background image

16

Setting of SD-HD V item: ADVANCE (75H)

1122 1123 1124 1125

1

2

3

4

5

6

7

1122 1123 1124 1125

1

2

3

4

5

6

7

624

625

1

2

3

4

624

625

1

2

3

4

GEN LOCK

Black burst signal

CCU_VBS/SDI (SD)_OUT

75H (HD) LINE

CAM_HD_SDI_OUT

CCU_HD_SDI_OUT

z

z

4 .43 BB signal

  (626/50/I)

z

z

VBS/SDI (SD) signal

  (626/50/I)

z

z

HD_SDI signal

  (1125/50/I)

z

z

HD_SDI signal

  (1125/50/I)

Setting of SD-HD V item: 0H_SD_DLAY (1FRAM–75H DLY)

1122 1123 1124 1125

1

2

3

4

5

6

7

1122 1123 1124 1125

1

2

3

4

5

6

7

624

625

1

2

3

4

624

625

1

2

3

4

GEN LOCK

Black burst signal

CCU_VBS/SDI (SD)_OUT

1FRAM–75H (HD) LINE

CAM_HD_SDI_OUT

CCU_HD_SDI_OUT

z

z

4 .43 BB signal

  (626/50/I)

z

z

VBS/SDI (SD) signal

  (626/50/I)

z

z

HD_SDI signal

  (1125/50/I)

z

z

HD_SDI signal

  (1125/50/I)

Setting menu items 

(Continued)

Summary of Contents for AKHCU200

Page 1: ...ng Instructions are configured Basics The Basics describes the procedure for connection with the required equipment and for installation Before installing this unit be sure to take the time to read through Basics to ensure that the unit will be installed correctly Operations and Settings this manual This Operations and Settings describes how to operate the unit and how to establish its settings ...

Page 2: ...ademarks or trademarks of their respective companies Copyrights It is prohibited to transfer copy disassemble decompile and reverse engineer the software included with the unit as well as export it in violation of the export laws Illustrations and screen images in this manual z z Illustrations of the unit and screens may appear different from the actual unit and screens z z The screenshots are use...

Page 3: ... display switches to the status screen IRIS or status display z z Hold down the CHARA button of the ROP The warning displays are cleared Warnings are automatically displayed when trouble is detected z z Self recovery The warning displays are cleared z z Press the SELECT dial on the unit When the transition source screen is displayed The display switches to the transition source screen When the tra...

Page 4: ... at the top left of the screen the IRIS level is displayed at the bottom of the screen and the IRIS f value is displayed at the bottom right of the screen Set each item to be displayed on the PM VIEW SETTING screen that can be accessed by selecting MAINTENANCE on the menu However this screen will not appear if the menu s IRIS LEVEL setting is OFF C1 F4 8 C 0 Camera number IRIS f value IRIS level T...

Page 5: ...put signals HD SKIN DETAIL OFF ON The status of the skin tone detail function for the HD signals is displayed here z z This function minimizes or emphasizes the detail components applied to the skin tone MATRIX OFF ON The status of the matrix function is displayed here z z This function compensates the saturation and hue z z Status displays page 2 of 4 From the status displays page 1 of 4 screen p...

Page 6: ... output from 1 and 2 of the HD SD SDI OUT connectors is displayed here SDI OUTPUT3 4 HD SD The format of the signals to be output from 3 PM and 4 PM of the HD SD SDI OUT connectors is displayed here SDI OUTPUT3 4 NORMAL PM NORMAL PM The setting information for output from 3 PM and 4 PM of the HD SD SDI OUT connectors is displayed here COMPOSITE NORMAL PM NORMAL PM The signal to be output from OUT ...

Page 7: ... using the SCENE command z z Operation displays AUTO If the AWB function ABB function or AUTO SETUP function has been activated when a menu is not displayed on the picture monitor information on the operation performed appears at the bottom of the screen When the AUTO SETUP operations are displayed they will remain displayed until the operations are completed The display is cleared 4 seconds after...

Page 8: ...NGE ABB Bch OUT RANGE ABB Rch OUT RANGE B SHD Gch OUT RANGE B SHD Bch OUT RANGE B SHD Rch OUT RANGE FLARE Gch OUT RANGE FLARE Bch OUT RANGE FLARE Rch OUT RANGE AWB Gch OUT RANGE AWB Bch OUT RANGE AWB Rch OUT RANGE NOT RUNNING ILLEGAL MODE CINEGAMMA NOT RUNNING ILLEGAL MODE D EXT NOT RUNNING ILLEGAL MODE SCANREVERSE NOT RUNNING ILLEGAL MODE BAR NOT RUNNING ILLEGAL MODE TESTSAW z z Contrast automati...

Page 9: ...RATION or MAINTENANCE on the TOP MENU screen and then press the SELECT dial to display the menu screen one level below the selected item z z When the SELECT dial is turned clockwise the cursor moves down conversely when it is turned counterclockwise the cursor moves up TOP MENU OPERATION MAINTENANCE 2 Turn the SELECT dial to move the cursor to the menu item you want to set and then press the SELEC...

Page 10: ... items with multiple setting items on one line and text input menu items 1 Turn the SELECT dial to move the cursor to the menu item you want to set and then press the SELECT dial The cursor becomes and you can use the SELECT dial to move the cursor to a setting item in the selected menu item BAR ID BAR ID SWITCH OFF BRIGHTNESS 100 ID1 POSITION V 00 H 00 ID1 ID2 POSITION V 01 H 00 2 Turn the SELECT...

Page 11: ...TE NORMAL PM PM indicates the factory default setting Item Setting value Remarks CCU MODE 59 94 Hz 1080 59 94i 1080 50i Set the format of the signal to be output from the unit 50 Hz 1080 59 94i 1080 50i SDI RETURN1 HD SD Set the format of the return signal to be input to HD SD SDI 1 of the RETURN IN connectors SDI RETURN2 HD SD Set the format of the return signal to be input to HD SD SDI 2 of the ...

Page 12: ...color bar placed in an area with a 4 3 aspect ratio Displayed 40 gray outside the area BARS 5 Color bar based on the SMPTE standard that is placed in an area with a 4 3 aspect ratio Displayed 40 gray outside the area BARS 6 Color bar based on the EIAJ standard that is placed in an area with a 4 3 aspect ratio Displayed 40 gray outside the area Item Setting value Remarks BAR LPF OFF 3TAP 5TAP 7TAP ...

Page 13: ... V 0H ADVANCE 0H_SD_DLAY Set the vertical phase of the HDTV output in relation to the SDTV output 0H Sets the vertical phase to the same phase ADVANCE When the field frequency is 59 94 Hz the phase advance is 90H When the field frequency is 50 Hz the phase advance is 75H 0H_SD_DLAY The SDTV signals are delayed and set in phase with the HDTV signals z z When the setting of this item is set to 0H or...

Page 14: ... 59 94 I z z VBS SDI SD signal 525 59 94 I z z HD_SDI signal 1125 59 94 I z z HD_SDI signal 1125 59 94 I Setting of SD HD V item ADVANCE 90H 2 3 4 5 6 1122 1123 1124 1125 1 2 3 4 5 6 7 1122 1123 1124 1125 1 2 3 4 5 6 7 2 3 4 5 6 GEN LOCK Black burst signal CCU_VBS SDI SD _OUT 90H HD LINE CAM_HD_SDI_OUT CCU_HD_SDI_OUT z z 3 58 BB signal 525 59 94 I z z VBS SDI SD signal 525 59 94 I z z HD_SDI signa...

Page 15: ... VBS SDI SD signal 525 59 94 I z z HD_SDI signal 1125 59 94 I z z HD_SDI signal 1125 59 94 I 1080i 50 Hz format Setting of SD HD V item 0H 624 625 1 2 3 4 1122 1123 1124 1125 1 2 3 4 5 6 7 1122 1123 1124 1125 1 2 3 4 5 6 7 624 625 1 2 3 4 GEN LOCK Black burst signal CCU_VBS SDI SD _OUT CCU_HD_SDI_OUT 75H HD LINE CAM_HD_SDI_OUT z z 4 43 BB signal 626 50 I z z VBS SDI SD signal 626 50 I z z HD_SDI s...

Page 16: ...SDI SD signal 626 50 I z z HD_SDI signal 1125 50 I z z HD_SDI signal 1125 50 I Setting of SD HD V item 0H_SD_DLAY 1FRAM 75H DLY 1122 1123 1124 1125 1 2 3 4 5 6 7 1122 1123 1124 1125 1 2 3 4 5 6 7 624 625 1 2 3 4 624 625 1 2 3 4 GEN LOCK Black burst signal CCU_VBS SDI SD _OUT 1FRAM 75H HD LINE CAM_HD_SDI_OUT CCU_HD_SDI_OUT z z 4 43 BB signal 626 50 I z z VBS SDI SD signal 626 50 I z z HD_SDI signal...

Page 17: ..._HD_SDI_OUT z z Tri level sync signal 1125 59 94 I z z VBS SDI SD signal 525 59 94 I z z HD_SDI signal 1125 59 94 I z z HD_SDI signal Setting of SD HD V item ADVANCE 90H 1122 1123 1124 1125 1 2 3 4 5 6 7 1122 1123 1124 1125 1 2 3 4 5 6 7 1122 1123 1124 1125 1 2 3 4 5 6 7 2 3 4 5 6 GEN LOCK Tri level sync signal CCU_VBS SDI SD _OUT CAM_HD_SDI_OUT 90H HD LINE CCU_HD_SDI_OUT z z VBS SDI SD signal 525...

Page 18: ...nal 1125 59 94 I z z VBS SDI SD signal 525 59 94 I z z HD_SDI signal 1125 59 94 I z z HD_SDI signal 1FRAM 90H HD LINE 1080i 50 Hz format Setting of SD HD V item 0H 1122 1123 1124 1125 1 2 3 4 5 6 7 1122 1123 1124 1125 1 2 3 4 5 6 7 1122 1123 1124 1125 1 2 3 4 5 6 7 624 625 1 2 3 4 GEN LOCK Tri level sync signal CCU_VBS SDI SD _OUT CCU_HD_SDI_OUT 75H HD LINE CAM_HD_SDI_OUT z z Tri level sync signal...

Page 19: ...signal 626 50 I z z HD_SDI signal 1125 50 I z z HD_SDI signal 1125 50 I z z Tri level sync signal 1125 50 I Setting of SD HD V item 0H_SD_DLAY 1FRAM 75H DLY 1122 1123 1124 1125 1 2 3 4 5 6 7 1122 1123 1124 1125 1 2 3 4 5 6 7 1122 1123 1124 1125 1 2 3 4 5 6 7 624 625 1 2 3 4 GEN LOCK Tri level sync signal CCU_VBS SDI SD _OUT CAM_HD_SDI_OUT CCU_HD_SDI_OUT z z Tri level sync signal 1125 50 I z z VBS ...

Page 20: ...ng of BAR ID1 The ID that is set here is displayed on the color bar Up to 16 characters can be set Characters which can be used z z Alphanumeric characters z z Spaces z z _ z z When has been input in the character string this part is replaced by the camera number 1 to 19 and displayed Item Setting value Remarks ID2 POSITION V vertical 00 01 05 H horizontal 00 15 Set the display start position of B...

Page 21: ...the unit CM Carbon microphone DM Dynamic microphone CCU INCOM MIC 40 0dB 0dB 12 0dB Use this to set the level of the unit s intercom microphones for regular use 0 5dB increments CCU SIDE TONE 40 0dB 6dB 0 0dB Use this to set the side tone level of the unit s intercom for regular use 0 5dB increments MAINTENANCE Menu This is the selection screen for the MAINTENANCE menu Moving the cursor to the MAI...

Page 22: ... up in accordance with the VF POWER state that was set with the ROP last time z z ANALOG GAIN Screen This menu is used to set the analog signal levels Moving the cursor to the ANALOG GAIN menu title and then pressing the SELECT dial redisplays the MAINTENANCE menu one level up ANALOG GAIN COMPOSITE 50 indicates the factory default setting Item Setting value Remarks COMPOSITE 50 50 Factory setting ...

Page 23: ...5 255 255 240 255 255 255 248 255 255 255 252 255 255 255 254 255 255 255 255 Set the subnet mask DEFAULT GATEWAY 192 168 0 1 Set the default gateway PORT 1 80 65535 Set the port number MAC ADDRESS Displays the MAC address z z VERSION Screen This menu is used to display the version information for the application software and FPGA Moving the cursor to the VERSION menu title and then pressing the S...

Page 24: ...tems to display on the picture monitor Moving the cursor to the PM OPERATION STATUS menu title and then pressing the SELECT dial redisplays the MAINTENANCE menu one level up PM OPERATION STATUS STATUS DISPLAY TIME 4 MASTER GAIN ON SHUTTER ON LENS EXTENDER ON FILTER ON SCENE FILE ON REF LOAD ON AUTO OPERATION STATUS ON indicates the factory default setting Item Setting value Remarks STATUS DISPLAY ...

Page 25: ...ach of the HD BAR MIC1 GAIN MIC1 AMP MIC2 GAIN and MIC2 AMP items DOWNLOAD LOG Save the unit s log information to the memory card The data is for maintenance UPLOAD DATA BACKUP Save the setting information following data saved in the memory card to this unit z z Items in the OPERATION menu z z Items in the MAINTENANCE menu Excluding however the NETWORK screen VERSION screen SYSTEM screen and SD CA...

Page 26: ...nter http 192 168 0 20 in the Address box of the Web browser If the IP address is changed the URL will also be different If this is the case use the new IP address in the URL http new IP address z z Moving from one menu to another To move from one menu to another select the desired menu on the left of the screen This is equivalent to TOP MENU displayed on the picture monitor When either OPERATION ...

Page 27: ...50i Set the format of the signal to be output from the unit 50 Hz 1080 59 94i 1080 50i SDI RETURN 1 HD SD Set the format of the return signal to be input to HD SD SDI 1 of the RETURN IN connectors SDI RETURN 2 HD SD Set the format of the return signal to be input to HD SD SDI 2 of the RETURN IN connectors SDI OUTPUT 1 2 HD SD Set the format of the signals to be output from 1 and 2 of the HD SD SDI...

Page 28: ... 4 3 aspect ratio Displayed 40 gray outside the area BARS 6 Color bar based on the EIAJ standard that is placed in an area with a 4 3 aspect ratio Displayed 40 gray outside the area Item Setting value Remarks HD BAR LPF OFF 3TAP 5TAP 7TAP 9TAP Select the filter through which to pass the color bar signals to be output from the HD SD SDI OUT connectors when BAR has been selected on the operation pan...

Page 29: ... the SDTV output 0H Sets the vertical phase to the same phase ADVANCE When the field frequency is 59 94 Hz the phase advance is 90H When the field frequency is 50 Hz the phase advance is 75H 0H_SD_DLAY The SDTV signals are delayed and set in phase with the HDTV signals z z When the setting of this item is set to 0H or ADVANCE while the field frequency is 50 Hz images in SD format are delayed by 1 ...

Page 30: ...ich can be used z z Alphanumeric characters z z Spaces z z _ z z When has been input in the character string this part is replaced by the camera number 1 to 19 and displayed Item Setting value Remarks ID2 POSITION V vertical 00 01 05 H horizontal 00 15 Set the display start position of BAR ID2 displayed on the color bars when the color bars are displayed Set from which character in the vertical di...

Page 31: ...nnector 0 5dB increments MIC LEVEL MIC2 40 0dB 0dB 20 0dB Finely adjust the level of output from the MIC OUT 2 connector 0 5dB increments CM DM CM DM Use this to select the type of intercom microphone carbon microphone or dynamic microphone to be connected to the unit CM Carbon microphone DM Dynamic microphone CCU INCOM MIC 40 0dB 0dB 12 0dB Use this to set the level of the unit s intercom microph...

Page 32: ...s ON turning on the power of this unit also turns on the power of the viewfinder REMOTE Starts up in accordance with the VF POWER state that was set with the ROP last time z z ANALOG GAIN Screen This menu is used to set the analog signal levels indicates the factory default setting Item Setting value Remarks COMPOSITE 50 50 Factory setting Set the video level of the analog composite signal to be o...

Page 33: ...PM VIEW SETTING Screen This menu is used to set ON or OFF for the items IRIS status display to display on the picture monitor indicates the factory default setting Item Setting value Remarks CAMERA NO ON OFF Set the display of the camera number CAM MODE ON OFF Set the display of the format of the signal output from the camera SCENE FILE NO ON OFF Set the display of the scene file number SHUTTER ON...

Page 34: ... the lens extender is changed FILTER ON OFF Set the status display for when the filter is changed SCENE FILE ON OFF Set the status display for when the scene file is changed REF LOAD ON OFF Set the status display for when the reference file is loaded AUTO OPERATION STATUS ON OFF Set the status display for when AWB ABB or ASU is executed z z SYSTEM Screen This menu is used to initialize the menu se...

Page 35: ...P 9TAP 7TAP BAR USER1 HD BAR USER1 ARIB 75 WHITE 100 WHITE I_SIGNAL I_SIGNAL 75 WHITE BAR USER2 HD BAR USER2 ARIB 0 BLACK Q_SIGNAL 0 BLACK SETUP 7 5 ON OFF OFF PATHO ON OFF OFF HD SD PHASE pages 13 and 29 HD H PHASE 59 94 Hz 1099 to 1099 50 Hz 1319 to 1319 0 SD H PHASE 59 94 Hz 857 to 857 50 Hz 863 to 863 0 SD HD V SD HD V PHASE 0H ADVANCE 0H_SD_DLAY 0H BAR ID page 20 and 30 BAR ID SWITCH ON OFF O...

Page 36: ...Max 4 characters Characters which can be used z z Alphanumeric characters z z Spaces z z _ 1 ND FILTER2 NAME ND FILTER NAME 2 2 ND FILTER3 NAME ND FILTER NAME 3 3 ND FILTER4 NAME ND FILTER NAME 4 4 NETWORK pages 23 and 33 IP ADDRESS 192 168 0 20 SUBNET MASK SUBNETMASK 255 255 255 0 255 255 255 128 255 255 255 192 255 255 255 224 255 255 255 240 255 255 255 248 255 255 255 252 255 255 255 254 255 2...

Page 37: ...ION STATUS LENS EXT ON OFF ON FILTER MANUAL OPERATION STATUS FILTER ON OFF ON SCENE FILE MANUAL OPERATION STATUS SCENE FILE ON OFF ON REF LOAD MANUAL OPERATION STATUS REF LOAD ON OFF ON AUTO OPERATION STATUS ON OFF ON SYSTEM pages 25 and 34 INITIALIZE SYSTEM DATA NO YES INITIALIZE NO EXECUTE SD CARD page 25 DOWNLOAD DATA BACK UP NO YES NO DOWNLOAD LOG NO YES NO UPLOAD DATA BACKUP NO YES NO UPDATE ...

Page 38: ...n TTL L 24 V 12 R TALLY IN C SYSTEM CCU 13 GND 14 INCOM 2 OUT H CCU SYSTEM 0 dBm 600 Ω 4W 1 V p p RTS z z Select 4W or RTS and INCOM1 or INCOM2 with the INCOM switches on the rear panel When RTS is set terminate pins 14 and 16 of the connector using a terminating resistor 200 Ω 15 INCOM 2 OUT C CCU SYSTEM 16 INCOM 2 GND 17 INCOM 2 IN H SYSTEM CCU 18 INCOM 2 IN C SYSTEM CCU 19 NC 20 NC 21 NC 22 NC ...

Page 39: ...irose Electric Co Ltd Pin No Signal Flow of signals 1 ROP CONT H CCU ROP 2 ROP CONT C CCU ROP 3 ROP DATA H ROP CCU 4 ROP DATA C ROP CCU 5 NC 6 NC 7 NC 8 NC 9 12 V OUT CCU ROP 10 GND 1 2 3 4 5 6 7 8 10 9 Connector of cable HR10A 10P 10P 73 CAMERA AK HCU200P AK HCU200E OPS2404 PR Tajimi Electronics Co Ltd AK HCU200PS AK HCU200ES FXW 3K 93C TLM LEMO Pin No Signal Flow of signals 1 Optical fiber CAM C...

Page 40: ... Screen 22 32 NETWORK Screen 23 33 x x O Operation displays 7 OPERATION menu 35 x x P PM OPERATION STATUS Screen 24 34 PM VIEW SETTING Screen 24 33 x x S SD CARD Screen 25 SETTING1 Screen 11 27 SETTING2 Screen 12 28 START UP Screen 22 32 Status displays 4 5 6 SYSTEM Screen 25 34 x x V VERSION Screen 23 33 x x W WARNING 3 4 Web Site http panasonic net Panasonic Corporation 2012 ...