background image

 
Live Switcher                                                                                                      IP Interface Specifications   

©

 Panasonic Corporation 2013 All Rights Reserved.

 

- 1 - 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 

Document No. 

Version 1.00 

December 11, 2013 

 

 

 

 

 

 

 

 

 

 

AVC Networks Company   

Panasonic Corporation 

 

Live Switcher   

AV-HS410 

IP Interface Specifications 

(HS410_IF) 

 

Summary of Contents for AV-HS410

Page 1: ...Interface Specifications Panasonic Corporation 2013 All Rights Reserved 1 Document No Version 1 00 December 11 2013 AVC Networks Company Panasonic Corporation Live Switcher AV HS410 IP Interface Specifications HS410_IF ...

Page 2: ...Live Switcher IP Interface Specifications Panasonic Corporation 2013 All Rights Reserved 2 Change History Date Description Version 13 12 11 Issued the first edition 1 00 ...

Page 3: ...ion control command 17 3 7 2 Picture in picture auto transition control command 18 3 7 3 KEY auto transition control command 19 3 8 Cut transition control 20 3 8 1 Background cut transition control command 20 3 8 2 Picture in picture cut transition control command 21 3 8 3 Key cut transition control command 22 3 9 Auto transition time query 23 3 10 Auto transition time control 23 3 11 Query of the...

Page 4: ...e by menu Factory setting 255 255 255 0 Port No 60040 fixed connection to up to 4 ports concurrently is possible for the purposes of external control Minimum command interval 1 frame or more For details on the configuration of the communication commands refer to chapter 2 for details on the commands of the functions refer to chapter 3 2 2 Command configuration One packet starts with STX 0x02 and e...

Page 5: ...s crosspoint control Abnormal Abnormal message Fig 2 3 1 4 Sequence of control commands 4 External unit 0x02 SBUS 00 00 0x03 AV HS410 Process for establishing connection Process for terminating connection 0x02 ABUS 00 00 0x03 External unit 0x02 SBUS 20 00 0x03 AV HS410 Process for establishing connection Process for terminating connection 0x02 EROR 01 0x03 External unit 0x02 SBUS 0 00 0x03 AV HS41...

Page 6: ...blishing connection 0x02 ABST 00 00 0 0x03 AV HS410 0x02 QBST 00 0x03 Process for terminating connection XPT1 is set for bus A and tally is in Off status 2 3 2 Query commands Example Bus status query XPT When XPT1 is set for bus A and a query is made when the tally is in the Off status Fig 2 3 2 Sequence of query commands ...

Page 7: ...rmat Format STX Command name Parameter 1 Parameter 2 Parameter 3 ETX Format description STX Start Of Text 0x02 Command name Refer to the table of commands below each command consists of 4 letters Parameter 1 Refer to the parameter values of the commands Parameter 2 Refer to the parameter values of the commands Parameter 3 Refer to the parameter values of the commands ETX End Of Text 0x03 ...

Page 8: ...ition control 60040 3 9 3 10 QTIM Auto transition time query 60040 ATIM Auto transition time response return 60040 STIM Auto transition time control 60040 3 11 3 12 QBTI Bus transition settings status query 60040 ABTI Bus transition settings status response return 60040 SBTI Bus transition settings 60040 3 13 3 14 QPAT Transition pattern query 60040 APAT Transition pattern response return 60040 SP...

Page 9: ...age that has a response is sent the switcher returns an error response Command name Category Command Parameter value Setting Remarks Error response Response EROR Parameter 1 Parameter 1 01 02 Abnormality details Parameter out of range Abnormal message when unrecognized This response is used when an error occurs for control that involves a response ...

Page 10: ...mode PGM PGM column regardless of mode PVW PVW column regardless of mode KEY Fill KEY Source DSK Fill DSK Source PinP1 PinP2 AUX1 AUX2 AUX3 AUX4 Materials XPT1 to XPT24 Input1 to Input13 Color bars Color background 1 Black Still1V Still2V Clip1V Clip2V PGM PVW KeyOut CLN Multi View M PVW Still1K Still2K Clip1K Clip2K Color background 2 The QBST command or QBSC command is used when the current bus ...

Page 11: ...l1K Still2K Clip1K Clip2K Color background 2 Caution 1 Even for image materials for which crosspoint is not set unassigned status if an input number and material name are selected by using Parameter 2 of the SBUS command crosspoint selection is possible In this case the crosspoint button on the operating panel will be unlit 2 If you select a crosspoint number for image materials for which crosspoi...

Page 12: ...nput1 to Camera 2 Input2 Example input materials Camera 1 Camera 2 Camera 3 Captions Crosspoint status Current status Status after control Output image Fig 3 4 1 Sequence of the PGM bus switching command Direct switching of the PGM bus Effect similar to a CUT transition Process for establishing connection 0x02 ABUS 02 01 0x03 0x02 SBUS 02 01 0x03 AV HS410 Process for terminating connection Externa...

Page 13: ...Y Fill KEY Source DSK Fill DSK Source PinP1 PinP2 AUX1 AUX2 AUX3 AUX4 This command which is the crosspoint query command is returned by ABST To ascertain the status of materials use the QBSC command instead Response ABST Parameter 1 Parameter 2 Parameter 3 Parameter 1 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Parameter 2 00 to 23 99 Parameter 3 0 1 Select the bus command Bus A top side regar...

Page 14: ... AUX2 AUX3 AUX4 This command which is the materials query command is returned by ABSC To ascertain the status of crosspoints use the QBST command instead Response ABSC Parameter 1 Parameter 2 Parameter 3 Parameter 1 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Parameter 2 50 to 62 70 71 72 73 74 75 76 77 78 79 80 81 82 90 91 92 93 Select the bus command Bus A top side regardless of mode Bus B b...

Page 15: ...Live Switcher IP Interface Specifications Panasonic Corporation 2013 All Rights Reserved 15 94 95 96 Parameter 3 0 1 Clip1K Clip2K Color background 2 Tally information Tally Off Tally On ...

Page 16: ...UT Parameter 1 Parameter 2 Parameter 3 Parameter 1 00 01 04 05 06 07 Parameter 2 0 1 Parameter 3 0 1 2 Materials BKGD KEY PinP1 PinP2 FTB DSK Effects when BKGD is selected for Parameter 1 MIX WIPE Operation setting Trigger On issued when the regular AUTO button is pressed On Take transition from Off On Except when BKGD is selected Off Take transition from On Off Except when BKGD is selected This c...

Page 17: ...y 0 5 seconds Example input materials Camera 1 Camera 2 Camera 3 Captions Crosspoint status Current status Status after control Fig 3 7 1 Sequence of the BKGD mix auto transition command Auto transition Images are switched by using the set time of 015 frames approximately 0 5 seconds Output image 0x02 ABUS 03 01 0x03 0x02 SBUS 03 01 0x03 0x02 ATIM 00 015 0x03 0x02 STIM 00 015 0x03 Process for term...

Page 18: ...ge is released in 0 frames cut effect Example input materials Camera 1 Camera 2 Camera 3 Captions Crosspoint status Current status Status after control Fig 3 7 2 Sequence of the PinP off auto transition command PinP1 auto transition Execution of an Off control release at the set time of 0 frames Process for terminating connection AV HS410 S410 External control unit 0x02 ATIM 04 000 0x03 0x02 STIM ...

Page 19: ...key on top of a background image is released in 0 frames cut effect Example input materials Camera 1 Camera 2 Camera 3 Captions Crosspoint status Current status Status after control Fig 3 7 3 Sequence of the key off auto transition command Output image AV HS410 External control unit Process for terminating connection Process for establishing connection 0x02 STIM 01 000 0x03 0x02 ATIM 01 000 0x03 0...

Page 20: ...Y PinP1 PinP2 FTB DSK 3 8 1 Background cut transition control command Example Cut transition control of background images When XPT3 camera image 3 is selected for the PVW bus and a cut transition is executed Example input materials Camera 1 Camera 2 Camera 3 Captions Crosspoint status Current status Status after control Fig 3 8 1 Sequence of the BKGD cut transition command 3 2 2 CUT Output image A...

Page 21: ...nto a background image Note For details about releasing PinP images refer to the section describing auto transition control Example input materials Camera 1 Camera 2 Camera 3 Captions Crosspoint status Current status Status after control Fig 3 8 2 Sequence of the PinP CUT in command Output image PinP CUT in AV HS410 External control unit 0x02 ABUS 10 02 0x03 0x02 SBUS 10 02 0x03 0x02 SCUT 04 0x03 ...

Page 22: ...ing on a background image Example input materials Camera 1 Camera 2 Camera 3 Captions Crosspoint status Current status Status after control Fig 3 8 3 Sequence of the key CUT in insertion command Output image Key CUT in Characters are displayed by using the color set for the fill color External control unit AV HS410 Process for establishing connection 0x02 SBUS 04 03 0x03 0x02 ABUS 04 03 0x03 0x02 ...

Page 23: ...K Times in frame units 000 to 999 frames This command is returned in response to the QTIM command 3 10 Auto transition time control This command controls the time for each auto transition Command name Category Command Parameter value Setting Remarks Auto transition time control response Control STIM Parameter 1 Parameter 2 Parameter 1 00 01 04 05 06 07 Parameter 2 000 to 999 Transition target sett...

Page 24: ...Enable Disable Times in frame units 000 to 999 frames This command is returned in response to the QBTI command 3 12 Bus transition settings This command sets the bus transitions mix effects for the AUX1 PinP1 and PinP2 buses Command name Category Command Parameter value Setting Remarks Bus transition settings Control SBTI Parameter 1 Parameter 2 Parameter 3 Parameter 1 01 02 03 Parameter 2 01 02 P...

Page 25: ...ansition pattern control This command controls the transition patterns Command name Category Command Parameter value Setting Remarks Transition pattern control response Control SPAT Parameter 1 Parameter 1 01 02 Parameter 2 01 to 09 11 to 19 61 to 69 Type BKGD KEY Pattern WIPE01 to 09 WIPE11 to 19 WIPE61 to 69 Response APAT Parameter 1 Parameter 2 Parameter 1 01 02 Parameter 2 01 to 09 11 to 19 61...

Page 26: ...eter 6 Parameter 1 1 2 Parameter 2 10000 to 10000 Parameter 3 10000 to 10000 Parameter 4 00000 to 10000 Parameter 5 0 1 2 3 4 Parameter 6 0 1 2 3 4 Target setting PinP1 PinP2 Center X position 100 00 to 100 00 Note Fixed at 6 digits 00000 00000 Center Y position 100 00 to 100 00 Note Fixed at 6 digits 00000 00000 Size 000 00 to 100 00 Note Fixed at 5 digits e g 10 00 becomes 01000 Border width Non...

Page 27: ...000 Size 000 00 to 100 00 Note Fixed at 5 digits e g 10 00 becomes 01000 Border width None Small Medium Large No change Border color White Gray 1 Gray 2 Black No change Response APNP Parameter 1 Parameter 2 Parameter 3 Parameter 4 Parameter 5 Parameter 6 Parameter 1 1 2 Parameter 2 10000 to 10000 Parameter 3 10000 to 10000 Parameter 4 00000 to 10000 Parameter 5 0 1 2 3 4 Parameter 6 0 1 2 3 4 Targ...

Page 28: ... OFF ON Off control will return the material to BKGD Response ASBS Parameter 1 Parameter 1 0 1 Status OFF ON This command is returned in response to the SSBS command Note When the side by side setting is on the picture in picture settings below will be applied Also when the side by side setting is off the picture in picture settings will return to the values that they were set to previously 1 Posi...

Page 29: ...e and XPT3 Camera 3 right side on 2 screens Example input materials Camera 1 Camera 2 Camera 3 Captions Crosspoint status Current status Status after control Fig 3 18 1 Sequence of the side by side execution command Output image External control unit AV HS410 0x02 SBUS 10 01 0x03 0x02 ABUS 10 01 0x03 Process for establishing connection 0x02 SBUS 11 02 0x03 0x02 ABUS 11 02 0x03 0x02 SSBS 1 0x03 0x0...

Page 30: ...n the side by side display is released and a background image is displayed Example input materials Camera 1 Camera 2 Camera 3 Captions Crosspoint status Current status Status after control Fig 3 18 2 Sequence of the side by side release command Output image External control unit AV HS410 Process for establishing connection Process for terminating connection 0x02 SSBS 0 0x03 0x02 ASBS 0 0x03 ...

Reviews: