Operation Details
COOL – Cooling Operation
•
To set the room temperature at your preference
cooling comfort.
AUTO – Automatic Operation
•
Sense indoor temperature to select the optimum
mode.
•
Temperature is not displayed on the remote control
during AUTO operation.
DRY – Soft Dry Operation
•
A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.
•
During Soft Dry operation, the indoor fan operates at
Low Fan Speed for 10 minutes (ON and OFF for 4
seconds intervals) then OFF for 6 minutes. This
operation will be repeated.
HEAT – Heating Operation
(for Heat Pump Model only)
•
Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
falls, the heating capacity of the unit might be
reduced.
•
Defrosting Operation
Depend on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
unit.
FAN – Air Circulation Operation
(for Cooling Model only)
•
Heated air rises and collects at the top of the room.
The air circulation circulates the heated air downward,
thus increasing heating effectiveness. When the unit
is installed floor mounted, you should set the
temperature higher than that of ceiling mounted.
■
Setting the Fan Speed
• Press
4
to select:-
– Low Fan Speed
– Medium Fan Speed
– High Fan Speed
■
Vertical Airflow Direction
●
Manual Operation
• Press and hold the Manual Airflow Direction
Selection Button
5
, then release at the desired
airflow direction.
• Cooling / Soft Dry / Heating
The airflow direction can be adjusted as desired
by using the remote control. This is effective
when you want to cool yourself directly, such as
when coming out of the bath. The louver can be
adjusted within a range between the horizontal
and 30 degrees downward at Cooling and Soft
Dry Operation, and between the horizontal and
60 degrees downward at Heating Operation.
●
Automatic Operation
• Press the Auto Airflow Direction Button
6
.
• Cooling / Soft Dry
The louver will automatically swing up and down
to create the feeling of a refreshing breeze.
• Heating
■
Setting the Horizontal Airflow Direction
●
Use this air conditioner under the following
conditions:
Cooling Model
• Adjust it manually
●
Notes
•
If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.0 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.
•
If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
Maximum Temperature-Cooling
(Maximum Temperature-Heating)
Minimum Temperature-Cooling
(Minimum Temperature-Heating)
DBT
32
(30)
16
(16)
WBT
23
(-)
11
(-)
DBT
43
(24)
16
(-5)
WBT
26
(18)
11
(-6)
Indoor
Outdoor
(Unit in °C)
Heat Pump Model
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
Maximum Temperature
Minimum Temperature
DBT
32
20
WBT
23
14
DBT
43
20
WBT
26
14
Indoor
Outdoor
(Unit in °C)
Downward
Swing up
and down
Horizontal
When the airflow
temperature is low
Downward
When the airflow
temperature become warm
Horizontal
At ceiling mounted
At floor mounted
OF
F/O
N
TE
MP
MO
DE
FAN SPEED
AU
TO
TIM
ER
AIR
SW
ING
ON
/OFF
SET/C
RES
ET
AU
TO
CO
OL
FA
N
FA
N
SP
EE
D
DR
Y
C
H
H
O
FF
O
N
O
FF
O
N
SLEEP
3
2
1
4
5
CONVENIENCE OPERATION
■
Sleep Mode Operation
To obtain a comfortable room temperature while
sleeping:-
• Press
5
.
• Sleep mode indicator on the indoor unit will light up.
• To cancel this operation, press once more.
●
Sleep Mode Operation Details
• When the room temperature reaches the set
temperature, the airflow volume will change to low
automatically.
• Sleep Mode Operation time is 5 hours.
• When used together with the timer, the timer has a
priority.
Cooling Model
CARE AND MAINTENANCE
■
Cleaning the Indoor Unit and Remote
Control
• Wipe gently with a soft, dry cloth.
• Do not use water hotter than 40˚C or polishing fluid
to clean the unit.
■
Cleaning the Air Filter
(Recommendation:- If the unit is operated in a dusty
environment, clean the filters every two weeks,
continuous use of this dirty filters will reduce cooling
or heating efficiency)
1
Remove dirt using a vacuum cleaner.
2
Wash back of the air filter with water.
3
If badly soiled, wash it with soap or a mild household
detergent.
4
Let it dry and reinstall it.
Be sure the “FRONT” mark is facing you.
*
Damaged air filter.
Consult the nearest authorized dealer.
Part No.: CWD00112.
• Do not use benzene, thinner, scouring powder or
clothes soaked in caustic chemical to clean the
unit.
H
OFF
H
ON
H
ON
H
OFF
H
ON
H
OFF
SETTING THE TIMER
The Delay ON-Timer and Delay OFF-Timer cannot be
selected simultaneously.
• Press the Timer Selection Button
1
.
• Select one of the following five types of operation.
Each time the button is pressed, the operation mode
is shifted in the arrow direction.
Delay OFF Timer
Example :
Operation Stops
after 1 hour
ON Timer.
Delay ON Timer
Example :
Operation starts after
6 hours.
Delay OFF and
Example :
ON Timer
Operation stops after
1 hour and re-starts
after another 5 hours.
Delay ON and
Example :
OFF Timer
Operation starts after
10 hours, and then
stops after another 8
hours.
• Then press the Timer Setting Button
2
or
3
to the
desired number of hours.
(Number of hours which can be set : 1 ~ 12)
• Press the Timer Set/Cancel Button
4
Heat Pump Model
←
1 hour
→
Sleep shift
operation starts.
Approx. 3°C
decrease.
• Cooling or Soft Dry
Operation for sleep shift
operation will start to
avoid overcooling.
• Heating operation for
sleep shift operation will
start to avoid overheating.
Sleep
Operation
button is
pressed.
0~1 hour
Approx. 2°C
decrease.
Approx.
1°C
increase.
Approx. 1°C
increase.
Temperature
S
e
t
t
i
n
g
T
e
m
p
e
r
a
t
u
r
e
Time
←
1 hour
→
after approx. 5 hours of sleep shift
operation, it will stop automatically.
Time
Approx. 1°C
increase.
Temperature
Sleep
Operation
button is
pressed.
Sleep shift
operation
starts.
0~1 hour
←
1 hour
→
after approx. 5 hours of sleep shift
operation, it will stop automatically.
Approx.
1°C
increase.
• Cooling or Soft Dry
Operation for sleep shift
operation will start to
avoid overcooling.
S
e
t
t
i
n
g
T
e
m
p
e
r
a
t
u
r
e
When the room temperature
become a level ideal for
sleep, the operation 10
minutes on and 20 minutes
off will be repeated.
23
CS-A12ATP5 CU-A12ATP5 / CS-A18ATP5 CU-A18ATPT5 / CS-A24ATP5 CU-A24ATPT5
Summary of Contents for CS-A12ATP5
Page 11: ...3 Dimensions 11 CS A12ATP5 CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ...
Page 12: ...12 CS A12ATP5 CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ...
Page 14: ...5 Block Diagram 14 CS A12ATP5 CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ...
Page 15: ...15 CS A12ATP5 CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ...
Page 16: ...6 Wiring Diagram 16 CS A12ATP5 CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ...
Page 17: ...17 CS A12ATP5 CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ...
Page 39: ...12 Technical Data 39 CS A12ATP5 CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ...
Page 42: ...13 Exploded View 42 CS A12ATP5 CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ...
Page 44: ...15 Exploded View 44 CS A12ATP5 CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ...
Page 54: ...18 1 REMOTE CONTROL 54 CS A12ATP5 CU A12ATP5 CS A18ATP5 CU A18ATPT5 CS A24ATP5 CU A24ATPT5 ...