background image

8

Cleaning instructions

To ensure optimal performance of the unit, cleaning has to be carried out at regular intervals. 
Please consult authorised dealer.

• Switch off the power supply before cleaning.
• Do not touch the aluminium 

fi

 n, sharp parts may cause injury.

• Do not use benzine, thinner or scouring powder.
• Use only soap (  pH 7) or neutral household detergent.
• Do not use water hotter than 40 °C.

OPEN

CLOSE

CLOSE

OPEN

POW

ER

TIMER

AIR SW

ING

OFF/O

N

22

  

Slowly pull 

Slowly pull 

  down the 

 down 

the 

  intake grille.

 intake 

grille.

33

  

Remove the air 

Remove the air 

 

fi

 lter from the   

 

fi

 lter from the   

  tabs and pull it  

  tabs and pull it  

  downwards.

 downwards.

11

  

Press the knobs.

Press the knobs.

Remove

Remove

CLOSE

OPEN

OPEN

CLOSE

Remove Air Filter

Knob

Insert the air 

fi

 lter to the tabs 

of the intake 

grille. 

Slowly bring 

up the 

intake grille. 

Press the knobs to the 

CLOSE side.

Air Filter Installation

11

22

33

INDOOR UNIT

Wipe the unit gently 
with a soft, dry cloth.

AIR FILTER

Vacuum, wash and dry.

• lt is recommended to clean the air 

fi

 lter every 6 weeks.

• Do not operate without an air 

fi

 lter.

• Wash/rinse the air 

fi

 lter gently with 

water to avoid damage to the air 

fi

 lter 

surface.

• Do not dry the part with a hair dryer 

or a stove.

• Replace any damaged air 

fi

 lters.

For seasonal inspection after extended non-use

• Checking of remote control batteries.
• No obstruction at air inlet and air outlet vents.
• After 15 minutes of operation, it is normal to have the 

following temperature difference between air inlet and 
air outlet vents: 

COOL: 

8 °C

  

HEAT: 

14 °C

For extended non-use

• Activate HEAT mode for 2~3 hours to 

remove moisture left in the internal parts 
thoroughly to prevent mould growth.

• Turn off the power supply.
• Remove the remote control batteries.

F569176-SS0113-0_1EN.indd   8

F569176-SS0113-0_1EN.indd   8

17/04/2013   11:15:40

17/04/2013   11:15:40

Process Black

Process Black

AMP Air Conditioning

www.ampair.co.uk | [email protected]

Summary of Contents for CS-E12PB4EA

Page 1: ...ς Comment utiliser l appareil Climatiseur 42 49 Consultez un revendeur agréé pour connaître la validité de la connectivité Instrucciones de funcionamiento Climatizador de aire 50 57 Consulte a un distribuidor autorizado para conocer la validez de la conectividad Instruções de funcionamento Aparelho de ar condicionado 58 65 Consulte o representante autorizado para validar a conectividade Инструкции...

Page 2: ...ed on the first unit that turned on During operation HEAT and COOL modes cannot activate at the same time for different indoor units The power indicator blinks to indicate the indoor unit is standing by for a different operation mode Outdoor unit Indoor units Operation conditions Use this air conditioner under the following temperature range DBT Dry bulb temperature WBT Wet bulb temperature CU E9P...

Page 3: ...Y AUTO HEAT COOL 2 Start stop the operation POWER Please note that the OFF indication is on to start 3 Select the desired temperature Selection range 16 C 30 C Operating the unit within the recommended temperature may save energy HEAT 20 C 24 C COOL 26 C 28 C DRY 1 C 2 C lower than room temperature To dim or restore the unit s indicator brightness press and hold for 5 seconds Use remote control wi...

Page 4: ...ithout supervision Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handling will cause leakage electric shock or fire Confirm with authorised dealer or specialist on usage of any specified refrigerant type Using refrigerant type other than the specified may cause product damage burst and injury etc Do...

Page 5: ...ise equipment food animals plants artwork or other objects This may cause quality deterioration etc Do not use any combustible equipment in front of the airflow outlet to avoid fire propagation Do not expose plants or pet directly to airflow to avoid injury etc Do not touch the sharp aluminium fin sharp parts may cause injury Do not switch ON the indoor unit when waxing the floor After waxing aera...

Page 6: ...ower consumption during COOL mode use curtains to screen off sunlight and outdoor heat DRY To dehumidify the environment Unit operates at low fan speed to give a gentle cooling operation POWERFUL QUIET To switch between powerful quiet QUIET POWERFUL NORMAL POWERFUL To reach temperature quickly POWERFUL Single This operation stops automatically after 20 minutes Multi Press the button again or turn ...

Page 7: ...ple OFF at 22 00 Each time pressed OFF Cancel 2 Set the time 2 3 Confirm SET TIMER To cancel ON or OFF timer press ON or OFF to select respective or then press CANCEL If timer is cancelled manually or due to power failure you can restore the timer again by pressing ON or OFF to select respective or then press SET The nearest timer setting will be displayed and will activate in sequence When ON Tim...

Page 8: ...bs to the CLOSE side Air Filter Installation 1 1 2 2 3 3 INDOOR UNIT Wipe the unit gently with a soft dry cloth AIR FILTER Vacuum wash and dry lt is recommended to clean the air filter every 6 weeks Do not operate without an air filter Wash rinse the air filter gently with water to avoid damage to the air filter surface Do not dry the part with a hair dryer or a stove Replace any damaged air filte...

Page 9: ...utlet vents Noisy during operation Check if the unit has been installed at an incline Close the intake grille properly Remote control does not work Display is dim or transmission signal is weak Insert the batteries correctly Replace weak batteries The unit does not work Check if the circuit breaker is tripped Check if timers have been set The unit does not receive the signal from the remote contro...

Page 10: ...13 Authorised representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg Germany F569176 SS0113 0_1EN indd 80 F569176 SS0113 0_1EN indd 80 17 04 2013 11 15 46 17 04 2013 11 15 46 Process Black Process Black AMP Air Conditioning www ampair co uk sales ampair co uk ...

Reviews: