Operating Instructions
73
Setting
Description
Enable Pre-
trigger Image
Buffer
•
Check the box to enable the setting. The camera buffers or
transfers the image right before the pyroelectric infrared
sensor detects temperature differences.
•
Set an interval, number of images to buffer and total
number. The buffered images may not match the total
number due to memory capacity, image resolution, image
quality or what object you view.
Enable Post-
trigger Image
Buffer
•
Check the box to enable the setting. The camera buffers or
transfers the image right after the pyroelectric infrared
sensor detects temperature differences.
•
Set an interval, number of images to buffer and total
number. The buffered images may not match the total
number due to memory capacity, image resolution, image
quality or what object you view.
Sensor
deactivation
time
•
Set the length of time during which the sensor cannot be
triggered after saving images temporarily or transmitting
them. This function is recommended to prevent sending
too many E-mails to a cell phone.
Note
The internal memory cannot buffer images during Sensor
deactivation time. Because of this, images taken before
detection are not saved in internal memory, and so cannot
be received. Depending on the settings for image buffer/
transfer, even if it is set to, for example, take "1 image per
second, and store 10 images, before detection", because
the images are not stored in internal memory, if the sensor
detects something directly after the end of Sensor
deactivation time, the images may not be saved. Ten
seconds after the end of Sensor deactivation time, images
can be received as specified in the settings.