background image

–1–

AECTB30E   201811-T

ORDERING INFORMATION

PRODUCT TYPES

Standard actuator color is dark gray and black. To order switches with a black actuator, replace the letter “Z” with “B” in the part 
numbers shown below when ordering.
(Ex.)  AJ8R1001ZC (Actuator color: Dark gray Flange color: Dark gray)

 

 AJ8R1001BC (Actuator color: Black Flange color: Dark gray)

 Without indication on actuators (Actuator color: Dark gray)

Power Rocker Switches 

with an Electromagnetic 

Reset Function

AJ8 SWITCHES WITH TRIP 

FUNCTION UPGRADED TYPE

Poles

Operation type

Coil voltage

Part No.

Flange color: Dark gray

Flange color: Black

1-pole

Single throw (ON-OFF)

5V DC

AJ8R1001ZCF

AJ8R1001ZBCF

12V DC

AJ8R1003ZCF

AJ8R1003ZBCF

24V DC

AJ8R1004ZCF

AJ8R1004ZBCF

Double throw (ON-ON)

5V DC

AJ8R5001ZCF

AJ8R5001ZBCF

12V DC

AJ8R5003ZCF

AJ8R5003ZBCF

24V DC

AJ8R5004ZCF

AJ8R5004ZBCF

2-pole

Single throw (ON-OFF)

5V DC

AJ8R2001ZCF

AJ8R2001ZBCF

12V DC

AJ8R2003ZCF

AJ8R2003ZBCF

24V DC

AJ8R2004ZCF

AJ8R2004ZBCF

FEATURES

• CT terminal adopted for coil terminal
• Long electrical life
• Assures excellent ability to withstand inrush current when 
used to turn a power supply on/off.

AJ

8 R

0

C F

Number of pole and operation
1: 1-pole, single throw (ON-OFF)
2: 2-pole, single throw (ON-OFF)
5: 1-pole, double throw (ON-ON)

Coil voltage
1: 5 V DC
3: 12 V DC
4: 24 V DC

Terminal shape
0: .250 Quick-connect terminal

C: Upgraded type

F: Cadmium-free product

Actuator color
Z: Dark gray
B: Black

Flange color
Nil: Dark gray
B: Black

Function
R: Reset function

Notes: 1. They come with a stamp indicating safety standards without your request.

2. The color of indication on the actuator is white.

Actuator indication
0: No indication
1:         indication
2:         indication

Summary of Contents for AJ8

Page 1: ...V DC AJ8R5001ZCF AJ8R5001ZBCF 12V DC AJ8R5003ZCF AJ8R5003ZBCF 24V DC AJ8R5004ZCF AJ8R5004ZBCF 2 pole Single throw ON OFF 5V DC AJ8R2001ZCF AJ8R2001ZBCF 12V DC AJ8R2003ZCF AJ8R2003ZBCF 24V DC AJ8R2004Z...

Page 2: ...AJ8R5011ZCF AJ8R5011ZBCF 12V DC AJ8R5013ZCF AJ8R5013ZBCF 24V DC AJ8R5014ZCF AJ8R5014ZBCF 2 pole Single throw ON OFF 5V DC AJ8R2011ZCF AJ8R2011ZBCF 12V DC AJ8R2013ZCF AJ8R2013ZBCF 24V DC AJ8R2014ZCF A...

Page 3: ...pprox 19g 2 pole single throw Approx 20g Contact material AgSnO2 alloy Unit mm General tolerance 0 5 The CAD data of the products with a CAD Data mark can be downloaded from our Website CAD Data Exter...

Page 4: ...the insertion force depending on the model used from different manufacturers so the insertion force should be checked under actual conditions 4 Use TE Connectivity Ltd s CT connector for the coil term...

Page 5: ...e used TE Connectivity Ltd s CT connector Reference Receptacle Stripping length of front 5 2 200 10 Black Red UL1007 AWG24 TE Connectivity Ltd s Crimping type 179228 2 Lead wire CT connector Cable wit...

Page 6: ...t Generally this resistance includes the conductor resistance of the spring and terminal portions Vibration resistance Vibration range where a closed contact does not open for longer than a specified...

Page 7: ...rotation is caused during operation Also when using for a load that will cause transient phenomena such as when operating the motor in reverse rotation or switching the poles an arc short circuit shor...

Page 8: ...or sulfide gases may cause a sulfide film or oxide film to form on the surfaces of the contacts and or it may interfere with the functions Check out the atmosphere in which the units are to be stored...

Page 9: ......