Chapter 1. Installation
1.4.2.1
Applicable Standards and Directives
When the HygroPro
II
is installed in hazardous areas with potentially explosive atmospheres, it complies with the ATEX
2014/34/EU equipment directive, the EU standards listed in Table 3 below, and the North American FM/CSA and IEC
standards listed in Table 4 below.
1.4.2.2
Compliance Requirements
The HygroPro
II
installation must comply with EN 60079-14 standard in Europe and with the National Electrical Code
(ANSI/NFPA 70) or part one of the Canadian Electrical Code (C22.1), as applicable, in North America. In other regions,
additional local codes may also apply.
1.4.2.3
Electrical Connections
The HygroPro
II
transmitter is certified intrinsically safe for use in Zone 0. However, the external power must be
provided by one of the following methods:
• an isolated, intrinsically safe, 24 VDC power supply mounted in the safe area
• an isolated Zener barrier mounted in the safe area and installed between a standard 24 VDC power supply and
the HygroPro
II
Refer to Figure 12 on the next page for a typical hazardous (classified) area HygroPro
II
wiring diagram. This
installation uses an MTL706 Zener barrier, in accordance with the second option listed above.
Table 3: European Union (EU) Standards
Title
Number
Date
Electrical apparatus for explosive gas atmospheres: Part
0: General Requirements Equipment
EN/IEC 60079-0
2018
Explosive atmospheres: Part 11: Equipment Protection by
intrinsic safety “i”
EN/IEC 60079-11
2012
Degrees of Protection Provided by Enclosures (IP Code)
EN/IEC 60529
2013
Table 4: North American Standards
Title
Number
Date
Electrical Equipment for Use in Hazardous
(Classified) Locations General Requirements
Class No. 3600
2021
Intrinsically Safe Apparatus and Associated
Apparatus for use in Class I, II, & III, Division 1, and
Class I, Zone 0 & 1 Hazardous (Classified) Locations
Class No. 3610
2021
Electrical and Electronic Test, Measuring and Process
Control Equipment
Class No. 3810
2021
Non-incendive Electrical Equipment for Use in Class I,
Division 2, Hazardous Locations.
CSA-C22.2 No. 213
R2013
Safety requirements for electrical equipment for
measurement, control and laboratory use – Part 1:
General requirements (Adopted IEC 61010-1:2001, MOD)
(Tri-National standard, with UL 61010-1 and ISA 82.02.01)
CSA-C22.2/UL No.
61010-1
2012
Degrees of Protection Provided by Enclosures (IP Code)
ANSI/IEC 60529
2004
Degrees of Protection Provided by Enclosures (IP Code)
CSA-C22.2 No. 60529
R2016
Summary of Contents for HydroProII
Page 1: ...panametrics com 910 331 A November 2022 HygroProII Moisture Transmitter User s Manual...
Page 2: ......
Page 4: ...ii no content intended for this page...
Page 12: ...Preface x HygroProII User s Manual no content intended for this page...
Page 42: ...Chapter 2 Operation 30 HygroProII User s Manual no content intended for this page...
Page 52: ...Chapter 4 Specifications 40 HygroProII User s Manual no content intended for this page...
Page 102: ...Warranty 90 HygroProII User s Manual no content intended for this page...
Page 103: ......