Front panel

Receiver

Auto OFF/ON button

•  Used when remote control is misplaced 

or malfunction.

Action

Mode

Press once.

Auto

Press and hold until 1 beep 

is heard, then release.

Cooling

Press and hold until 1 beep 

is heard, then release. 

Press again until 2 beeps, 

then release.

Heating

Press the button to turn off.

INDICATOR

e-ion AIR PURIFYING SYSTEM

 

Do not touch during operation

e-ion 

fi

 lters

Active e-ion Power 

Module

Active e-ion Generator

Maximum distances:  8m

Remote control 

display

TO TURN ON OR OFF THE UNIT

•  Please be aware of the OFF indication on the remote control 

display to prevent the unit from starting / stopping improperly.

 

TO SET TEMPERATURE

• Selection range: 16

˚

C ~ 30

˚

C.

•  Operating the unit within the recommended temperature could 

induce energy saving.

HEAT mode : 20

˚

C ~ 24

˚

C.

COOL mode : 26

˚

C ~ 28

˚

C.

DRY mode : 1

˚

C ~ 2

˚

C lower than room temperature.

TO SELECT OPERATION MODE

AUTO mode - For your convenience

•  Unit selects operation mode every 30 minutes according to 

temperature setting, outdoor and room temperature. During 

operation mode selection the power indicator blinks.

HEAT mode - To enjoy warm air

•  Unit takes a while to warm up. The power indicator blinks during 

this operation.

COOL mode - To enjoy cool air
DRY mode - To dehumidify the environment

•  Unit operates at low fan speed to give a gentle cooling operation.

Horizontal air

fl

 ow 

direction louver

• Manually 

adjustable.

Vertical air

fl

 ow 

direction louver

•  Do not adjust 

by hand.

(Green) (Orange) (Orange) (Orange)

(Blue)

(Blue)

Summary of Contents for CS-E15HKR

Page 1: ...Sdn Bhd 11969 T All rights reserved Unauthorized copying and distribution is a violation of law QUICK GUIDE QUICK GUIDE Before operating the unit read these operating instructions thoroughly and keep them for future reference Before operating the unit read these operating instructions thoroughly and keep them for future reference ...

Page 2: ...epair the unit by yourself Indoor Unit Do not install the unit in a potentially explosive atmosphere Do not wash the unit with water benzene thinner or scouring powder Do not use for other purposes such as preservation of food Do not use any combustible equipment in front of the airflow outlet Do not expose directly to cold air for a long period Ensure that the drainage pipe is connected properly ...

Page 3: ...reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Information for Users on Collection and Disposal of Old Equipment and used Batteries Information on Disposa...

Page 4: ...e unit from starting stopping improperly TO SET TEMPERATURE Selection range 16 C 30 C Operating the unit within the recommended temperature could induce energy saving HEAT mode 20 C 24 C COOL mode 26 C 28 C DRY mode 1 C 2 C lower than room temperature TO SELECT OPERATION MODE AUTO mode For your convenience Unit selects operation mode every 30 minutes according to temperature setting outdoor and ro...

Page 5: ...ress and hold for 5 seconds to dim or restore the unit s indicator brightness Press and hold for approximately 10 seconds to show temperature setting in C or F Press and hold for approximately 5 seconds to show 12 hour am pm or 24 hour time indication Press to restore the remote control s default setting Not used in normal operations Set the temperature 1 C higher in cool mode or 2 C lower in heat...

Page 6: ...ur nearest dealer for seasonal inspection CAUTION Switch off the power supply before cleaning Do not touch the aluminium fin sharp part may cause injury FOR SEASONAL INSPECTION AFTER EXTENDED FOR SEASONAL INSPECTION AFTER EXTENDED NON USE NON USE Checking of remote control batteries No obstruction at air inlet and air outlet vents After 15 minutes of operation it is normal to have the following te...

Page 7: ... stops occasionally during automatic fan speed setting This helps to remove the surrounding odours Operation is delayed a few minutes after restart The delay is a protection to the unit s compressor Outdoor unit emits water steam Condensation or evaporation occurs on pipes Timer indicator is always on The timer setting repeats daily once set Power indicator blinks during operation and the indoor f...

Page 8: ...mote Control Preparation Remote Control Preparation Matsushita Electric Industrial Co Ltd Web Site http www panasonic co jp global F566112 Printed in Malaysia OPTK0803 00 QUICK GUIDE QUICK GUIDE 1 Press and pull out 2 Insert AAA or R03 batteries can be used 1 year 3 Press CLOCK 4 Set time 5 Confirm 6 Close the cover ...