background image

2

ENGLISH

Safety Precautions

Do not install, remove and reinstall the unit yourself.
Improper installation will cause leakage, electric shock or fire. Please engage an authorized dealer or
specialist for the installation work.

Warning

To prevent personal injury, injury to others and property damage, the following instructions must be followed.

Incorrect operation due to ignoring of instructions will cause harm or damage, the seriousness of which is
classified as follows :

Caution

Warning :

This sign warns of death or serious injury.

This sign warns of injury or damage to property only.

This symbol (with a white background) denotes an action that is
PROHIBITED.

These symbols (with a black background) denote an action that is
COMPULSORY.

The instructions to be followed are classified by the following symbols :

!

!

!

!

Installation precautions

Before operating, please read the following “Safety Precautions” carefully.

This room air conditioner must be earthed.

Improper grounding could cause
electric shock.

Do not install the unit in a place where there
may be explosive gas leaks.

Gas leaks near the unit could cause
fires.

Ensure that drainage piping is connected
properly.

Otherwise, water will leak out.

Caution :

OFF

Summary of Contents for CS-C182KR

Page 1: ...ner Operating Instructions ENGLISH P 1 P 22 Before using your air conditioner please read this operating instructions carefully and keep it for future reference Outdoor Model CU C182KR CU C242KR Indoor Model CS C182KR CS C242KR ...

Page 2: ... 9 10 Setting the Timer 11 12 Convenient Operation 13 14 Sleep mode When remote control cannot be used OFF ON remote control signal receiving sound Operation Hints 15 16 Better Care and Maintenance 17 18 Cleaning the air conditioner and air filters Cleaning of front panel Replacement of air purifying filters When not using the air conditioner for a long period Pre season inspection Troubleshooting...

Page 3: ...arns of death or serious injury This sign warns of injury or damage to property only This symbol with a white background denotes an action that is PROHIBITED These symbols with a black background denote an action that is COMPULSORY The instructions to be followed are classified by the following symbols Installation precautions Before operating please read the following Safety Precautions carefully...

Page 4: ...hock or fire Do not operate the unit with wet hands It could cause an electric shock If there is a smell of burning stop the air conditioner and disconnect the power supply The heat generated could cause electric shock or fire Please con sult an authorized dealer or service centre Warning Do not damage or use an unspecified power cord It will cause electrical shock or fire Do not insert finger sti...

Page 5: ...om regularly Since windows are kept closed it does good to open them periodi cally to ventilate the room Do not sit or place anything on the outdoor unit You might fall off or the unit might collapse Switch off the power supply if the unit is not going to be used for a long period of time If dust accumulates on the plug it will generate heat and this could cause a fire Do not place combustor in th...

Page 6: ...ration Indication Lamps LED Test Run Button Panel Opener Horizontal Airflow Direction Louver Manually adjusted Vertical Airflow Direction Louver Signal Receptor Power Switch Power Supply Cord Auto Operation Button Air Outlet Vents Drain Hose Piping Rear Side Outdoor unit Ground Terminal Inside cover Air Intake Vents ...

Page 7: ...M M O D E T E M P F A N S P E E D M A N U A L S W I N G A I R S W I N G FAN DRY COOL A U T O A M ON TIMER OFF TIMER C A U T O F A N c h j k m n o Airflow Direction Auto Control Button OFF Timer Button ON Timer Button Set Button Cancellation Button Clock Button Time Button q OFF TIMER ON TIMER CANCEL SET TIME Door Operation Mode Selection Button Room Temperature Setting Button Sleep Mode Operation ...

Page 8: ...ise up slightly and then pull down 2 3 4 Hold the panel openers at both sides and pull up the front panel Air filter Be careful not to hurt your hands by metal parts 2 1 1 Air purifying filter Connect the power supply cord to an independent power supply Use the air conditioner under the following conditions Unit in C DBT Dry Bulb Temp WBT Wet Bulb Temp Maximum Temperature Minimum Temperature Indoo...

Page 9: ...r switch is left at I ON approximately 3 25 watts of electric power are used even if the main unit is turned off by remote control There is a danger of lightning The air conditioner is provided with a built in protective device but the control equipment may be adversely affected depending on the extent of lightning activity Regarding the batteries The batteries can be used for approximately one ye...

Page 10: ...eration will be automatically restarted with previous operation mode and airflow direction Note 1 If you do not require Auto Restart Control please consult your dealer 2 Auto Restart Control is not available when Timer or Sleep Mode is set Auto Restart Control For Cooling 26 C 28 C For Soft Dry 1 C 2 C lower than room temperature Cooling operation until room tem perature reaches the setting temper...

Page 11: ...han standard 1 2 3 4 5 Press to select operation mode The display changes in the order AUTO COOL DRY FAN each time the button is pressed Press to start the operation Operation indication lamp RED will light up Press once more to stop the operation Press to select airflow volume The display changes in the order AUTO FAN Automatic Low Medium High Press to select room temperature Cooling Soft Dry Air...

Page 12: ...itch is used when two air conditioners units have been installed in one room Please consult your dealer OPEN RESET points Setting the Timer B A switch If there is a power failure OFF TIMER SET To reset the Timer Example If the OFF Timer has been set Even if there is a power failure the setting time is still stored in the memory because the remote control is a battery operated type q OFF ON SLEEP P...

Page 13: ...imer Set hours and minutes The OFF TIMER will blink ON Timer Set hours and minutes The ON TIMER will blink To cancel the Timer OFF Timer To change the Timer setting time Example To change the ON Timer setting time Change hours and minutes setting TIME to advance the time to reverse the time to increase 10 minutes each step to decrease 10 minutes each step TIME The Timer indication lamp at main uni...

Page 14: ...ormation Cooling or Soft Dry Operation for Sleep Mode movement will start to avoid overcooling To set Sleep Mode Press The sleep indication lamp on the main unit will light up To cancel Sleep Mode Press once more The sleep indication lamp on the main unit will switch off Approx 0 5 C increase Approx 0 5 C increase 1 hour 0 1 hour Approx 8 hours after sleep shift operation starts stops automati cal...

Page 15: ...g sound can be omitted as desired To switch OFF the signal receiving sound press Auto Operation Button for 10 seconds or more At the same time Automatic Operation starts To switch ON press Auto Operation Button once more for 10 seconds or more Press Auto Operation Button The operation indication lamp will blink for 20 seconds and then light up If the button is pressed once more the air conditioner...

Page 16: ...with the Timer Use Timer when sleeping or going out to save electricity cost Clean the air filter regularly Blockage in the air filter reduces the airflow and lowers the cooling Clean at least once every 2 weeks Otherwise about 6 of electricity cost will be wasted Do not block the air outlet vents at outdoor unit Otherwise it will lower the cooling perform ance 1 C higher ...

Page 17: ...tment Set the air flow direction louvers horizontal for Cooling Operation Operation result will be better Keep blinds or curtains closed Do not let sun shine enter the room directly About 5 of elec tricity cost can be saved Use insulating material for better performance Use insulating material during construction or renovations It will save electricity cost Cooling ...

Page 18: ...ilters become damage Air Filter No CWD00231 right CWD00232 left Regular care and maintenance will extend the life of the air conditioner and prevent wastage of electricity Before performing any maintenance procedure be sure to switch off the main power supply Once every 2 weeks is recommended To clean the front panel gently wash with sponge Wipe dry or dry in shade IMPORTANT It may lead to shaft d...

Page 19: ...d cause problems If display is faint or no display is visible the batteries should be replaced Caution Be careful not to hurt your hands on metal parts If it is leaks will result Remove the air purifying filters Remove the filters from the filter frame Remove the air filters Remove the batteries from the remote control 2 1 Operate the air condi tioner for 2 to 3 hours Type of operation Fan 3 2 1 F...

Page 20: ...r flowing can be heard This is the sound of refrigerant flowing inside the air conditioner unit It seems that fog is coming out from the air condi tioner Condensation occurs when the airflow from the air conditioner cools the room air During Automatic Airflow Volume setting indoor fan stops occasionally This is to remove the smell exuded by the surroundings Soft Dry Mode Operation is a very gentle...

Page 21: ...ncorrectly Are the filters dirty Are the intake or outlet vents of the outdoor unit obstructed Are all windows and doors closed Is the installation work slanted Is the front grille closed properly Call the dealer immediately Abnormal noise is heard during operation Water or foreign material gets into the remote control by mistake Water leaks from the indoor unit If the following conditions occur i...

Page 22: ...HE SUPPLY SOCKET WHEN NOT IN USE WHERE SUPPLY CONNECTION IS VIA MAINS PLUG IMPORTANT 1 WHEN THE POWER CORD IS CONNECTED TO THE MAINS THROUGH A MULTI POLAR SWITCH THERE MUST BE A MULTI POLAR SWITCH DISCONNECTING MEANS WITH A MINIMUM 3 mm CONTACT GAP IN THE FIXED INSTALLATION CIRCUIT 2 WHEN THE POWER PLUG IS CONNECTED TO THE RECEPTACLE Replacement or installation of power plugs shall be performed on...

Page 23: ... 22 ENGLISH Please remember to record the following Model Number Serial Number Dealer s Name Date Purchased Note ...

Page 24: ...Matsushita Electric Industrial Co Ltd Osaka 542 8588 Japan Printed in Malaysia P0103 0 F563263 ...

Reviews: