AC Power
Line Voltage:____________________________________________________120V, 60Hz
Total Current Capacity:__________________________________________________15 A
UL1449 Suppression Rating:____________________________________________330V
Protection Modes:______________________________________________L-N, L-G, N-G
Initial Clamping Level:_________________________________________________200V
Energy Dissipation:______________________________________________1650 Joules
Peak Impulse Current:___________________________________________52,000 Amps
Catastrophic Surge Circuit:_______________________________________________Yes
Thermal Fusing:_______________________________________________________Yes
Over-voltage shutoff:__________________________________________142 VAC ±5 VAC
Under-voltage shutoff:_________________________________________84 VAC ± 6 VAC
EMI/RFI Noise Filtration
Bank 1, High Current Outlet: ___________________________ 49 db, 100 KHz - 2 MHz
Bank 1, Always ON Outlets:____________________________ 61 db, 100 KHz - 2 MHz
Bank 2, Switched Outlets:_____________________________ 60 db, 100 KHz - 2 MHz
Common Mode (all banks)____________________________ 60 db, 100 KHz - 2 MHz
Telephone Circui
t
(pay-per-view)
Fuseless/Auto-resetting:_________________________________________________Yes
Clamping Level:______________________________________________________260V
Capacitance:__________________________________________________30pf (approx.)
Suppression Modes:____________________________________Metallic & Longitudinal
Jacks:
LINE:_____________________________________________RJ-45 (RJ-11 compatible)
Wires Protected:________________________________________2-Wire, Pins 4 & 5
EQUIP 1:__________________________________________RJ-45 (RJ-11 compatible)
Wires Protected:________________________________________2-Wire, Pins 4 & 5
EQUIP: 2__________________________________________________________RJ-11
Wires Protected:________________________________________2-Wire, Pins 3 & 4
DSL Compatible:_______________________________________________________Yes
LAN Circuit
Clamping Level:____________________________________________________8V ± 2V
Jacks:_____________________________________________________________RJ-45
Wires Protected:_______________________________________4-Wires, Pins 1, 2, 3 & 6
HD Satellite TV Circuit
Bidirectional:__________________________________________________________Yes
Shielded:_____________________________________________________________Yes
Clamping Level:_______________________________________________________27V
Attenuation:_____________________________________< 1db from 950MHz - 2.05GHz
< 2.4db @ 2.2GHz
Connections:__________________________________________Female “F”, Gold Plated
HD Cable TV Circuit
Bidirectional:__________________________________________________________Yes
Shielded:_____________________________________________________________Yes
Clamping Level:_______________________________________________________1.4V
Attenuation:________________________________________< 1db from 5MHz - 950MHz
Connections:__________________________________________Female “F”, Gold Plated
Pay-Per-View Compatible________________________________________________Yes
MODEL M4300-EX UNIT CARTON
MASTER CARTON
Dimensions
Weight
Dimensions
Weight UPC Qty Dimensions Weight
UPC
17" x 7.25" x 1.75"
6.5 lbs
19.5" x 12.125" x 5.25" 9.5 Lbs 0 50616 00784 9 4 26.6" x 20" x 11.25" 40 Lbs 5 00 50616 00784 4
2.125" H with feet
UPC’s, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING
OPTIONAL SILVER BEZEL
SILVER BEZEL
PRODUCT
UNIT CARTON
MASTER CARTON
Model # Dimensions
Weight Dimensions Weight
UPC
Qty Dimensions
Weight
UPC
BEZ4300-EXS 17" W x 0.625" D x 1.75" H 14.5 Oz 18" x 4" x 1" 18.0 Oz 0 50616 00791 7 N/A N/A N/A N/A
1690 Corporate Circle, Petaluma, CA 94954
•
800-472-5555 or 707-283-5900
•
Fax - 707-283-5901
•
www.panamax.com
The Power Specialists Since 1975
®
MAX
®
4300-EX REAR PANEL FEATURES
MAX
®
4300-EX SPECIFICATIONS
Specifications subject to change due to product upgrades and improvements.
Circuit Breaker
Automatically opens
when the current load is
greater than 15 Amps.
Ground Lug
Provides a common
grounding point for
equipment with sep-
arate ground leads.
Main Power
Must be plugged into a
properly wired and
grounded 3-wire outlet
Outlet Bank 1
Four always on outlets.
Power will only be turned
off under a fault condition. (See specifications for
over-voltage and under-voltage thresholds)
Outlet Bank 1 (continued)
The
High Current outlet
provides power from a non-inductive noise fil-
tration circuit that does not limit the current to your equipment. Its out-
put is noise isolated from all of the other outlets. Power from the other
three always on outlets is cleaned by a two-stage tapped Pi filter circuit
which provides noise isolation from both the High Current outlet and
Outlet Bank 2.
Outlet Bank 2
Four switched outlets
controlled by the front panel Power
Button. EMI/RFI noise filtration is provided by a two stage
tapped Pi filter circuit which also provides noise isolation
from all four outlets in Bank 1.
LAN / Phone Jacks
Protection circuits for 10/100
baseT Ethernet and standard
telephone or pay-per-view lines.
Phone circuit is auto-resetting.
Satellite TV Coax Jacks
Bidirectional protection circuit opti-
mized for satellite TV signal lines.
Rack Mountable
(rack mount kit not included and sold separately - Rack Mount Kit Single DIN, Part #
GRM2205)
Cable TV Coax Jacks
Bidirectional protection circuit
optimized for cable TV, off-air
antennas and cable modem
signal lines.
© 2006 Panamax, Inc. Panamax, MAX and the Panamax logo are registered US trademarks of Panamax. Protect or Disconnect is a trademark of Panamax. SIDACtor is a registered US trademark of Teccor Electronics, Inc.