![background image](http://html1.mh-extra.com/html/panasonic/aw-he145kp/aw-he145kp_operating-instructions-manual_3629874008.webp)
Installation Instructions
Be sure to configure the switches on the connector panel and bottom of the unit before installing it.
Configuring the switches after the unit is installed may prove difficult.
Before installation
IR ID switch settings
The IR ID switches are located on the connector panel of the unit.
12 V
IN
IR ID AUDIO IN
RS-422
SERVICE
3G SDI OUT G/L IN
LAN
LINK ACT
IR ID switch
CAM1
CAM2
CAM3
CAM4
These are used to select the ID of the wireless remote control (optional
accessory). (→ page 56)
The IR ID switch settings “CAM1” to “CAM4” correspond to the
CAMERA buttons <1> to <4> on the wireless remote control.
Service switch settings
The service switches are located on the connector panel of the unit.
Perform switch settings before turning the unit on.
12 V
IN
IR ID AUDIO IN
RS-422
SERVICE
3G SDI OUT G/L IN
LAN
LINK ACT
SW1
ON
OFF
SW2 SW3 SW4
Service switch
Function
Factory settings
SW1
Switches for initialization
(Refer to the explanations in “Initialization 1”
and “Initialization 2”)
OFF
SW2
Always leave at OFF (used for factory
adjustments)
OFF
SW3
OFF
SW4
OFF
Initialization 1
• Reset the user authentication settings and host authentication settings
for network connection.
(This will delete all the registered user information (IDs/passwords)
and host information (IP addresses).)
• With the IR ID switches and service switches set as shown below, turn
on the power of the unit.
SW1
ON
OFF
SW2 SW3 SW4
<NOTE>
• When initialization is complete, the status display lamp on the front
of the unit blinks green. Set the service switches back to their original
positions (SW1 to SW4 all OFF), then restart the unit.
Initialization 2
•
The unit is reset to the state it was in at the time of purchase. (All
camera menu setting values and network setting values are reset.)
• With the IR ID switches and service switches set as shown below, turn
on the power of the unit.
SW1
ON
OFF
SW2 SW3 SW4
<NOTE>
• When initialization is complete, the status display lamp on the front
of the unit blinks green. Set the service switches back to their original
positions (SW1 to SW4 all OFF), then restart the unit.