![Panasonic CS-A12CTP Service Manual Download Page 24](http://html.mh-extra.com/html/panasonic/cs-a12ctp/cs-a12ctp_service-manual_256565024.webp)
Heating in operation according to Remote Control setting.
Time Delay Safety Control
30 minutes Time Save Control
Overload Protection Control
Compressor Reverse Rotation Protection Control
7.3. Heating Mode Operation
•
When the compressor is stopped by Remote Control, it restarts after 3 minutes when the Remote Control is turned ON.
•
When the setting temperature is reached during heating operation, the compressor stops and it will not start for 4 minutes.
•
The compressor will start automatically if it has stopped for 30 minutes even if the room temperature is between the compressor
ON temperature and OFF temperature.
(a) Outdoor Fan Control
•
A12CT
If the temperature of the indoor heat exchanger rises to 51°C, Outdoor Fan stops.
The Outdoor Fan restarts when the indoor heat exchanger temperature falls to 49°C.
•
A18CT, A24CT
If the temperature of the Outdoor Heat Exchanger less than -3°C, Outdoor Fan is ON. The Outdoor Fan stop, when Outdoor
Heat Exchanger temperature is T
b
or more according to Outdoor Air Temperature region as table below:
The Outdoor Fan restarts when the indoor heat exchanger temperature falls to 49°C.
During starting of Heating mode and after deice, Outdoor Fan ON for 90 sec.
(b) Compressor high pressure protection
•
If the indoor heat exchanger becomes 65°C (A12CTP); 68°C (A18CTP & A24CTP) or more, the compressor will stop and
restart automatically.
(Time Delay Safety Control - 4 minutes waiting).
•
If the compressor is operating continuously for 5 minutes or longer and temperature difference between intake air and indoor
heat exchanger is 5°C or less for 2 minutes, compressor will stop and restart automatically.
(Time Delay Safety Control is valid).
▲
T = Indoor heat exchanger temperature - intake air temperature.
This is to protect reverse rotation of the compressor when there is a instantaneous power failure.
24
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5
Summary of Contents for CS-A12CTP
Page 11: ...3 Dimensions 11 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Page 12: ...12 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Page 14: ...14 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Page 15: ...5 Block Diagram 15 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Page 16: ...16 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Page 17: ...6 Wiring Diagram 17 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Page 18: ...18 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Page 53: ...12 Technical Data 53 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Page 55: ...13 Exploded View 55 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Page 71: ...19 1 REMOTE CONTROL 71 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Page 73: ...73 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 MAICO Printed in Malaysia ...