background image

1

© 2007 PANAMAX, INC.  All Rights Reserved.

PANAMAX, the Panamax logo and MAX are registered US trademarks of Panamax.   

ACRegenerator, Firewall for Noise, Protect or Disconnect and SignalPerfect are trademarks of PANAMAX. 

SIDACtor is a registered US trademark of Teccor Electronics, Inc.   TiVo is a trademark of TiVo, Inc.

MODEL:  M7500-PRO

IMPORTANT SAFETY INSTRUCTIONS

1.

Read these instructions.

2.

Keep these instructions.

3.

Heed all warnings.

4.

Follow all instructions.

5.

WARNING:

Do not use this apparatus near water. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. 

6.

Clean only with dry cloth.

7.

Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 

If the M7500-PRO is installed in a rack, this

“blank” must be installed directly below the M7500-PRO to ensure proper ventilation.

8.

Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

9.

Do not defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one wider than the other. A grounding

type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit

into your outlet, consult an electrician for replacement of the obsolete outlet.

10.

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the

apparatus.

11.

Only use attachments/accessories specified by the manufacturer.

12.

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply

cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not

operate normally, or has been dropped.

13.

Where the power cord is used as the main disconnect device, the disconnect device shall remain readily accessible.

14.

This device must be connected to a main socket outlet with a protective earthing connection.

MAX

®

7500-PRO Home Theater Power Management Owner’s Manual

M7500-PRO

POWER FILTRATION AND 

REGULATION ACTIVE          

           HIGH CURRENT

 GROUND

ISOLATION

ACTIVE

BANK 1 ON       BANK 2 O

N       BANK 3 ON       BANK 4 ON     

     BANK 5              BANK 

 HC 1 ON           HC 2 ON

BRIGHTNESS 

PRESS: 

METER SELECT

Home Theater 

Power Manageme

nt

AUTO

Summary of Contents for M7500-PRO

Page 1: ...utilized during the develop ment of this model The MAX 7500 PRO has been specifically engi neered to enhance the performance and life expectancy of high end Audio Video entertain ment gear The combina...

Page 2: ...phone Line Protection 7 AC Surge Protection 7 AVM Automatic Voltage Monitoring Protection 7 Automatic Over Under Voltage Protection 7 Technical Specifications 8 RS 232 Command Specification 9 10 11 12...

Page 3: ...ider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet c...

Page 4: ...ence in both common and nor mal modes Cross contamination between your components is also eliminated with this design High Current Components One bank of individually switched outlets bank 5 specifica...

Page 5: ...R HOME AUTOMATION CONTROL DVD UNIVERSAL COAX PROTECTION 1 3 2 UNIVERSAL COAX PROTECTION 4 BANK 1 ALWAYS ON BANK 2 SWITCHED BANK 3 SWITCHED BANK 4 SWITCHED BANK 5 HIGH CURRENT GROUND LUG 15 AMP CIRCUIT...

Page 6: ...trigger device that uses a DC voltage signal to initiate a startup shut down sequence 11 DC Trigger Output 3 5mm 1 8 Mini Plug jack The M7500 Pro generates its own 12VDC trigger to control another de...

Page 7: ...fiers and powered subwoofers to work to their full potential When the movie thunders with a terrific explosion or when the music reaches a climac tic crescendo an amplifier has to rapidly draw large a...

Page 8: ...s a standard 3 5mm mono mini plug jack Modes of Operation The MAX 7500 Pro offers two modes of operation selected using the Switch Settings Custom Settings switch In the Switch Settings mode all of th...

Page 9: ...8 LAN TEL AC Surge Protection When the MAX 7500 Pro is subjected to a high volt age surge its voltage output is limited to a safe level and the high levels of surge current are diverted away from the...

Page 10: ...Short circuit protection Yes Delay on output 10 seconds DC TRIGGER OUTPUT UNIVERSAL CABLE SATELLITE CIRCUIT TELEPHONE CIRCUIT LAN CIRCUIT AC POWER Line Voltage 120V 60Hz Regulation Range 100V 135V Reg...

Page 11: ...l button to OFF Turns on all outlets Turn on is immediate with no delay Terminates any running turn on or turn off sequence Overrides the DC trigger input Changes the status of the front panel button...

Page 12: ...GOUT triggersource NONE BUTTON TRIGIN where NONE Outlet bank is always ON trigger output is OFF RS232 only BUTTON Trigger on front panel button TRIGIN Trigger on DC input trigger Example SET_TRIGGER 3...

Page 13: ...mode linefeed mode to their original factory settings listed below Resets the configuration below TRIGGER FOR 1 BUTTON TRIGGER FOR 2 BUTTON TRIGGER FOR 3 BUTTON TRIGGER FOR 4 BUTTON TRIGGER FOR HC1 BU...

Page 14: ...FF CR BANK1 status CR BANK2 status CR BANK3 status CR BANK4 status CR HC1 status CR HC2 status CR TRIGOUT status CR status ON OFF if input voltage is within limits PWR NORMAL CR during overvoltage PWR...

Page 15: ...CR BRIGHTNESS x CR FEEDBACK x CR LINEFEED x CR QUERIES continued RESPONSES AND WARNING MESSAGES If unsolicited feedback is enabled the following warning messages will be transmitted under the conditi...

Page 16: ...p the buzz is to find the source of the distur bance most likely a quartz lamp and plug it into a different branch circuit Panamax Technical Support will be glad to help you if you have any questions...

Page 17: ...D EQUIPMENT PROTECTION POLICY DOES NOT APPLY TO THE PANAMAX CONNECTED EQUIPMENT PROTECTION POLICY DOES NOT APPLY TO Service charges installation costs reinstallation costs setup cost diag nostic charg...