3. Do the following connections by referring the illustration.
• Connect iris cameras to the iris camera connectors.
• Connect an electric lock to the GATE 1 connector./ Connect an access control panel to the GATE 2 connector.
• Connect a LAN cable to the LAN connector.
Wrap the supplied ferrite cores around the cables connected to the GATE 1 connector and LAN connector.
16
2. Pass the DC power cable through the upper cable holes, and then mount the control unit over the wall.
Make two holes to attach the supplied bushing
or a flexible metal conduit described in the figure.
Use a metal conduit.
Use a metal conduit.
Cable holes
Flexible metal conduit
Trade size
mm {In.}
Internal
diameter
mm {In.}
Total area
100 %
mm
2
{In.
2
}
2 wires
31 %
mm
2
{In.
2
}
Over 2
wires
40 %
mm
2
{In.
2
}
1 wire
53 %
mm
2
{In.
2
}
19 {3/4}
25.4 {1}
32 {1-1/4}
21 {0.82}
26 {1.02}
32 {1.28}
13.5 {0.53}
21 {0.82}
32 {1.28}
4.2 {0.17}
6.4 {0.25}
10 {0.40}
5.4 {0.21}
8.3 {0.33}
13 {0.51}
7.2 {0.28}
11 {0.43}
17 {0.68}
Note:
Use metal conduits when designated by the electrical regulation.