NON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY then please consult
authorised dealer under the following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the remote
control.
• Water leaks from Indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning properly.
9
English
To set the timer
Daily timer setting
To turn ON or OFF the unit at a preset time.
TIMER/CLOCK
CANCEL
CLOCK
SELECT
MODE
OFF/ON
SET
UP
DOWN
3
4
1
2
1
Press TIMER
MODE
to enter timer mode
• Press once to change the display from
clock to timer or vice-versa.
• Press for 4 seconds to change the display
from daily timer to weekly timer or vice-
versa.
2
Select ON or OFF
timer
Example:
OFF at 22:00
OFF/ON
3
Set the time
UP
DOWN
4
Con
fi
rm
SET
• To cancel, press
CANCEL
.
• When ON timer is set, the unit may start early
before the actual set time in order to achieve
the desired temperature on time.
• Timer operation is based on the clock set in
the remote control and repeats daily once set.
• The timer closest to the current time will be
activated
fi
rst.
• If timer is cancelled manually or due to power
failure, you can restore the previous setting
by pressing
SET
.
How to use / Information /
To
set the timer
To ensure optimal performance of the unit,
cleaning has to be carried out at regular
intervals. Please consult authorised dealer.
• Switch off the power supply before cleaning.
• Do not touch the aluminium
fi
n, sharp parts
may cause injury.
• Do not use benzine, thinner or scouring
powder.
• Use only soap ( pH 7) or neutral household
detergent.
• Do not use water hotter than 40 °C / 104 °F.
For seasonal inspection after extended
non-use
• No obstruction at air inlet and air outlet
vents.
• These units are mounted inside the ceiling.
It uses external air intake vent and air
outlet vent to operate. Please consult your
nearest dealer for seasonal inspection.
• After 15 minutes of operation, it is normal to
have the following temperature difference
between air inlet and air outlet vents:
COOL:
≥
8 °C / 14.4 °F
HEAT:
≥
14 °C / 25.2 °F
For extended non-use
• Activate HEAT mode for 2~3 hours to
remove moisture left in the internal parts
thoroughly to prevent mould growth.
• Turn off the power supply.
Summary of Contents for CS-E12QD3EAW
Page 44: ...44 8 R32...
Page 45: ...45 ELCB Earth Leakage Circuit Breaker RCD Residual Current Device ELCB...
Page 47: ...47 Ni Cd...
Page 84: ...84 R32 8...
Page 85: ...85 ELCB RCD ELCB...
Page 86: ...86 R32 A A A R22 R22 R32 R32 R410A R32 R410A R32 R410A R22 R32 R410A 12 7 1 2 R32 R410A...
Page 87: ...87 Ni Cd...