10.2. Connection – audio and control data

Pan Net

Interface

USB

Audio

Lan

Analogue / AES3

Pan Net

Dante

Pan Net

High-quality cables must be used for safe and reliable signal cabling. At least CAT6 S/STP or CAT6 F/

STP network cables must be used for the Pan Net cabling.  At least CAT6 network cables with appropriate 

shielding must also be used for the cabling of IP networks. For more information on Pan Net, see the Pan 

Net manual.

Summary of Contents for P SW-118 SP

Page 1: ...oustics reserves the right to modify products without prior notice All products are designed developed and manufactured by Pan Acoustics in Germany Doc No 2021_01332 DOCUMENTATION B E A M SPEAKER SUBWOOFER 2 LINE MANUAL P SW 118 SP VARIANTS ANALOGUE AES D Read the manual carefully before putting the device into operation The manual must be retained V 1 0 Shapely Versatile Functional ...

Page 2: ...work This document must be kept with the product or in a safe place so that it is available when needed If the product is resold the document must be handed over to the new owner in printed or electronic form Pan Acoustics reserves the right to change update the document without prior notice The latest version of this document can be downloaded from the Pan Acoustics website Pan Acoustics GmbH Sch...

Page 3: ...1 Mains power connection 11 10 2 Connection audio and control data 12 10 3 Connection additional passive subwoofer system 13 11 Error description 14 12 Service and repair 15 13 Maintenance measures 15 14 EC conformity CE Mark 15 15 WEEE declaration disposal 15 16 Contact address 15 17 Appendix 16 17 1 Pan Net RJ45 pin assignment 16 17 2 Alarm contact alarm loop 16 17 3 Control via media controller...

Page 4: ...dling of the product Failure to observe this instruction may result in damage to the product or malfunctions 2 Symbols and explanation This symbol indicates a hazard with a high level of risk If this hazard is not avoided serious injury or death may result This symbol indicates a hazard with a medium level of risk If this hazard is not avoided moderate to serious injury or death may result This sy...

Page 5: ... or humidity Exception versions with an appropriate IP protection class no objects filled with liquid e g bottles must be placed on top of the device ventilation slots must not be covered up with objects e g textiles the device must not be exposed to excessive heat direct sunlight fire or the like no open fire sources e g candles must be placed on top of the device To prevent injury this product m...

Page 6: ...he transport company and the shipper must be notified without delay Safety may be compromised if the product shows signs of visible damage no longer works correctly has been stored for a long time under unfavourable conditions has been transported incorrectly e g unsuitable packaging If the product shows signs of impairments that no longer guarantee safe operation the device must be secured and la...

Page 7: ...rom Pan Acoustics may be used Pan Subwoofer Product series for active and passive subwoofer systems Pan Net Audio signals control signals and monitoring of active Pan Acoustics loudspeakers Pan Beam Setup software Software for setting up active Pan Acoustics loudspeakers RJ45 etherCON Plug connection for the transmission of signals powerCON TRUE1 Power connection for devices that can be plugged an...

Page 8: ...one after the other General Purpose Interface GPI Describes a platform independent connection between devices from different manufacturers 9 1 P SW 118 SP connector panel and variants 9 1 1 P SW 118 SP and P SW 118 SP AES connector panel No Description 1 Clip LED Display for input overload 2 Status LED Display for operating status 3 Pan Net IN THRU Input output for audio signals ana logue and AES3...

Page 9: ... audio output AES3 control signals and relay contact GPI 5 Ext subwoofer output Connection for passive P SW 118 6 powerCON TRUE1 In Out Mains power connection 3 1 2 5 6 4 To avoid malfunctions the recommended bending radius of the mains power and signal connection cables must be observed The warnings on the connector panel must be observed 9 2 Mounting plate and stacking recesses No Description 1 ...

Page 10: ...over The spacer bar article no 802455 must not be used in the extracted position If several devices are stacked on top of each other it must be ensured that the devices sit securely in the stacking recesses The stacked devices must be protected by suitable means against live loads The P SW 118 SP variants can be combined with a PB 08 from the Pan Beam series to a loud speaker system The following ...

Page 11: ...needed it is strongly recommended to operate only one device per mains phase Only operate the device on mains power supplies with earth contact Damaged mains power cables or plugs must be replaced with a faultless mains power cable or plug It must be ensured that the mains power plug is always freely accessible to be able to disconnect the device from the mains power supply in case of danger or ma...

Page 12: ...n Net Dante Pan Net High quality cables must be used for safe and reliable signal cabling At least CAT6 S STP or CAT6 F STP network cables must be used for the Pan Net cabling At least CAT6 network cables with appropriate shielding must also be used for the cabling of IP networks For more information on Pan Net see the Pan Net manual ...

Page 13: ...Manual 10 3 Connection additional passive subwoofer system The active P SW 118 SP subwoofer system can drive one passive P SW 118 An NL4 loudspeaker cable must be used for the connection between the active subwoofer and the passive sub woofer ...

Page 14: ...ted Connect audio signal via audio input on the interface crosspoint not set in Dante controller routing matrix No audio playback despite connection Wrong audio input chosen Check audio connection for correct connection No audio playback despite correct connection No audio signal cable defective Check audio signal check cable to the source Dante Distorted audio playback Incorrect sample rate or li...

Page 15: ...nnections and mains power connection for correct fit and damage Check that the grille is firmly inserted into the enclosure Check the enclosure for damage Check ventilation slots in the connector panel ventilation must not be impaired by foreign bodies If the error is not specified in the above table or cannot be remedied using the measures men tioned please consult the technical support of Pan Ac...

Page 16: ...y means of daisy chain cabling In order to close the loop for the alarm contact a jumper must be set between pin 3 and pin 6 see chapter 17 1 Pan Net RJ45 pin assignment on the device located at the end of the cabling The Pan Net jumper plug article no 804105 can be used for this purpose Via the Pan Con and Pan Splitter interfaces the alarm loop can be evaluated via all connected devices of a Pan ...

Page 17: ...cted loudspeakers Reactivation is only possible via technical support Parallel operation of a media controller and the Pan Beam Setup program is not possible and must be avoided Control commands Calling up presets String HEX Preset 1 0x02 0x46 0x46 0x46 0x45 0x52 0x1C 0x30 0x31 0x1C 0x30 0x32 0x30 0x32 0x0D Preset 2 0x02 0x46 0x46 0x46 0x45 0x52 0x1C 0x30 0x32 0x1C 0x30 0x32 0x30 0x33 0x0D Preset ...

Page 18: ...cs loudspeaker appears in the Dante network under the Dante Receivers tab The loudspeaker has two inputs Input A and Input B For audio routing the relevant connection must be set between the desired Dante transmitter and the Pan Beam loudspeaker The relevant audio source Input A and or Input B must also be activated in the loudspeaker via the Pan Beam Setup software 17 4 3 Device configuration Vari...

Page 19: ...ted to the secondary port and operated in the Dante network Connecting another Dante capable device to the secondary port in the switched mode is technically possible but not recommended Redundant If the Dante interface is set to redundant the Pan Beam loudspeaker can be connected to the redundant Dante network with a second network cable 17 4 5 Status Via the Status tab information on the device ...

Page 20: ...fer series attention must be paid to the correct connection sequence input output If both audio channels A B are needed on the connected AES EBU loudspeakers the corresponding cross point must be set in the Dante controller 1 17 4 7 Dante LED status indicator Above the etherCON ports for the Dante or AES67 net work there are two LEDs for status indication The LINK ACT LED is green if everything is...

Page 21: ... commands Network address and port Address 224 0 1 4 Port 4712 17 4 9 Dante media controller Pan Beam Alarm USB PWR Pan Con 485 TRX Each Pan Beam loudspeaker has an alarm contact The loudspeaker can indicate a detected error via this alarm contact For this purpose a switch relay is installed in the loudspeaker which is closed in normal operating status If the loudspeaker is not in operation if the...

Page 22: ...TACT Pan Acoustics GmbH Schweigerstr 13d D 38302 Wolfenbüttel Germany Tel 49 0 5331 900 95 70 Fax 49 0 5331 900 95 79 E mail contact pan acoustics de www pan acoustics de QUALITY MADE IN GERMANY SINCE 2002 ...

Reviews: