background image

AECTB11E   202110

Panasonic Corporation 2021

FEATURES

Complies with IEC62368-1 secondary circuit 

insulation distance standards (basic insulation)

Subminiature size realized as door interlock switches

Excellent operating position accuracy

Protection grade: IP40

Subminiature Size Door Inter-lock Switches

AV3 (FS) Switches Contact gap 1 mm Type

For detection: Non Seal Type Switches

TYPICAL APPLICATIONS

Office equiment (printers, copiers, etc.)

(Unit: mm)

19.8

6.4

11.1

ORDERING INFORMATION (PART NO.)

AV 3

5

3

G

Operating Force (OF) 

by pin plunger (Max.)

5: 1.47 N

G: Contact gap More than 1 mm type

Terminals
2: Solder terminal without guard

4: Self-standing P/C board terminal

8: .110 Quick-connect terminal

Actuators
0: Pin plunger
1: Short hinge lever
2: Hinge lever
3: Long hinge lever
4: Simulated roller lever
5: Roller lever

Safety standard

3: UL/C-UL, TÜV, ENEC/VDE

Note) When ordering, please add "-A" at the end of the part number.

TYPES

Actuator

Operating Force 

(OF) Max.

Part number

Solder terminal

Self-standing P/C board terminal

.110 Quick- connect terminal

Pin plunger

1.47 N

AV3205G3

AV3405G3

AV3805G3

Short hinge lever

0.59 N

AV3215G3

AV3415G3

AV3815G3

Hinge lever

0.54 N

AV3225G3

AV3425G3

AV3825G3

Long hinge lever

0.44 N

AV3235G3

AV3435G3

AV3835G3

Simulated roller lever

0.54 N

AV3245G3

AV3445G3

AV3845G3

Roller lever

0.59 N

AV3255G3

AV3455G3

AV3855G3

industrial.panasonic.com/ac/e/

2021.10

ー 1 ー

Summary of Contents for AV3205G3

Page 1: ...s 2 Solder terminal without guard 4 Self standing P C board terminal 8 110 Quick connect terminal Actuators 0 Pin plunger 1 Short hinge lever 2 Hinge lever 3 Long hinge lever 4 Simulated roller lever 5 Roller lever Safety standard 3 UL C UL TÜV ENEC VDE Note When ordering please add A at the end of the part number TYPES Actuator Operating Force OF Max Part number Solder terminal Self standing P C ...

Page 2: ...resistance malfunction shock resistance 294 m s2 Pin plunger type 147 m s2 Lever type Contact opening Max 1 msec Allowable operation speed No load 0 1 to 1 000 mm s Max switching frequency No load 300 cpm Ambient temperature 25 to 85 C no freezing and condensing Unit weight Approx 2 g Contact specifications Contact material AgNi alloy Protection grade IP40 Note Test conditions are in accordance wi...

Page 3: ...Electrical life The service life when the rated load is connected to the contact and switching operations are performed The life test is performed at a switching frequency of 20 times minute and operating speed of 100 mm second at the regular cam Contact form This refers to the components determining the type of application which make up the electrical input output circuits in the contact SPDT SPS...

Page 4: ...equired to move from an operating position to a total travel position Movement Pretravel PT mm degree Max Distance or agree of the actuator movement from free position to operating position Overtravel OT mm degree Min The distance or degree which the actuator is permitted to travel after actuation without any damage to the switching mechanism Movement Differential MD mm degree Max The distance or ...

Page 5: ...in contact failures or contact fusion 2 An extremely high activation speed may cause damage to contacts or contact response failure Driving Mechanism Use of a driving mechanism which will cause physical impact to the actuator should be avoided Example Bad Good TECHNICAL NOTES ON ELECTRICAL CHARACTERISTICS 1 The snap action switch is designed for AC operations While it has small contact gaps and no...

Page 6: ...h AC and DC Impedance of r is nearly equal to impedance of R C 0 1 μF R diode Contact for snap action switch 1 For DC circuits only ZNR Varistor Contact for snap action switch Induction load Can be used for both AC and DC 2 Do not connect the contacts on individual switches to different type or different poles of the power supply Examples of power supply connections connection to different poles P...

Page 7: ...ting hole 2 Depressed position The plunger lever should be pressed down to 70 or more of OT Over Travel Therefore the depressed position should be calculated based on the minimum value of OP Operating Position and the 70 and 100 of the OT value OP Min 70 of OT 8 0 0 84 7 16 mm OP Min 100 of OT 8 0 1 2 6 80 mm The plunger lever should be pressed down to the position of 6 80 to 7 16 mm from the moun...

Page 8: ...nsation can cause adverse conditions such as deterioration of insulation coil cutoff and rust Condensation or other moisture may freeze on the switch when the temperatures is lower than 0 C 32 F This causes problems such as sticking of movable parts or operational time lags The plastic becomes brittle if the switch is exposed to a low temperature low humidity environment for long periods of time S...

Page 9: ...r is required Hinge lever Large Medium Small Possible Little force required for operation Appropriate for use with low speed cams and dogs has large stroke Lever available in various shapes to fit operating unit Simulated roller lever Large Medium Small Possible Tip of hinge lever is bent into a semi circle enabling use as a simple roller type Leaf lever Large Large Small Excellent Play in lever i...

Page 10: ...Electromechanical Control Business Division industral panasonic com ac e Specifications are subject to change without notice 1006 Oaza Kadoma Kadoma shi Osaka 571 8506 Japan Panasonic Corporation 2021 AECTB11E 202110 ...

Reviews: