     It is also important to clean the smoke outlet tubing periodically and 
check there are no blockages before relighting fuel after a long period 
of non-use. At the start of each season a professional should carry out a 
revision of the installation. 
 
     Any replacement part which  you may need must  be recommended 
by us. 
 
Commissioning and handover 
 
     Ensure all parts are fitted in accordance with the instructions. 
 
     On completion of the installation allow a suitable period of time for 
any fire cement and mortar to dry out,  before lighting the stove.  Once 
the stove is under fire check all seals for soundness and  check that the 
flue  is  functioning  correctly  and  that  all  products  of  combustion  are 
vented safely to atmosphere via the chimney terminal. 
 
     On completion of the installation and commissioning ensure that the 
operating instructions for the stove are left with the customer. Ensure to 
advise the customer on the correct use of the appliance and warn them 
to use only the recommended fuel for the stove. 
 
     Advise the user what to do should smoke or fumes be emitted from 
the  stove.  The  customer  should  be  warned  to  use  a  fireguard  to  BS 
8423:2002  (Replaces  BS  6539)  in  the  presence  of  children,  aged 
and/or infirm persons. 
 
 
 
 
 

  

10

Summary of Contents for SIERRA

Page 1: ...WOOD BURNING STOVE USAGE AND MAINTENANCE INSTRUCTIONS...

Page 2: ...of wood is no greater than that given off by its natural decomposition This means we have a source of energy that respects the natural cycle of millions of years Burning wood does not increase the CO...

Page 3: ...need slight modification to suit particular local site conditions In all cases the installation must comply with current Building Regulations Local Authority Byelaws and other specifications or regula...

Page 4: ...a possibility of disturbing any asbestos in the course of installation then please seek specialist guidance and use appropriate protective equipment Metal Parts When installing or servicing this stov...

Page 5: ...e stove to the top of the chimney should be satisfactory Alternatively the calculation procedure given in EN 13384 1 may be used as the basis for deciding whether a particular chimney design will prov...

Page 6: ...exceed 45 90 bends should not be used Combustible material should not be located where the heat dissipating through the walls of fireplaces or flues could ignite it Therefore when installing the stov...

Page 7: ...e the first tube in the smoke outlet circle at the top of the stove and attach the other tube onto the end 2 Join it to be rest of the chimney 3 If the tubing reaches the exterior of your home place t...

Page 8: ...the stove as certain components of the heat resistant paint burn while the pigment of the actual stove is fixed Therefore the room should be aired until the smoke disappears The woodstove is not desi...

Page 9: ...lear out ash Empty it regularly without waiting for it to fill up too much to avoid the grill becoming damaged Take care with the ash which may still be hot up to 24 hours after the stove has been use...

Page 10: ...ortar to dry out before lighting the stove Once the stove is under fire check all seals for soundness and check that the flue is functioning correctly and that all products of combustion are vented sa...

Page 11: ...been identified and corrected If necessary seek expert advice The most common cause of fume emission is flueway or chimney blockage For your own safety these must be kept clean at all times IMPORTANT...

Page 12: ...left from the open fire usage have not been loosened by the higher flue temperatures generated by the closed stove In situations where it is not possible to sweep through the stove the installer will...

Page 13: ...ade should be called immediately Do not relight the stove until the chimney and flueways have been cleaned and examined by a professional Permanent air vent The stove requires a permanent and adequate...

Page 14: ...unable to solve the problem they will contact us and send us the stove if necessary Our company will replace any faulty parts free of charge up to two years from the date of purchase We will not char...

Page 15: ...flue draught for nominal heat output 11 9 Pa Flue gas mass flow 9 7 g s Flue gas temperature 285 C Distance to adjacent combustible materials 50 cm Heating volume aprox 250 m3 Thermal output 8 9 kW E...