X-RADIATION
WARNING
1. The potential source of X-radiation in EVF sets is the High Voltage
section and the picture tube.
2. When using a picture tube test jig for service, ensure that jig is
capable of handling 10kV without causing x-radiation.
Note :
It is important to use an accurate periodically calibrated high voltage meter.
3. Measure the High Voltage. The meter (electric type) reading should
indicate 2.5kV, 0.15kV. If the meter indication is out of tolerance,
immediate service and correction is required to prevent the
possibility of premature component failure. To prevent an x-
radiation possibility, it is essential to use the specified picture tube.