24
SECURITY NORMS FOR GAS OUTPUT AND AIR INPUT.
4.9.
Gas output must be located in a ventilated area, not in closed or half-closed areas e.g. garage, corridor, air
space of the house or places where gas may concentrate.
4.10.
The external parts of the stove may reach high temperatures that might burn when touching; it is
recommended to use a non flammable grid to avoid risk of burn for children and old people.
The end of the gas outlet flex should remain higher than the stove’s output.
It is mandatory to install at least
two metres in length vertically
to create natural current preventing smoke, odors or eventual cut of electric
supply.
The horizontal pipe must not be longer than 1
metre
;
greater lengths mean ash, condensation or corrosion
may build up in this area.
Faced with cut of electric supplies and unusual weather conditions (storms, strong winds) it is
recommendable to install an uninterruptible power supply (UPS) which we have available as an option. This
only supplies the exhaust blower.
4.11.
Distances from doors, windows, ventilation grids or air input to the house or building:
Drawing 2
4.12.
The minimum distance from gas outlet to ground shall be minimum 65cm, depending however on the
surface. Gas may burn grass, plants, trees located near the gas outlet. In the event that the stove outlet is
lower, suitable safety measures should be taken. The outlet pipe should never be below the extractor itself.
4.13.
The distance between gas outlet and public pavement shall be minimum 2.20 m. See your local regulations.
4.14.
Never
fix the gas outlet flex in a chimney or a flex already installed which diameter is 4 times as large as the
stove’s flex (Ø80 max. 200 cm
2
). When installing the stove in higher section the gas outlet must be channeled
to the top.
If the tube that was installed previously was used with another type of heating (wood, oil, etc.), you
MUST
clean it thoroughly.
4.15.
Gas outlet flex cannot be installed in a share pipe such as the pipe of an extractor hood, another stove or
heating system.
4.16.
If gas outlet installation is wrong, combustion air’s homogeneity might be bad which could make the wall of
the house or the building dirty, aggregate trash inside the stove and thus be the source of premature
degradation of the spare parts and gas outlet pipe.
4.17.
The air input pipe should not be drained with the risk of affecting the correct operation of the stove. For this
reason, and in order to facilitate fresh air input, it is necessary to set up a ventilation grid
AT NOT LESS
than
50cm both horizontally and vertically from gas output,
see point
4.11.
Direct air currents shall also be avoided as they might prevent a correct operation of the stove and as a
consequence, heat performance.
4.18.
In any case the design of the chimney termination will impede the free diffusion in the atmosphere of
combustion products. A metallic mesh with a gap of 3x3 cm can be placed to avoid the entry of birds or
unwanted objects.
COMPLIANCE WITH THESE NORMS ARE OUT OF PANADERO CONTROL; PANADERO DOES NOT BEAR THE
RESPONSIBILITY FOR ANY RESULTING DAMAGE.
WE RECOMMEND THAT A CONFIRMED SPECIALIST SETS UP YOUR PELLETS STOVE.
A
Distance from ventilation grid.
500 mm
B
Distance from ventilation grid.
500 mm
C
Lateral side of a window.
1250 mm
D
Top of a window.
650 mm
E
Top of a door.
650 mm
F
Lateral side of a door.
1250 mm
G
Adjacent wall.
300 mm
H
Height from adjacent wall.
2300 mm
I
Adjacent building.
650 mm