background image

   VOLTAGE SENSE 

TRIGGER INPUT

15 AMP CIRCUIT 

BREAKER

GROUND

LUG

CATV / ANT

PHONE

LAN

3 - 24VDC

LINE IN                EQUIP.             LINE IN           EQUIP.    

MAIN POWER

120 VAC/15A

BANK 3

HIGH CURRENT

SUB / AMP                               RECEIVER

DVD                                          CD

PRE-AMP                                 AUX / VCR

BANK 2

SWITCHED

HD CABLE / SA

T                     HDTV / MONITOR

DIGIT

AL RADIO                                DVR

BANK 1

ALWAYS ON

DELAY ON

SAT

POWER AND FILTRATION

BANK 1 

ALWAYS ON

BANK 2

ON 

BANK 3

ON

WIRING 

OK

90V   95V   100V  105V  110V  115V   120V  125V  130V  135V

METER
LIGHTS

M5100-EX

Home Theater Power Conditioner

Power Button

Press and hold for 2 sec-
onds to turn Bank 2 and
Bank 3 outlets ON or OFF.
This switch is bypassed if
the rear panel DC Trigger
input is being used.

Power LEDs

Indicates the status of the rear panel
outlets.  LEDs for each outlet bank
will be lit when the outlets are turned
ON.  They will flash during the start-
up and shutdown process.

Circuit Breaker

Automatically opens
when the current load
is greater than 15
Amps.  Push to reset.

Ground Lug

Provides a common
grounding point for
equipment with sep-
arate ground leads.

Main Power

Must be plugged
into a properly
wired & ground-
ed 3-wire outlet

Wiring OK LED

Normally On.  Indicates
that the wall outlet is
properly grounded and
Line/Neutral polarity is
correct.

Meter Dimmer

Pushbutton control for
meter LED brightness.
Cycles between Off,
Low, Medium and High.

Convenience 
Outlet

Provides a quick con-
venient way to plug in
components such as
camcorders and video
game systems.

Outlet Bank 1 

Four always on outlets.

Power will only be

turned off under a fault condition.  (See speci-
fications for over-voltage and under-voltage
thresholds)  Power is cleaned by a two-stage
balanced Pi filter which also provides noise
isolation from Outlet Banks 2 and 3.

Outlet Bank 2

Four switched outlets

controlled by the

front panel Power Button or the DC Trigger
input.  Bank 2 will turn on immediately and
turn off after 10 seconds.  EMI/RFI noise fil-
tration is provided by a two-stage balanced
Pi filter which also provides noise isolation
from Outlet Banks 1 and 3.

Outlet Bank 3

Two switched, high current outlets

controlled

by the front panel Power Button or the DC
Trigger input.  Bank 3 has a 5 second turn on
delay and turns off immediately.  The High
Current outlet provides power from a low
impedance noise filtration circuit that does not
limit the current to your equipment.  Its output
is noise isolated from all other outlet banks.     

Voltage Sense Trigger Input

3.5mm (1/8”) Mini-Plug jack.
Connect to a remote trigger device
that uses a DC output to trigger a
startup/shutdown sequence.  This
bypasses the front panel power
switch.  

Important, Please Note:

The unit needs to be plugged in,
and in the powered OFF state
before inserting the DC input trig-
ger mini-plug.

LAN Jacks

Protection circuits
for 10/100 baseT
Ethernet lines.
Incoming LAN line

MUST 

be plugged

into the 

LINE

jack.

Patch cord to the
equipment 

MUST

be plugged into
the 

EQUIP

jacks.

Phone Jacks

Protection circuits for
standard telephone or pay-
per-view lines.  Phone cir-
cuit is auto-resetting.
Incoming phone cord

MUST 

be plugged into the

LINE

jack.  Patch cords to

the equipment (satellite
receiver, digital video
recorder, telephone, etc.)

MUST

be plugged into the

EQUIP

jacks.

Satellite TV 
Coax Jacks

Bidirectional protection cir-
cuit optimized for satellite
TV signal lines.  

Do not use

for cable TV off-air anten-
nas and cable modems.

Cable TV Coax Jacks

Bidirectional protection cir-
cuit optimized for cable TV,
off-air antennas and cable
modem signal lines.  

Do not

use for Satellite TV.

Voltmeter

Ten segment LED voltmeter indicates
voltages between 90–135VAC.  If line
voltage drops below 90VAC, the first LED
will flash slowly to indicate an under-volt-
age condition.  If line voltage exceeds
145VAC, the first 9 LED’s turn off and the
last LED (Red) will flash slowly to indi-
cate an over voltage condition

M5100 -EX Back Panel Connection Features

M5100 -EX Front Panel Features

Note to CATV Installers:

This reminder is provided to call attention to Article 820-40 of the NEC.  That article provides specific
guidelines for proper grounding.It specifies that the cable ground shall be connected to the grounding
system of the building and as close to the point of entry as practical.