Installation Precautions

!

 Warning

This room air conditioner must be
earthed.

Improper grounding could cause
electric shock.

Ensure that the drainage piping is
connected properly.

Otherwise, water will leak out.

Do not install the unit in a
potentially explosive atmosphere.

Gas leak near the unit could cause
fire.

Do not install, remove and reinstall the unit by
yourself.

Improper installation will cause leakage, electric
shock or fire. Please engage an authorized dealer
or specialist for the installation work.

!

 Caution

OFF

OFF

Operation Precautions

!

 Warning

This sign warns of death or serious injury.

Do not share outlet.

Do not insert plug to operate the unit. Do not
pull out plug to stop the unit.

Do not operate with wet hands.

Do not damage or modify the power cord.

Do not insert finger or other objects into the
indoor or outdoor units.

Do not expose directly to cold air for a long period.

Plug in properly.

Use specified power cord.

If abnormal condition (burnt smell, etc.)
occurs, switch off and unplug the power
supply.

!

 Caution

This sign warns of injury.

Do not pull the cord to disconnect the plug.

Do not wash the unit with water.

Do not use for other purposes such as
preservation.

Do not use any combustible equipment at
airflow direction.

Do not sit or place anything on the outdoor unit.

Switch off the power supply before cleaning.

Ventilate the room regularly.

Pay attention as to whether the installation
rack is damaged after long period of usage.

Switch off the power supply if the unit is not
used for a long period.

SAFETY PRECAUTIONS

Before operating, please read the following
“Safety Precautions” carefully.

To prevent personal injury, injury to others and
property damage, the following instructions must be
followed.

Incorrect operation due to failure to follow instructions
will cause harm or damage, the seriousness of which
is classified as follow:

!

 Warning

This sign warns of death or serious injury.

!

 Caution

This sign warns of damage to property.

The instructions to be followed are classified by the
following symbols:

This symbol (with a white background) denotes an

action that is PROHIBITED.

These symbols (with a black background) denote

actions that are COMPULSORY.

OFF

Summary of Contents for CS-A12ATP5

Page 1: ... CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ENGLISH P 1 P 9 F563422 Before using your air conditioner please read this operating instructions carefully and keep it for future reference OPERATING INSTRUCTIONS Room Air Conditioner ...

Page 2: ...milarly qualified person in order to avoid a hazard 2 Remove power plug or disconnect from the main before servicing this appliance 3 Do not repair by yourself In case of malfunction of this appliance do not repair by yourself Contact the sales dealer or service dealer for a repair 4 The appliance is not intended for use by young children or infirm persons without supervision 5 Young children shou...

Page 3: ...ch off and unplug the power supply Caution This sign warns of injury Do not pull the cord to disconnect the plug Do not wash the unit with water Do not use for other purposes such as preservation Do not use any combustible equipment at airflow direction Do not sit or place anything on the outdoor unit Switch off the power supply before cleaning Ventilate the room regularly Pay attention as to whet...

Page 4: ...2 Power Indicator GREEN 3 Timer Mode Indicator ORANGE 4 Air Swing Mode Indicator RED 5 Sleep Mode Indicator ORANGE Outdoor Unit 1 Air Intake Vents 2 Piping 3 Drain Hose 4 Connecting Cable 5 Air Outlet Vents Accessories Remote Control Remote Control Holder Two RO3 AAA dry cell batteries or equivalent OFF O N TEMP MODE FA N SP EE D AU TO TIMER AIR SW ING ON OFF SE T C MAN UA L RE SE T SL EE P AU TO ...

Page 5: ...be used for a long period Proper way to operate the remote control in the case of ceiling wall mounting Operate the remote control in parallel with the floor See the figure below 1 Signal Transmitter 2 Operation Display 3 Room Temperature Setting Button self illuminating button 4 Operation Mode Selection Button 5 Sleep Mode Operation Button self illuminating button 6 Timer Setting Button 7 Timer S...

Page 6: ...AUTO Operation press 3 to select Operation with 2 C higher than the standard temperature Operation with the standard temperature Operation with 2 C lower than the standard temperature Standard Temperature At the beginning of the automatic operation Heating Cooling or Soft Dry is automatically selected according to the indoor temperature After the operation mode has been selected the mode does not ...

Page 7: ...adjusted as desired by using the remote control This is effective when you want to cool yourself directly such as when coming out of the bath The louver can be adjusted within a range between the horizontal and 30 degrees downward at Cooling and Soft Dry Operation and between the horizontal and 60 degrees downward at Heating Operation Automatic Operation Press the Auto Airflow Direction Button 6 C...

Page 8: ... press the Timer Setting Button 2 or 3 to the desired number of hours Press the Timer Set Cancel Button 4 1 hour Sleep shift operation starts Approx 3 C decrease Cooling or Soft Dry Operation for sleep shift operation will start to avoid overcooling Heating operation for sleep shift operation will start to avoid overheating Sleep Operation button is pressed 0 1 hour Approx 2 C decrease Approx 1 C ...

Page 9: ...y once the Auto operation button is pressed However temperature cannot be adjusted in this operation The power indicator on the indoor unit will blink until the operation mode is selected automatically To cancel this operation press once more Timer Setting When power failure occurs the timer setting will be cancelled Once power is resumed reset the timer Thunder and Lightning This air conditioner ...

Page 10: ...is the answer This is to protect the air conditioner Wait until the air conditioner begins to operate This is the sound of refrigerant flowing inside the air conditioner Condensation occurs when the airflow from the air conditioner cools the room This may be a damp smell emitted by the wall carpet furniture or clothing in the room In COOL DRY operation moisture in the air condenses into water on t...

Page 11: ...ita Electric Industrial Co Ltd Web Site http www panasonic co jp global F563422 Printed in Malaysia P0112 2 Please remember to record the following Model Number Serial Number Dealer s Name Date Purchased Note ...

Reviews: