parts may cause injury 5 ECO PATROL SENSOR Do not hit ...

Page 7: ... or replace the filters Clear any obstruction at the air inlet and air outlet vents Noisy during operation Check if the unit has been installed at an incline Close the front panel properly Remote control does not work Display is dim or transmission signal is weak Insert the batteries correctly Replace weak batteries The unit does not work Check if the circuit breaker is tripped Check if timers hav...

Page 8: ...mperature 3 Remote Control Preparation Remote Control Preparation 1 2 6 CANCEL TIMER ON OFF 1 2 SET 3 SET CHECK CLOCK RESET AC RC 3 4 5 1 Press and pull out 2 Insert AAA or R03 batteries can be used 1 year 3 Press CLOCK 4 Set time 5 Confirm 6 Close the cover Information for Users on Collection and Disposal of Old Equipment and used Batteries Information on Disposal in other Countries outside the E...