5. 

Turn off the handset by pressing the “power” key, and then turn it back on 
by pressing the “power” key. The handset will now be in site survey mode, 
and display signal strength (RSSI) and connection status. Description of the 
values are as follows (PS refers to the handset): 

 

 

6. 

Walk around to confirm the service area. If the readings are acceptable, the 
display will remain green. If the display turns red and the signal is weak, 
install the repeater in the area right before it starts turning red. 
 

7. 

Once the site survey is complete, revert the handset back to normal 
operation. First, turn off the handset. 
 

8. 

Go into Maintenance Mode by following steps 1 to 3. 
 

9. 

Select “Base Monitor” and press “OK”. 

 

 

 

10. 

 Select “OFF” and press “OK”. 

 

 

Summary of Contents for A406

Page 1: ...vices Hosted PBX service from Primus Business Services Before you Start Your Panasonic base unit and cordless phone must be setup turned on and functioning prior to installing the repeater Please refer to the Panasonic TGP600 TPA60 TPA65 Quick Setup Guide available at www primus ca hpbxguide for more information Registering the Repeater to the TGP600 Base Unit 1 Plug the AC adapter into the repeat...

Page 2: ... repeat the step The next step must be completed within 90 seconds 3 Plug the AC adaptor of the repeater to an electrical outlet 4 On the repeater the STATUS indicator and indicator will turn amber for 2 seconds When both indicator lights turn solid green the repeater is registered to the base unit and is ready to use 5 On the base unit exit registration mode by pressing the Handset locator button...

Page 3: ... For wall mount instructions see Panasonic DECT Repeater Installation Manual for the KX A406 available at http primus ca business hpbxguide For additional troubleshooting tips please review the Hosted PBX Small Office Basic Troubleshooting Guide available at http primus ca business hpbxguide If the configuration process was interrupted or if you need assistance please contact Primus HPBX Technical...

Page 4: ...to the same ID On the destination repeater 1 First check the ID of the repeater you are attempting to register to destination repeater With the destination repeater turned on and functioning normally press the PROGRAM button located under the destination repeater Note the number of times the indicator flashes green This is the ID of the destination repeater one flash indicates the ID as 1 two flas...

Page 5: ...STATUS indicator and the indicator will turn amber for 2 seconds and then the STATUS indicator will start flashing red indicating that the repeater is waiting to be found On the base unit 7 On the base unit press and hold the Handset locator button for 4 seconds until the STATUS indicator flashes red 8 Once the destination repeater finds the origin repeater the STATUS indicator on the origin repea...

Page 6: ...tennas of mobile phone cell stations avoid putting the repeater on a bay window or near a window away from objects that could interfere with reception such as wire fences thick walls radiators and metal shelving The repeater is for indoor use only To optimize the placement of your repeater 1 Use the signal strength indicator on the TGP600 TPA60 cordless handset to determine a viable location where...

Page 7: ...NASONIC A406 REPEATER QUICK SETUP GUIDE walk to various areas where you may be using the phone and confirm there is adequate signal strength If not you may need to adjust the position of the repeater or install another repeater to further extend coverage area ...

Page 8: ...rate in maintenance mode 1 Press and hold the power key on the cordless handset until the background of the display screen is light grey 2 Release the power key and press and hold the talk key for about 10 seconds until the background of the display screen turns dark grey 3 Release the talk key and press the following keys in sequence Left soft key 8 1 The display will show Maintenance Mode with t...

Page 9: ...cription of the values are as follows PS refers to the handset 6 Walk around to confirm the service area If the readings are acceptable the display will remain green If the display turns red and the signal is weak install the repeater in the area right before it starts turning red 7 Once the site survey is complete revert the handset back to normal operation First turn off the handset 8 Go into Ma...

Page 10: ...10 PRIMUSBUSINESS CA PRIMUS BUSINESS SERVICES HOSTED PBX PANASONIC A406 REPEATER QUICK SETUP GUIDE 11 Turn the handset off and then turn it back on The handset will be in normal operation mode ...

Page 11: ...ase unit or another repeater if connected in series Flashing Red The repeater is not registered to the base unit Off The repeater power is off Signal Strength ID Indicator Solid Green Signal strength of the base unit is strong Flashing Green The base unit is in repeater range The number of flashes indicates the current ID of the repeater When it flashes once the ID is 1 Solid Amber Signal strength...