4
Sharpness (DTL) Set Display
@
Detail Select Setting [DTL Select: Normal, Super DTL]
If contour correction is not sufficient at the Normal
position when Detail Level setting is set to Low or High,
select the Super DTL position.
A
Detail Level Setting [Level: OFF, Low, High]
Detail level can be adjusted when Detail Select setting is
at Normal. Super DTL level can be adjusted when it is at
Super DTL.
In case of using the RCU (RCB), the above can be
adjusted with the contour correction switch (DTL).
B
Noise Suppress Level Setting
[Noise Suppress: OFF, Low, High]
Screen noise can be reduced when Detail Level setting is
at High or Low.
C
Clean DNR Setting [Clean DNR: OFF, Low, High]
This enables the clean DNR effect to be selected.
D
Flesh Noise Suppress Level Setting
[Flesh Noise Sup.: OFF, Low, High]
Flesh noise is suppressed in two steps when the Detail
Level Setting is at High or Low.
- 36 (E) -
ENGLISH
RCU (RCB)
DTL switch
Note
Neither Normal nor Super DTL is valid for contour
correction if Detail Level setting is in the OFF position.