About the Power Supply Cable

Use the power supply cable with the following specifications with the unit.
The extension length of 100 m cannot be maintained between this unit and the camera adapter especially if the resistance 
value is larger than the following specifications.

1) Conductor resistance: 0.5 

h

 or less

(Real cross-section area of the conductor: 3.5 mm

2

)

2) Structure

Number of wires: 4
Cross-section area of each wire: 1.75 mm

2

3) Withstanding voltage

AC 60 V or higher
Real applied voltage: DC 24 V

4) Stranding pitch

Stranding pitch for 4 wires: 110 mm

5)  Finished external dimensions

10 mm or less

6) End connector part numbers

AG-CA300G side: CE01-6A18-11SC-D0

(Manufacturer: DDK Ltd.)

AG-BS300P/E side: CE01-6A18-11PC-D0

(Manufacturer: DDK Ltd.)

7) Part number of cables

DC50V10-CE01PS-SC (50 m)
DC100V10-CE01PS-SC (100 m)
(E48897, AWM 2517  105C  300 V  VW-1, Manufacturer: Canare Electric)

(CE01-6A18-11PC-D0; to the unit)

(CE01-6A18-11SC-D0; to camera adapter)

(E48897, AWM 2517  105C  300 V  VW-1)

3

1

2

4

3

1

2

4

110 mm

Standby

Standby

Standby

Standby

Standby

Standby

GND

24 V

GND

24 V

AG-BS300P_E(VQT2H41)_E.book  18 ページ  2009年10月23日 金曜日 午後6時8分

Summary of Contents for AG-BS300E

Page 1: ...909T0 F Printed in Japan VQT2H41 Model No AG BS300P Model No AG BS300E Before operating this product please read the instructions carefully and save this manual for future use ENGLISH AG BS300P_E VQT2H41 _E book 1 ページ 2009年10月23日 金曜日 午後6時8分 ...

Page 2: ... voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance CAUTION The mains plug of the power supply cord shall remain readily...

Page 3: ...lug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped S3125A FCC Note This equipment has been tested and found to comply with the limits for a class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmfu...

Page 4: ...fitted in this plug Should the fuse need to be replaced please ensure that the replacement fuse has a rating of 13 amps and that it is approved by ASTA or BSI to BS1362 Check for the ASTA mark or the BSI mark on the body of the fuse If the plug contains a removable fuse cover you must ensure that it is refitted when the fuse is replaced If you lose the fuse cover the plug must not be used until a ...

Page 5: ...t WARNING Always keep accessories screws out of the reach of babies and small children CAUTION The mains plug of the power supply cord shall remain readily operable The AC receptacle mains socket outlet shall be installed near the equipment and shall be easily accessible To completely disconnect this equipment from the AC mains disconnect the mains plug from the AC receptacle CAUTION In order to m...

Page 6: ...les which provide quality performance for high frequency transmission applications for analog audio signals z Other connecting cables IEEE1394 USB Use shielded cables which provide quality performance for high frequency applications as connecting cables z When connecting to the DVI signal terminal use a cable with a ferrite core z If your apparatus is supplied with ferrite core s they must be atta...

Page 7: ...has the following features z The unit is connected to the camera adapter AG CA300G optional by a power cable refer to page 18 for specification and two BNC cables and works to supply power to the camera recorder side and transmit the video and audio signals recorded using the camera recorder z It is possible to transfer one line of the return video RET 2 lines of transfer are possible depending on...

Page 8: ...ETOUT AG HPX300 301 302 304 SDI OUT 2 VF return video Dedicatedcable monitor video GPI BT LH80W WU Remote cable control monitor video AG CA300G Anton Bauer Hytron Trimpac AG BS300P E Power supply cable Refer to page 18 Resistance Use 0 5 h or less Maximum extension length 100 m Main line SDI video BNC GENLOCK BNC BNC 2 Use 5C FW Maximum extension length 100 m VIDEO OUT Composite signal Intercom ta...

Page 9: ... turning on the power for this unit when the remote control unit is connected to this unit z Turn on the power after connecting the power supply cable and BNC cables z INCOM becomes disconnected temporarily when the video format is changed on the camera recorder z Video output signal of this unit may be interrupted when the power is turned on but this is not a malfunction z When the video format o...

Page 10: ...gnal by supplying SDI2 output or SDI1 output of the AG HPX300 301 302 304 to the BT LH80W WU and selecting the INPUT SEL SDI in the GPI4 item of the BT LH80W WU z The camera extension system including this unit can send back 2 lines of signals RET SDI signal and RET VIDEO signal of this unit to the camera adapter simultaneously when the video format of the AG HPX300 301 302 304 is HD format The RE...

Page 11: ... display the camera status signal while displaying the video being recorded by the camera recorder on the BT LH80W WU it is possible to change the video being recorded to SDI signal by supplying SDI2 output or SDI1 output of the camera recorder to the BT LH80W WU and selecting the INPUT SEL SDI in the GPI4 item of the BT LH80W WU z The camera extension system including this unit can send back 2 li...

Page 12: ...n the lens is pushed and the signal from the AG HPX500 502 is output when it is not pushed z The R TALLY LED on the viewfinder will light up while recording with the AG HPX500 502 or when the R TALLY signal is supplied to this unit z When the BT LH80W WU is used rather than the viewfinder included with the AG HPX500 502 and the AG YA500G VF connector is connected to the BT LH80W WU VF connector wi...

Page 13: ... can be used Use a 3 meters or less cable 5 INCOM volume level potentiometer This is a potentiometer to adjust the volume level of the intercom 6 MIC switch This is the ON OFF switch for the intercom microphone There are three positions ON OFF PTT PTT Push To talk Microphone is turned on only while pushed 7 TALLY lamp CALL switch This is turned on while the TALLY signal is input to this unit The T...

Page 14: ...onnector This is an input connector for the return video signal from this unit to the camera adapter This will input a SDI signal RET video cannot be viewed on the CRT viewfinder or color viewfinder when the video format for the camera recorder is set to 1080 23 98PsF or 1080 24PsF Note For signals supplied to the 7 RET IN VIDEO signal connector and the 8 RET IN SDI signal connector and the signal...

Page 15: ... output from the 1 DC OUT 24 V connector DC 24 V is output from the 1 DC OUT 24 V connector only when the AC power is supplied to this unit Refer to page 22 17 AC IN connector This is a connector to supply AC power to this unit This is connected to the power outlet using the attached AC power supply cable 18 Cable hook This is used to prevent the AC power supply cable slipping off _ Use of externa...

Page 16: ...Not supported 1080 50i When HD SYNC is supplied 1080 50i 3 value SYNC When SD SYNC is supplied 576 50i black burst signal SYNC burst 1080 24PsF When HD SYNC is supplied 1080 24PsF 3 value SYNC When SD SYNC is supplied Not supported 720 59 94P When HD SYNC is supplied 720 59 94P 3 value SYNC When SD SYNC is supplied 480 59 94i black burst signal SYNC burst 720 60P When HD SYNC is supplied 720 60P 3...

Page 17: ...menu operation of the camera recorder However it is not necessary to set with AG HPX300 301 302 304 and AG HPX500 502 Setting of the GENLOCK PHASE Set the GL PHASE of the camera recorder to GL PHASE HD SDI using the menu operation of the camera recorder If it is used connected to the AG HPX500 502 set the GL SELECT item to SDI and the GL PHASE item to OFF Also set the GL PHASE item to HD SDI When ...

Page 18: ...C 60 V or higher Real applied voltage DC 24 V 4 Stranding pitch Stranding pitch for 4 wires 110 mm 5 Finished external dimensions 10 mm or less 6 End connector part numbers AG CA300G side CE01 6A18 11SC D0 Manufacturer DDK Ltd AG BS300P E side CE01 6A18 11PC D0 Manufacturer DDK Ltd 7 Part number of cables DC50V10 CE01PS SC 50 m DC100V10 CE01PS SC 100 m E48897 AWM 2517 105C 300 V VW 1 Manufacturer ...

Page 19: ...clockwise To decrease the setting value Turn the SEL switch counter clockwise To switch between ON OFF of the setting value Turn the SEL switch clockwise to set ON Turn the SEL switch counter clockwise to set OFF 4 Press the SEL switch Flashing of the setting value will stop and the setting value will be set 5 Repeat steps 3 and 4 to continue to change other settings on the same page 6 To return t...

Page 20: ...ub carrier phase of the VIDEO output connector is performed SC PHASE FINE 75 0 75 Fine adjustment of sub carrier phase of the VIDEO output connector is performed Item Data Saved Variable Range Note GL PHASE HD SDI COMPOSIT Select the output signal to lock the phase to the signal input to the GEN LOCK IN connector HD SDI HD SDI signal will be locked to the GENLOCK input Start position for the video...

Page 21: ... is turned OFF DETAIL LEVEL 0 8 31 Set the level of the detail component for the composite signal output from the VIDEO OUT MENU connector Note Detail signal is added to the menu status and TC display of the camera recorder when the detail level is increased DETAIL CORING 0 1 15 Set the level of the noise elimination level included in the detail component for the composite signal output from the V...

Page 22: ...nufacturer part number HR10A 10P 10PC 73 Hirose Denki Panasonic part number K1AA104H0038 Manufacturer part number HA16RX 4P SW1 76 Hirose Denki Switch DC OUT 24 V 1 Standby 2 GND 3 24 V 4 Standby Standby INCOM TALLY 1 INCOM IN C 2 INCOM GND 3 INCOM OUT C 4 GND 5 6 INCOM IN H 7 INCOM OUT H 8 INCOM GND 9 R TALLY IN 1 2 4 3 3 2 1 4 Panasonic part number K1AY105J0004 Manufacturer part number CE01 2A18...

Page 23: ...5 h For HD SDI compliant to SMPTE292M 299M Standard 1080 59 94i 1080 23 98PsF 1080 24PsF 1080 50i 720 59 94P 720 50P For SD SDI compliant to SMPTE259M C 272M A ITU R BT656 4 standards 480 59 94i 576 50i CA IN BNC 75 h Digital Signal Output Unit SDI OUT1 BNC 0 8 V P P 75 h For HD SDI compliant to SMPTE292M 299M Standard 1080 59 94i 1080 23 98PsF 1080 24PsF 1080 50i 720 59 94P 720 50P For SD SDI com...

Page 24: ...35 481 Panasonic Systems Asia Pacific Broadcast Regional Operation Center 2 Jalan Kilang Barat Panasonic Building Singapore 159346 Tel 65 6270 0110 P 2009 E Information on Disposal for Users of Waste Electrical Electronic Equipment private households This symbol on the products and or accompanying documents means that used electrical and electronic products should not be mixed with general househo...