CAUTION:

 Only for use with 15 Amp branch circuits utilizing 14 or 12 gauge wire.  Make sure the branch circuit is de-energized before installation.

1690 Corporate Circle, Petaluma, CA 94954    •   Fax 707-283-5901   •   www.panamax.com

INS0735 REV. D         12/03

5

BAY
  1

BAY
  2

BAY
  3

STEP 6:

Connect the signal cables to the appropriate Max In-Wall module (sold separately) and slide the 
module into the opening. The module can be installed to three different depths, from flush to 
full recess.  To remove the module, use the tool included with the module.

NOTE:

  The signal-line module shown is for illustration purposes, and is not included with the 

base unit.  A variety of modules are sold separately.  This product must be used with the blank 
module cover interface, or a signal-line module installed.

2

3 3/4 in.

4 in.

6 1/4 in.

2

3 3/4 in.

STEP 1:

Select a location close to the display device (Plasma TV, DLP, etc.).  In the 
case of a wall-mounted Plasma TV, this may be behind the display device 
and totally hidden from view once the Plasma TV is mounted.

MIW-Power NOTE:

 For new construction (pre-wire): Use a Carlon new-

work electrical box (Model B122A).  A Carlon low voltage add-on bracket 
(Model SC1 OOSC) may be used with the new-work box to indicate the 
size and location of the opening needed in the drywall.  The low-voltage 
bracket may be left in place when installing the MIW-Power.  

MIW-Power-3Bay NOTE:

 For new construction (pre-wire): Use a Carlon 

new-work electrical box (Model B122A).  Carlon low-voltage add-on 
brackets cannot be used since there is no way to remove them after the 
drywall is installed.  The width of the opening in the drywall will have to 
be enlarged (carefully) to allow installation of the 3-bay unit.

STEP 2:

Run the AC wires through the lower-left entry of the outlet box.  No more than 1 inch of wire sheath should extend into the outlet box.  
3 inches of wire should be able to extend beyond the opening of the outlet box.  Install the outlet box into the right side of the hole. 

• For MIW-POWER, cut a 
4-inch wide by 3 3/4 - inch 
high hole in the wall.

• For MIW-POWER-3BAY, 
cut a 6 1/4 - inch wide by 
3 3/4 - inch high hole.

STEP 3:

Slide the included shrink-wrap 
tubing over the ground wire to 
prevent contact with the circuit 
board.  Use the included wire
 nuts to connect the wires.

STEP 4:

Remove the blank module interface 
cover and run the signal cables 
through the opening.  

The MIW-Power-3Bay will accommodate up to 3 modules 
and includes 3 separate blank cover plates.  Remove only 
the ones being replaced with signal-line modules.

STEP 5:

Neatly fold the AC wires as you install the protector into the wall with 
the AC side fitting into the outlet box. Secure the unit to the outlet 
box with the included screws.

MIW-Power NOTE:

  Only the right side screws are 

used to mount the protector into the included outlet 
box. The left side screws are for appearance only 
and are held on with the included plastic washers.  
All four screws are used when mounting the protector 
to a new-work electrical box and add-on bracket.

MIW-Power-3Bay NOTE:

  

The right side screws are used to 
mount the protector into the 
included outlet box.
The leftside screws and compression 
brackets secure the module bay 
portion of the unit to the drywall 
and provide support for the weight 
of the signal-line cables.

6