background image

CV2 

Instruction Sheet and Manual

 

Summary of Contents for BlueBolt CV2

Page 1: ...CV2 Instruction Sheet and Manual ...

Page 2: ...of this product for a period of three 3 years from the date of purchase that the unit shall be free of defects in design material or workmanship and Panamax Inc will repair or replace any defective unit Full warranty information is available online at www Panamax com or www FurmanPower com FCC CLASS B DIGITAL DEVICE INFORMATION NOTE This equipment has been tested and found to comply with the limit...

Page 3: ...led properly The Link light should be illuminated solid green and the Activity light should be blinking intermittently green C Is your Internet connection functioning Can you access a general web page D Is your BlueBOLT CV2 card connected to your internet router or modem Check the Ethernet cable and confirm that the unit is connected to an active Internet connection and make sure those connected d...

Page 4: ...REA NETWORK OPERATION CONVENTIONS Bold italic font indicates variable text XML attributes can be enclosed in double quotes or single quotes There is no difference between the two DEFINITIONS Device The end user product that the BLUEBOLT CV2 card is installed into CV2 Abbreviated nomenclature for BLUEBOLT CV2 ...

Page 5: ...port 57010 Messages to the CV2 are structured in XML Responses are also structured in XML XML messages are wrapped in the header xml version 1 0 device class cv2 id 1065a3xxxxxx MESSAGE device Where xxxxxx is the last six digits of the assigned MAC address MESSAGE is the content of the message For brevity the XML wrapper will not be included in the description of individual messages The CV2 card a...

Page 6: ...ase 10 decimal value info CV2 DEVICE STATUS QUERY Query CV2 connected device status SEND command sendstatus command RECEIVE status time time Response time stamp provided in UNIX time ntwkinvhash HASH ntkwkinvhash Unique configuration code for the connected device This will change if the BlueBOLT CV2 card gets installed into a to a different device linkstate LINK linkstate 0 No communication with c...

Page 7: ... reboot the conected device SEND command reboot command RECEIVE None No response BLUEBOLT CV2 card reboots Does not reboot the connected device M4315 PRO M4320 PRO COMMANDS Messages to and from the M4315 20 PRO device are similarly structured in XML The XML messages are wrapped in the header xml version 1 0 device class km4315 id device_id MESSAGE device The device class and ID are discovered by i...

Page 8: ...V UV fault 1 OV UV fault wiringfault WF wiringfault Outlet wiring fault status 0 No wiring fault 1 Wiring Fault bkrfault BKR bkrfault Circuit breaker status 0 Normal 1 Breaker tripped lastseqstate SEQ lastseqstate Last sequence state 0 turn OFF sequence 1 turn ON sequence trigger TRIG trigger DC trigger status 0 trigger inactive 1 trigger active temperature TEMP temperature Internal temperature de...

Page 9: ...ime profile PROFILE profile Active outlet trigger delay profile 1 Profile 1 factory default 2 Profile 2 3 Profile 3 4 Profile 4 dlys dly id outlet sf off so on cy id outlet CYCLE cy dlys Outlet bank delay settings outlet outlet number on sequence OFF delay off sequence ON delay CYCLE power cycle delay grps dcin OUTLETS dcin butt id button OUTLETS butt grps DC Trigger Button Input Groups OUTLETS af...

Page 10: ...t 1 1 1 1 1 0 0 0 0 Indicates that DC trigger is assigned to outlets 8 7 6 and 5 Example 3 grps butt id 1 8a butt grps The hex value 8a converted to binary is 1000 1010 where each bit represents an outlet affected by Button 1 Bit 7 Outlet 8 Bit 6 Outlet 7 Bit 5 Outlet 6 Bit 4 Outlet 5 Bit 3 Outlet 4 Bit 2 Outlet 3 Bit 1 Outlet 2 Bit 0 Outlet 1 1 0 0 0 1 0 1 0 SWITCH OUTLET COMMAND Command to switc...

Page 11: ...on Get Device Settings CYCLE OUTLET COMMAND Command to power cycle an individual outlet Example to power cycle outlet 6 command cycleoutlet id 6 command CYCLE OUTLET GROUP COMMAND Command to power cycle a group of outlets SEND command cycleoutlet id outlet command outlet outlet number to power cycle RECEIVE None No response SEND command cycleoutlets grp outlets command outlets affected outlets bit...

Page 12: ...TS dcin butt id button OUTLETS butt grps Set input Groups DC Trigger Button Input Groups OUTLETS affected outlets bitmap expressed as a hexadecimal value LSB bit 0 represents outlet 1 bit 7 represents outlet 8 button 1 Power cycle outlet with button 1 button 2 Power cycle outlet with button 2 button 3 Force outlet on off with Button 1 AND Button 2 Examples To set the configuration to preset profil...

Page 13: ...D above Note The device_id will change if the CV2 card is moved to another BlueBOLT compatible product For brevity the XML wrapper will not be included in the description of individual messages DEVICE DEVICE CLASS Panamax MB1500 kmb1500 Furman F1500 UPS kf1500 Furman F1500 UPS E kf1500e GET DEVICE INFORMATION QUERY Query the firmware version of the connected MB1500 F1500 UPS F1500 UPS E SEND comma...

Page 14: ...00 UPS firmware version voltage Input line voltage Vac voltageout Output line voltage Vac amperage Input current Amps wattage Real Power Watts pwrva Apparent Power VA powerfact Power factor pwrcond Power condition Normal Recovery Under voltage Over voltage battlevel Remaining battery charge 0 0 1 0 loadlevel Load capacity used 0 0 1 0 outlet id n OSTATE outlet Outlet n status OSTATE 0 Outlet n OFF...

Page 15: ...ightness bright brightness Display Brightness bright 0 25 0 5 0 75 1 00 scroll time scroll Scroll Mode time 5 10 seconds 0 OFF sleep time sleep Sleep Mode time 30 60 seconds 0 OFF normvolt voltage normvolt Normal Voltage Setting F 1500UPS E ONLY voltage 220 220 Vac operation voltage 230 230 Vac operation voltage 240 240 Vac operation settings SWITCH OUTLET COMMAND Command to switch an individual o...

Page 16: ...TE 1 switch outlet ON RECEIVE None No response Example switch ON outlets 2 and 4 command outlets grp 0a 1 outlets command Bit 7 N A Bit 6 N A Bit 5 N A Bit 4 N A Bit 3 Outlet 4 Bit 2 Outlet 3 Bit 1 Outlet 2 Bit 0 Outlet 1 0 0 0 0 1 0 1 0 CYCLE OUTLET COMMAND Command to power cycle an individual outlet SEND command cycleoutlet id outlet command outlet outlet number to power cycle RECEIVE None No re...

Page 17: ... 1 0 0 0 0 0 0 1 1 SEND command set MESSAGE set command RECEIVE None SETTING PARAMETERS avr mode avr Set Automatic Voltage Regulation Mode mode 0 OFF mode 1 Standard mode 2 Sensitive battthresh id n thold battthresh Set Non critical outlet battery threshold n outlet bank 3 or 4 thold outlet bank n will shut off when the battery storage drops below this value 0 0 1 0 buzzer mode buzzer Set Buzzer M...

Page 18: ...18 EMBEDDED WEB STATUS PAGE Meters Conditions ...

Page 19: ...19 CONTROLS PAGE Outlet Groups Individual Outlets ...

Page 20: ...20 CONFIGURATION PAGE The configuration page is where you make your network attached device and password protection settings ...

Page 21: ...CV2 card into your browser You can locate the Local IP Address by clicking on Device Admin within the BlueBOLT user interface This will take you to the embedded web page of the BlueBOLT CV2 Note You must be on the same network as the BlueBOLT CV2 to view the embedded web page Once you are logged into the embedded webpage of the BlueBOLT CV2 click on Configuration ...

Page 22: ...22 Input a user name and password check the box for Password Protection Enabled and click the Update Password button ...

Page 23: ... have enabled the password protection your browser will prompt you to sign in using the new admin and password Depending on your browser you may need to refresh the page if the log in screen flashes of the screen ...

Page 24: ...ontrol 5919 Sea Otter Place Carlsbad CA 92010 760 438 7000 800 421 1587 www nortekcontrol com www panamax com www furmanpower com 2019 Nortek Security Control All rights reserved Panamax BlueBOLT and Furman are trademarks of Nortek Security Control ...