AJ8 Switches with Trip Function Upgraded Type

–4–

AECTB30E   201811-T

OPERATING PRINCIPLE

• Manual operation is a repetition of (A) and (B). This operation is independent of the electromagnetic reset function.
• The reset mechanism operates only when an electromagnetic reset has occurred. (C)

CAUTIONS FOR USE

Contact

ON

OFF

Iron core

Manual operation

Return spring

Permanent
magnet

Coil

Coil terminal

Electromagnetic reset mechanism

(A)

(B)

(C)

Manual operation

Flips actuator

Manual opening/closing

Electromagnetic reset

 Operating voltage application time

If the rated voltage is applied to the coil 
for more than 10 seconds or the 
maximum voltage is applied for more 
than 1 second, coil performance may 
deteriorate.

 The shape of the mounting panel 

should be as recommended in the 
dimensions diagram.

Please contact us if you are considering 
using a panel of other than the 
recommended size and shape.

 The mounting panel should be made 

of SPCC. If a different material is used, 
its adhesion to the switch unit may not 
be as strong. Check this with actual 
application necessary.

 Note that the actuator could come 

off from the switch housing if 19.6N or 
more of force is applied to the side of 
the actuator.

 Regarding fastening lead wires to 

terminals

1) When connecting the .250 Quick-
connect terminals, use a .250 receptacle 
and insert the terminals straight in.
If you insert them at an angle, the 
terminals could catch on the opening and 
will require greater insertion force.
2) The coil terminals have specific 
polarities. Make sure you connect them 
correctly.

3) Use a receptacle that is compliant with 
JIS C 2809. In addition, there is some 
deviation regarding the insertion force 
depending on the model used from 
different manufacturers, so the insertion 
force should be checked under actual 
conditions.
4) Use TE Connectivity Ltd.’s CT 
connector for the coil terminals.

 Because special receptacle 

terminals are used for the contact 
terminals and the common terminals, 
do not attempt to solder them. Doing 
so could melt plastic components and 
otherwise harm the performance of 
the switch

 The terminals should be connected 

in such a way that they are not under 
constant stress from the connecting 
wires.

 Take care not to drop the product as 

it may impair performance.

 Resistance to chemicals

To clean the switch unit, use a neutral 
detergent diluted with water.
Do not use acidic or alkaline solvents as 
they may damage the switch.
Furthermore, be careful not to get any of 
the detergent solution inside of the switch 
while cleaning it.

 This product is not hermetically 

sealed, so its performance could 
deteriorate under certain ambient 
conditions. Avoid using and storing 
these switches in a location where 
they will be exposed to corrosive 
gases, silicon, or high dust levels, all 
of which can have an adverse effect 
on the contacts. In addition, because 
these switches contain permanent 
magnets, avoid using and storing 
these switches in a location where 
metallic dust, etc., is present.

 When these switches are used with 

weak currents of 500mA or less, a 
layer of material on the surface of the 
contacts may cause contact 
instability. Check and evaluate this 
possibility before using these 
switches under such conditions.

 When using an ON-OFF type switch 

with no (

) indication on the 

actuator, the “OFF” position should be 
indicated on the set in which the 
switch is installed.

 To assure reliability, check the 

switch under actual loading 
conditions. Avoid any situation that 
may adversely affect switching 
performance.

Summary of Contents for AJ8

Page 1: ...V DC AJ8R5001ZCF AJ8R5001ZBCF 12V DC AJ8R5003ZCF AJ8R5003ZBCF 24V DC AJ8R5004ZCF AJ8R5004ZBCF 2 pole Single throw ON OFF 5V DC AJ8R2001ZCF AJ8R2001ZBCF 12V DC AJ8R2003ZCF AJ8R2003ZBCF 24V DC AJ8R2004Z...

Page 2: ...AJ8R5011ZCF AJ8R5011ZBCF 12V DC AJ8R5013ZCF AJ8R5013ZBCF 24V DC AJ8R5014ZCF AJ8R5014ZBCF 2 pole Single throw ON OFF 5V DC AJ8R2011ZCF AJ8R2011ZBCF 12V DC AJ8R2013ZCF AJ8R2013ZBCF 24V DC AJ8R2014ZCF A...

Page 3: ...pprox 19g 2 pole single throw Approx 20g Contact material AgSnO2 alloy Unit mm General tolerance 0 5 The CAD data of the products with a CAD Data mark can be downloaded from our Website CAD Data Exter...

Page 4: ...the insertion force depending on the model used from different manufacturers so the insertion force should be checked under actual conditions 4 Use TE Connectivity Ltd s CT connector for the coil term...

Page 5: ...e used TE Connectivity Ltd s CT connector Reference Receptacle Stripping length of front 5 2 200 10 Black Red UL1007 AWG24 TE Connectivity Ltd s Crimping type 179228 2 Lead wire CT connector Cable wit...

Page 6: ...t Generally this resistance includes the conductor resistance of the spring and terminal portions Vibration resistance Vibration range where a closed contact does not open for longer than a specified...

Page 7: ...rotation is caused during operation Also when using for a load that will cause transient phenomena such as when operating the motor in reverse rotation or switching the poles an arc short circuit shor...

Page 8: ...or sulfide gases may cause a sulfide film or oxide film to form on the surfaces of the contacts and or it may interfere with the functions Check out the atmosphere in which the units are to be stored...

Page 9: ......

Reviews: