background image

CAUTION

Two or more people must lift and
transport the product. 

• Avoid personal injury. 

Do not install the product where it will be
exposed to sea wind (salt spray) directly.

• It may cause corrosion on the product. 

Install the drain hose to ensure that the
condensed  water is drained away properly. 

• A bad connection may cause water leakage.

Keep level even when installing the
product.

• To avoid vibration or noise.

Do not install the product where the noise
or hot air from the outdoor unit could
damage or  disturb the neighborhoods.

• It may cause a problem for your neighbors

and hence dispute.

Always check for gas (refrigerant)
leakage after installation or repair of
product.

• Low refrigerant levels may cause failure of

product.

Indoor/outdoor wiring connections must
be secured tightly and the cable should
be routed properly so that there is no
force pulling the cable from the
connection terminals.

• Improper or loose connections can cause

heat  generation or fire.

Safely dispose off the packing materials.
Like screws, nails, batteries, broken
things etc after installation or svc and
then tear away and thraw away the plastic
packaging bags.

• Children may play with them and cause

injury.

Make sure to check that the power cable
plug is not dirty, loose or broken  and
then only insert the plug completely.

• Dirty, loose or broken power plug can

cause electric shock or fire.

Do not use the product in a tightly closed
space for a long time. Perform ventilation
regularly.

• Oxygen deficiency could occur and hence

harm your health.

Do not open the front  grille of the product
during operation. (Do not touch the
electrostatic filter, if the unit is so equipped.) 

• There is risk of physical injury, electric shock,

or product failure.

If strange sounds, smell or smoke comes
from product.Immediately turn the breaker
off or disconnect the power supply cable.

• There is risk of electric shock or fire.

Ventilate the product room  from time to
time when operating it together with a
stove, or heating element etc.

• Oxygen deficiency can occur and hence harm

your health.

Turn the main power off and unplug the
unit when cleaning or repairing the
product. 

• There is risk of electric shock.

When the product is not to  be used for a
long time, disconnect the power supply
plug or turn off the breaker.

• There is risk of product damage or failure, or

unintended operation.

Take care to ensure that nobody
especially kids could step on or fall onto
the outdoor unit. 

• This could result in personal injury and

product damage. 

Take care to ensure that power cable
could not be pulled out or damaged
during operation.

• There is risk of fire or electric shock.

Do not place ANYTHING  on the power
cable.

• There is risk of fire or electric shock.

Do not plug or unplug the power supply plug to turn the unit
ON/OFF .

• There is risk of fire or electric shock.

When flammable gas leaks, turn off the gas and open a window
for ventilation before turn the product on. 

• Do not use the telephone or turn switches on or off. There is risk of

explosion or fire.

In outdoor unit the step-up capacitor
supplies high voltage electricity to the
electrical components. Be sure to
discharge the capacitor completely
before conducting the repair work.

• An charged capacitor can cause electrical

shock.

When installing the unit, use the
installation kit provided with the product.

• Otherwise the unit may fall and cause severe

injury.

Be sure to use only those  parts which
are  listed in the svc  parts list. Never
attempt to modify the equipment. 

• The use of inappropriate parts can cause an

electrical shock, excessive heat generation or
fire.

4

Summary of Contents for CS-D56JD1F5

Page 1: ...thorized copying and distribution is a violation of law MFL62048502 CU D56JD1F8 CS D56JD1F5 Please read these operating instructions carefully and thoroughly before installing and operating your air conditioner Please retain these operating instructions for future reference after reading them thoroughly IMPORTANT ...

Page 2: ...e authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should be supervised to ensure that they do not play with the air conditioner When the power cord is to be replaced replacement work shall be performed by authorized pe...

Page 3: ...and earth leakage current breaker 3 ...

Page 4: ...ectric shock or product failure If strange sounds smell or smoke comes from product Immediately turn the breaker off or disconnect the power supply cable There is risk of electric shock or fire Ventilate the product room from time to time when operating it together with a stove or heating element etc Oxygen deficiency can occur and hence harm your health Turn the main power off and unplug the unit...

Page 5: ...OPERATING TEMPERATURE C COOLING MODE R O O D T U O R O O D N I N I M X A M N I M X A M 1 2 3 2 4 C 5 C 10 C C 5 ...

Page 6: ...ntroller 4 Inlet air 5 Discharge air 6 Refrigerant piping connection electric wire 7 Drain pipe 8 Ground wire wire to ground outdoor unit to prevent electrical shocks 6 7 2 8 4 5 Remote Controller 3 Air intake vents 1 Air outlet vents Name and function of parts 6 ...

Page 7: ... source OPERATION INDICATION SCREEN SET TEMPERATURE Button VENTILATION Button OPERATION MODE SELECTION Button SUBFUNCTION Button FUNCTION SETTING Button EXIT Button ON OFF Button ROOM TEMPERATURE Button FAN SPEED Button AIR FLOW Button RESERVATION TIME SETTING Button SETTING CANCEL Button UP DOWN LEFT RIGHT Button RESET Button 1 2 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 7 6 5 3 15 14 13 12 11 10 9 8...

Page 8: ... operation mode 2 Adjust the desired temperature by pressing buttons Press button to check the Room temperature When setting the desired temperature higher than room temperature only ventilation wind is blow out instead of cooling wind 3 Operating Instructions Setting Temp Range 18 C 30 C 64 F 86 F 8 ...

Page 9: ...ts depends on products function NONE Power level of Fan Speed 3 In rainy season or high humidity climate it is possible to operate simultaneously dehumidifier and cooling mode to remove humidity effectively Press button to turn on the indoor 1 Press button to select Auto Changeover Mode 2 The setting temperature as the right side picture can be set in both cooling heating model 3 Auto Changeover M...

Page 10: ... button 2 Press the button to select airflow rate SLO LO MED HI NONE 3 The lists depends on products function When operating in wind mode the outdoor compressor doesn t work FAN operation doesn t bring out cold air but air from regular fan comes out 10 ...

Page 11: ...erature can be adjusted at 0 5 C or 1 F Cooling operation The cooling mode doesn t work if desired temperature is higher than room temperature Please lower the desired temperature Heating operation The heating mode doesn t work if desired temperature is lower than room temperature Please increase the desired temperature 1 Whenever press button the room temperature will be displayed within 5 second...

Page 12: ... it will reduce cooling heating efficiency and accumulate more electric power Therefore do clean the filter whenever cleaning time is expired Function setting Filter Sign Clear Press button Repeat pressing button until the icon flash 1 When the flashing press the button to clear this display 2 12 ...

Page 13: ...icon flash When the button flashing press button to set this function When setting this function icon will be displayed whenever entering any operation except for Room temperature access However it is possible to control normally by wireless remote controller To release this setting keep pressing button until icon flash and then enter button 13 ...

Page 14: ...x Setting ACO Temp as 3 2 Press button to change converting temp value 1 7 3 Press button to complete and active the setting process 4 Press button to exit or system will automatically release without any input after 25 seconds 5 This function is to set converting temp of Auto Changeover 14 ...

Page 15: ...g Current Time as Monday AM 10 20 1 Press key to adjust the current day 2 Press key to move to AM PM setting mode the AM PM segment will flash 3 Setting AM PM value by pressing button 4 Press button to move to Hour setting mode the Hour segment will flash 5 Setting Hour value by pressing button 6 15 ...

Page 16: ...Minute segment will flash 7 Setting Minute value by pressing button 8 Press button to finish 9 In the process press button to release and exit from setting mode In case of exit with incomplete information it will return to the previous setting 10 16 ...

Page 17: ...finish setting 3 Adjusting the reservation time after finish reservation setting will release the previous one 4 In case of there is not any reservation setup on system it is possible to make a SIMPLE reservation on indoor unit If the indoor is ON we can make the reservation for turning OFF In reserve if the indoor is OFF we can set the timer for turning ON The reservation time is from 1 to 7 hour...

Page 18: ...reservation time is from 1 to 7 hours 3 Press button to finish setting Whenever reservation is done icon will flash When this setting is released icon will disappear 4 Adjust the reservation time after finish reservation setting will release the previous one 5 This function is able to turn off Air conditioner when sleeping or after some hours Please set a suitable time for sleep reservation turnin...

Page 19: ... button to adjust AM PM setting 3 Press button to Hour setting mode When the Hour icon flash please setting time The setting range is within 1 12 4 Press button to shift to Minute setting mode When the Minute icon flash please setting minute the setting range is within 00 59 5 Press button to finish setting 6 This function is able to turn air conditioner ON after a setting time 19 ...

Page 20: ...ton to adjust AM PM setting 3 Press button to shift to Hour setting mode When the Hour icon flash please setting time The setting range is within 1 12 4 Press button to shift to Minute setting mode When the Minute icon flash please setting minute the setting range is within 00 59 5 Press button to finish setting 6 This function is able to turn air conditioner OFF after a setting time 20 ...

Page 21: ...Press left right button to adjust the current day 2 Press up down button to adjust the action number 3 Press right button to move to Hour Part on ON Time section The Hour segment will be flashed 4 Press right button to move to Minute Part on Start time section The Minute segment will be flashed 6 Press up down button to adjust the Hour on Start Time section 5 Start Time Section The weekly reservat...

Page 22: ...ncel button to complete programming The under bar segment will be created when it finished 10 Please refer the process from No 2 to No 10 for setting other day weekly program It is same method 11 Press exit button to exit or system will automatically release without any input after 25 seconds 12 Off Time Section Description of weekly reservation Start Time Section Off Time Section Note Action Star...

Page 23: ...t or release a selected day as holiday or not the holiday is indicated with a underline 4 If there is any holiday from Monday to Sunday segment on LCD will be displayed 5 Press the button to exit or if there is not any input system will release any setting after 10 seconds 6 It is possible to set the air conditioner OFF in every holiday ex 9 00 10 00 13 00 7 This function is to automatically stop ...

Page 24: ...e error occurred in the indoor unit then the error code will be displayed on remote controller CH and error code number is displayed at regular intervals When the remote controller is used in Group Control the error code will be displayed as shown below CH and error code number is displayed at regular intervals beside the Clock as shown in figure Ex In case of CH03 24 ...

Page 25: ...arts of the indoor unit It may cause an injury 2 Clean dirt from the air filter using a vacuum cleaner or washing with water If dirt is conspicuous wash with a neutral detergent in lukewarm water If hot water 50 C or more is used it may be deformed 3 After washing with water dry well in the shade Do not expose the air filter to direct sunlight or heat from a fire when drying it 4 Install the air f...

Page 26: ...indows are kept closed it is a good idea to open them and ventilate the room from time to time When it is not going to be used for a long time 1 Operate the air conditioner on Air circulation mode for 2 to 3 hours This will dry out the internal parts 2 Turn off the circuit breaker CAUTION Turn off the circuit breaker when the air conditioner is not going to be used for a long time Dirt may collect...

Page 27: ...n very hot when the room air conditioner was first turned on Allow time for it to cool down Has the setting temperature been set incorrectly Are the indoor unit s air inlet or outlet vents obstructed For a noise that sounds like water flowing This is the sound of freon flowing inside the air conditioner unit For a noise that sounds like the compressed air releasing into atmosphere This is the soun...

Page 28: ...Printed in China Panasonic Corporation Website http panasonic net MFL62048502 ...