background image

3

Contents

For Your Safety  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Precautions for Use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Controls and their Functions

_

Front panel  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

_

Rear panel  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

How To Connect  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Appearance and Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Outline

This unit is able to separate multiple data (camera control data and swivel stand control
data) transmitted from the camera controller (AK-HRP900P), and to output the control
information to the multi-purpose camera (AK-HC900P) and the swivel stand (AW-
PH300A, etc.).

The distance between this unit and the camera is 33 ft (10m) max.

Precautions for Use

We recommend that the AC adapter AW-PS505P is used for power supply.

Handle the unit with care.
If dropped or given a strong shock, it may cause a trouble or accident.

Use the unit in a temperature range of 32

o

F to 104

o

F (0

o

C to + 40

o

C).

If used at a temperature below 32

o

F or higher than 104

o

F, it may cause bad influences to

the component parts.

Turn off the power before connecting or disconnecting the cable.
When connecting or disconnecting the cable, be sure to turn off the power switch of the
unit beforehand.

Avoid using the unit outdoors.

Install the unit 3.3 ft (1 m) away from the monitor.

Maintenance
Pull out the power cord plug and clean the unit with dry cloth.  If it is hard to clean,
moisten the cloth with a diluted neutral detergent solution and squeeze it well and lightly
wipe the unit.

Do not use volatile solvents such as benzene or thinner.

When using a chemical mop, carefully read the instructions.

Precautions

Summary of Contents for AKHTF900P - INTERFACE ADAPTOR

Page 1: ...Before attempting to connect operate or adjust this product please read these instructions completely and save this manual for future use Model AK HTF900P Interface Adapter ...

Page 2: ...UCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER TO SERVICING TO QUALIFIED SERVICE PERSONNEL RISK OF ELECTRIC SHOCK DO NOT OPEN The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to c...

Page 3: ...re If dropped or given a strong shock it may cause a trouble or accident Use the unit in a temperature range of 32oF to 104oF 0oC to 40oC If used at a temperature below 32oF or higher than 104oF it may cause bad influences to the component parts Turn off the power before connecting or disconnecting the cable When connecting or disconnecting the cable be sure to turn off the power switch of the uni...

Page 4: ...ch 2 is ON it is lighted green With the power control switch 2 set to OFF it goes out 2 Power control switch POWER ON OFF When this switch is set to ON this unit and the camera connected to it are turned on With the switch set to OFF both of the unit and the camera are tuned off Controls and their Functions ...

Page 5: ...12V IN PAN TILT CONTROL OUT 3 4 5 7 6 _Rear panel 1 7 2 3 4 5 6 8 9 10 11 12 13 14 15 1 7 2 3 4 5 6 8 9 10 11 12 13 14 15 1 7 2 3 4 5 6 8 9 10 11 12 13 14 15 Controls and their Functions Signal NC NC NC NC DC 12V Frame GND TXD H Pin No 8 9 10 11 12 13 14 15 Signal NC NC NC NC DC GND TXD C RXD H RXD C Pin No 1 2 3 4 5 6 7 TXD Data from camera to remote controller RXD Data from remote controller to ...

Page 6: ...er breaker The breaker operates to cut off the power in case of over current 7 DC12V input connector DC 12V IN XLR4 pin Connects the AC adapter We recommend that the AW PS505P option is used 1 2 3 4 Controls and their Functions Pin No 1 2 3 4 ...

Page 7: ...S CHECK Interface adapter AK HTF900P Make the connections with all the units turned off We recommend that the AW PS505P option is used as AC adapter Use a swivel stand AW PH300A AW PH500 AW PH600 and an adapter suited for the swivel stand Remote zoom focus control cable Swivel stand controller AW RP301 Swivel stand AW PH300A Multi purposedigitalcamera AK HC900P Multi cable 17 ft AK HDMLTCA05 Camer...

Page 8: ...Appearance and Dimensions 8 mm POWER OFF ON Interface Adapter CAMERA CN DATA IN BEAKER DC 12V IN PAN TILT CONTROL OUT 8 3 16z 206 5 9 7 8z 250 2 1 8z 42 4 7 16z 10 3 ...

Page 9: ...control 33 ft 10m 32oF to 104oF 0oC to 40oC 8 3 16 W k2 1 8 H k9 7 8 D inch 206 5k52 7k250 mm Approx 4 18 lbs 1 9 kg AV ivory coating Munsell 7 9Y 6 8 0 8 approx color 1is the safety information Power supply DC 12V XLR 4 pin connector Power consumption 25 W with camera connected Weight and dimensions shown are approximate Specifications are subject to change without notice ...

Page 10: ...10 Memo ...

Page 11: ...11 Memo ...

Page 12: ... Los Angeles CA 90068 323 436 3500 Government Marketing Department 52 West Gude Drive Rockville MD 20850 301 738 3840 Broadcast PARTS INFORMATION ORDERING 9 00 a m 5 00 p m EST 800 334 4881 24 Hr Fax 800 334 4880 Emergency after hour parts orders 800 334 4881 TECHNICAL SUPPORT Emergency 24 Hour Service 800 222 0741 Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario L4W 2T3 905 624 5010 Pan...

Reviews: