9.5
Electronic Clutch Function
9-19
9.5.2 Types and Contents of Setting Parameters
For using the electronic clutch, set the following parameters in the "Synchronous parameter
settings" menu.
Parameter name
Description
Clutch setting - Use
Select the operation of the electronic clutch function.
Use / Not use
Clutch
ON
Trigger type
Set an I/O clutch ON request as a trigger to be detected.
Edge selection
Select "Level", "Leading edge" or "Trailing edge" for the method of detecting
trigger signals.
Method
Select "Direct" or "Slip" for the engagement of the clutch.
Slip method
Select "Slip time specification".
Slip time
If "Slip" is selected, set the slip time.
Range: 1 to 10000 ms
Slip curve
selection
Select "Linear".
Clutch
OFF
Trigger type
Select "I/O clutch OFF request" or "Phase after I/O clutch" as a trigger to be
detected.
Edge selection
Select "Disabled", "Leading edge" or "Trailing edge" for the method of detecting
trigger signals.
Phase ratio
Set the ratio for the phase at which the clutch turns off when selecting "Phase
after I/O clutch" for the clutch trigger type.
Range: 0 to 99 (%)
Method
Select "Direct" or "Slip" for the engagement of the clutch.
Slip method
Select “Slip time specification”.
Slip time
If "Slip" is selected, set the slip time.
Range: 1 to 10000 ms
Slip curve
selection
Select "Linear".
(Note 1): "Clutch OFF trigger type" is selectable when "Clutch ON trigger type" is set to "Leading edge" or "Trailing
edge".
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......