C3-IP Quick Start Guide

POWER

Blue Flashing quickly:

 Switch/breaker is off or tripped .

Blue Flashing slowly:

 Indicates that a power sequence or 

power cycle is in progress .

Blue On:

 Outlets are on .

PROTECTION OK

Green off:

 Power is on, and the surge protection fuse is intact .

Green off with switch/breaker on

 indicates that surge protection fuse is blown OR 

Green off with switch/breaker off or during over/undervoltage event:

 inconclusive

UNSAFE VOLTAGE

ON during Overvoltage or Undervoltage event .

BLUEBOLT

Green flashing:

 Acquiring IP address via DHCP .

Green solid: 

IP address acquired (

Note:

 it does not stay in this state very long before 

going to establish communication with BlueBOLT .)

Blue flashing: 

Attempting to establish communication with BlueBOLT .

Blue solid: 

Communication with BlueBOLT established .

Your C3-IP can be controlled and monitored from anywhere in the world using the
BlueBOLT cloud .

On-Line Registration

 – The C3-IP is completely plug-and-play and does not 

require any software installation . The online BlueBOLT control interface is operated 
through an Internet web browser .

Note:

 Turn off all the equipment being connected to C3-IP until after all the 

connections (including AC) . It’s recommended to turn the connected equipment 
back on sequentially one unit at a time .
The total output of the 3 AC outlets shall not exceed 12A

LIGHTS

MOUNTING

Use four #10 size screws to mount the C3-IP 
to a wall or within a structured wiring can .

A. 

Using any Internet connected computer go to 

www .mybluebolt .com

 using a 

standard Internet browser .

B. 

Follow the on-screen prompts to add a 

Location

, and then to add a 

Device

 .  

Note:

 MAC address information is attached to this Instruction Manual as well as 

on the bottom of the C3-IP . It is recommended the spare MAC address label be 
adhered to the unit or stored in a secure location .

C. 

Once you input the MAC address and included Challenge Key, if BlueBOLT 
cannot detect your device (please allow up to 20 seconds), please follow the 
on-screen troubleshooting guide . Also confirm the C3-IP is properly connected 
to your networking equipment .

BLUEBOLT

The enclosure includes screw-holes to install, as well as mounting brackets (0 .125 
inch powder-coated steel) that secure the unit to the vertical posts of a standard 
equipment rack . The brackets are able to be attached to the enclosure in multiple 
directions in order to accommodate many different racks and positions .

7.35”

5.5”

7.35”

5.5”

Plan for and allow space for cords, plugs, wall-warts and transformers.

With the provided power cord, the C3-IP should 
be installed within close proximity to a main 
socket outlet .

0 .5m IEC power cord

1.75”

OUTLET

2

OUTLET

3

GROUND

Summary of Contents for BlueBOLT C3-IP

Page 1: ...www panamax com C3 IP Compact IP Power Management C3 IP A BlueBOLT Enabled Compact Power Manager with 3 Outlets Quick Start Guide ...

Page 2: ... requirements 7 Troubleshooting 8 General Use 8 BlueBOLT Network connectivity 8 C3 IP Specifications 9 Technologies 10 Protect or Disconnect 10 Standard Level RFI EMI Filtration 10 Over Under voltage load disconnect 10 Power Sequencing 10 IP Monitor and Control 10 Warranty information 11 Caution Warranty Limitation for Internet Purchasers 11 Limited three Year Warranty 11 What is Covered 11 Limita...

Page 3: ...RNING Do not use this apparatus near water To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture 6 CAUTION Could Contain Always On Receptacles depending on BlueBOLT programming To reduce risk of shock Disconnect C3 IP from power source before servicing any equipment connected to C3 IP 7 Clean only with dry cloth 8 Do not install near any heat sources such as...

Page 4: ...the connected equipment back on sequentially one unit at a time The total output of the 3 AC outlets shall not exceed 12A LIGHTS MOUNTING Use four 10 size screws to mount the C3 IP to a wall or within a structured wiring can A Using any Internet connected computer go to www mybluebolt com using a standard Internet browser B Follow the on screen prompts to add a Location and then to add a Device No...

Page 5: ...ax signal line protection modules grounds to this terminal Protect data lines as well as AC lines from surges is required for the connected equipment warranty Network Connector Connect an Ethernet cable not provided between the NETWORK port and an Internet router or modem with an established Internet connection for remote control and monitoring Outlet 3 Outlet 2 Network Reset Button Press using a ...

Page 6: ...reaker is opened or closed and if the Voltage Monitoring is working Power Condition States Normal Input voltage is within range Undervoltage The voltage is so low that the over under voltage load disconnect has engaged and all outlets are off Overvoltage The voltage is so high that the over under voltage load disconnect has engaged and all outlets are off Recovery Recovery 1 Recovering from an ove...

Page 7: ...create a unique user name and password Input a user name and password and click the Update Login button Password requirements 1 Minimum of 4 characters maximum of 32 characters 2 Case sensitive 3 Comprised of printable characters 4 The word password upper or lower case is not a valid password 5 Passwords of five characters or less may not entirely consist of repetitive characters For example 1111 ...

Page 8: ... securely installed BlueBOLT Network connectivity Check these steps when having issues with BlueBOLT connectivity Is the C3 IP receiving power Check the power cable and confirm the unit is ON Is the BlueBOLT port on the C3 IP connected to an active local area network with Internet connectivity Check the cables connecting C3 IP to the router switch cables between the router switch and modem and the...

Page 9: ...rating Control Type 1 Total Current Capacity 12A Maximum Rated Impulse Voltage 1500V Voltage Protection Rating UL1449 L N 500V Initial Clamping Level 200V Peak 141 RMS Energy Dissipation 1680 Joules Peak Impulse Current 12 000 Protect or Disconnect Yes Over voltage load disconnect 140 Vac Under voltage load disconnect 90 Vac Filtration Technology Standard RFI EMI Filtration Filtration Rating 10dB ...

Page 10: ... video systems will require power sequencing The C3 IP by default is a power sequencer Power sequencing allows A V equipment to be powered up in stages which gives equipment time to stabilize before the next stage of equipment is energized When powering down the sequence order is reversed which results in a soft landing for your expensive A V equipment Power sequencing is also convenient for netwo...

Page 11: ...TING FROM THE BREACH OF ANY WRITTEN OR IMPLIED WARRANTY Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other legal rights which vary from State to State How do I Obtain Warranty Service Customers in the United States To obtain wa...

Page 12: ...have a Return Authorization RA number To get an RA number please call Panamax Tech Support Before returning any equipment for repair please be sure that it is adequately packed and cushioned against damage in shipment and that it is insured We suggest that you save the original packaging and use it to ship the product for servicing Also please enclose a note giving your name address and phone numb...

Reviews: