![Panasonic AWE350 - COLOR CAMERA Operating Instructions Manual Download Page 45](http://html1.mh-extra.com/html/panasonic/awe350-color-camera/awe350-color-camera_operating-instructions-manual_3949648045.webp)
-45-
5. Electronic Shutter Mode Setting
[Shutter Mode: Step, ELC, S/Scan]
Step:
Electronic shutter operates at the speed
selected by the Electronic Shutter Step/Synchro
Scan Setting (
6
-
6
).
ELC:
Electronic shutter is controlled to automatically
adjust the luminance.
S/Scan (Synchro Scan):
Electronic shutter operates
at the speed selected in Electronic Shutter
Step/Synchro Scan Setting (
6
-
6
).
6. Electronic Shutter Step/Synchro Scan Setting
[Step/Synchro: OFF, 1/100 to 1/10 000 (step),
60.34Hz to 15.75kHz (Synchro Scan)]
This can be set when “Step” or “Synchro Scan” has
been selected as the electronic shutter mode setting
(
6
-
5
).
• When “Step” has been selected as the electronic
shutter mode setting (
6
-
5
):
OFF:
The electronic shutter is set to OFF.
1/100, 1/250, 1/500, 1/1 000, 1/2 000, 1/4 000, 1/10 000:
The electronic shutter operates at the shutter
speed selected.
• When “Synchro Scan” has been selected as the
electronic shutter mode setting (
6
-
5
):
When the screen of a work station, etc. is to be
shot, the noise on the horizontal bars can be
reduced by proceeding with the synchro-scan
adjustment.
❈
Refer to the table below for the light quantity set-
tings to be used in each shutter mode and during
synchro scanning.
If Frame 1 is selected in CCD Read Out Mode
Setting (
;
-
9
), Electronic Shutter Mode Setting
cannot be added.
Note
Shutter Speed
OFF
1/100
1/250
1/500
1/1 000
1/2 000
1/4 000
1/10 000
Synchro-scan
-
100.3 Hz
250.0 Hz
492.2 Hz
984.4 Hz
1.969 kHz
3.938 kHz
7.875 kHz
Required luminance ratio
1
2
4
8
16
32
64
160
• In case of using the RCU (RCB), none of the
shutter speeds – 1/250, 1/2 000, 1/4 000, and
1/10 000 can be selected.
• In case of using the hybrid control panel, only
OFF, 1/100, or ELC can be selected.
• If the lens iris switch is at M (Manual) when
operating the camera alone or when the iris
switch on the RCU (RCB) is at AUTO, ELC
may not function. Set the lens iris switch to A
(Auto).
• Flickering may increase at ELC under fluorescent
lights.
Notes