Pan Acoustics Mundorf AMT P 02 Manual Download Page 13

© Pan Acoustics GmbH   

 V 1.0    

Page 13 of 18     

Manual 

                                                                                                

The product is suitable for operation in an ambient temperature from -10 °C to +50 °C. If the prod-

uct is operated below 0 °C, the device must be operated by means of a continuous signal in order to 

prevent the loudspeaker chassis from freezing.

Before operating the device for the fi rst time, it must be acclimatised. Avoid exposing the device to 

aggressive chemical liquids and vapours. The device must not be covered up by textiles. Take pre-

cautions to prevent the enclosure from heating up due to direct exposure to sunlight or powerful 

spotlights. The device must also not be exposed to strong vibrations.

8.4. 

Operation on the power amplifi er

9. Operating conditions

Service and repair work may only be carried out by persons and partners authorised by Pan Acoustics. 

No service or repair measures are to performed on the device that exceed the statements made in 

chapter 11 “Maintenance”.

Contact data:

--> see chapter 15 “Contact address”.

The following measures must be carried out at regular intervals:

Cleaning

The enclosure should be regularly dusted off  with a damp cloth and checked for damage.

Visual and functional check

The installed device should be regularly subjected to a visual check. 

The following checks must be carried out:

• 

Check the wall and ceiling mount for a fi rm fi t.

• 

Check the enclosure for damage.

• 

Check the connection cable for damage.

10. Service and repair

11. Maintenance measures

The declaration of conformity for the relevant product from the Pan AMT series can be requested from 

Pan Acoustics.

12. Declaration of conformity

The waste bin symbol indicates that electrical and electronic devices must not be dis-

posed of with household waste after their useful life. This symbol can be found on the 

type plate of our products. Dispose of the device in accordance with the applicable regu-

lations and any contractual agreements. If you have any questions about disposal, please 

contact your dealer, distributor or us.

13. WEEE declaration (disposal)

The loudspeaker P 04-AMT | RJ must be operated on a correctly confi gured DSP amplifi er or amplifi er 

with upstream audio DSP. The power of the amplifi er to be used must be limited to 20 watts (pro-

gramme) and 60 watts (peak). Further technical descriptions of the loudspeaker can be found in the 

technical data --> see chapter 17 ”Technical data loudspeaker”.

DSP settings for various DSP amplifi ers and DSP audio platforms for sound equalisation can be down-

loaded from the Pan Acoustics website www.pan-acoustics.de. If you have any technical questions, 

you can also contact our support team at [email protected].

The RJ plug connections on the power amplifi er or on the loudspeaker must not be plugged 

or unplugged under load. Plugging or unplugging the RJ plugs under load will cause elec-

trical damage to the contacts in the socket or on the plug.

WARNING

Summary of Contents for Mundorf AMT P 02

Page 1: ...an Acoustics reserves the right to modify products without prior notice All products are designed developed and manufactured by Pan Acoustics in Germany Doc No 2022_01503 DOCUMENTATION SPEAKER B E A M 2 LINE A M T MANUAL PAN AMT P 04 AMT RJ VARIANTS Read the manual carefully before putting the device into operation The manual must be retained V 1 0 Shapely Versatile Functional ...

Page 2: ...r in a safe place so that it is available when needed If the product is resold the document must be handed over to the new owner in printed or electronic form Pan Acoustics reserves the right to change update the document without prior notice The latest version of this document can be downloaded from the Pan Acoustics website Pan Acoustics GmbH Schweigerstr 13d 38302 Wolfenbüttel Tel 49 0 5331 900...

Page 3: ...10 8 2 Electrical connection 10 8 2 1 P 04 AMT RJ low impedance 10 8 3 Important notice regarding the network cable and amplifier power 12 8 3 1 Permissible cable cross sections and lengths 12 8 3 2 RJ pin assignment 12 8 3 3 RJ adapter 12 8 4 Operation on the power amplifier 13 9 Operating conditions 13 10 Service and repair 13 11 Maintenance measures 13 12 Declaration of conformity 13 13 WEEE de...

Page 4: ...product properties available at the time of preparation and the safety regulations applicable at that time This operating manual describes the setup function and connection of the Pan AMT loudspeaker sys tems P 04 AMT RJ and P 04 AMT RJ mB It is aimed at system technicians and persons assigned the task of installing and operating a relevant system Pan Acoustics reserves the right to make changes a...

Page 5: ...arly marked and secured against accidental operation if the product shows signs of visible damage contains loose parts no longer works flawlessly has been stored for a long time under unfavourable conditions e g in humid rooms was exposed to severe transport stress e g with unsuitable packaging To avoid injuries such as hearing damage due to excessive volume levels persons should never stand direct...

Page 6: ...ured and labelled accordingly It must also be ensured that no intentional or accidental opera tion by third parties is possible The loudspeaker is suitable for indoor operation In outdoor areas the loudspeaker must only be oper ated with a suitable IP protection class IP54 or IP65 Sufficient air circulation must be ensured when operating the device indoors The device may be damaged by condensation I...

Page 7: ...oned according to the acting forces that may occur through lever effects In case of doubt as to the type and composition of the building structure consult a structural engineer CONNECTION OF THE LOUDSPEAKER AND MOUNT All mounts sourced via Pan Acoustics for the Pan AMT series are delivered with suitable installation material for connection with the loudspeaker The connection between the loudspeaker...

Page 8: ...cket The bracket features three fixing points for mounting e g on a building surface To mount the U bracket on a surface it must first be removed from the loudspeaker After mounting the bracket on the wall the loudspeaker must be inserted into the bracket and fixed see step 3 Tools required for assembly disassembly of the U bracket Hexagon screwdriver Step 1 Unscrew 2 x hexagon screw ...

Page 9: ...9 of 18 Manual Step 3 Secure plastic washer Mount the bracket on the desired building sur face When assembling position the plastic washers appropriately Assembly is done in reverse order NOTICE Step 2 Pull off the bracket to the back ...

Page 10: ... 24 AWG network cables Alternatively an adapter cable is available to operate the loudspeaker with DSP power amplifiers that do not have an RJ45 compatible port The U bracket can be swivelled from the centre to the left and right by 110 each To adjust the set angle hand tighten the screws connecting the U bracket to the lids 8 1 2 Angle of the U bracket 8 2 Electrical connection 8 2 1 P 04 AMT RJ ...

Page 11: ...nnect the network cable to the socket of the loudspeaker and snap it into place Step 2 Run the network cable with the RJ45 plug to the loudspeaker Check the locking mechanism of the connection cable for function to prevent the cable from slipping out NOTICE ...

Page 12: ...erably depending on the cable cross section To prevent a cable fire the cross section of the cable must be sufficiently dimensioned WARNING 1 8 CAT5e or CAT6 cables are suitable for adapted power transmission if their cross sections correspond to 23 AWG or 24 AWG cables Shielded cables are NOT required For optimum power transmission only use cables with copper cores NOTICE 8 3 3 RJ adapter CAT cable...

Page 13: ...ck the enclosure for damage Check the connection cable for damage 10 Service and repair 11 Maintenance measures The declaration of conformity for the relevant product from the Pan AMT series can be requested from Pan Acoustics 12 Declaration of conformity The waste bin symbol indicates that electrical and electronic devices must not be dis posed of with household waste after their useful life This...

Page 14: ...es IP54 and IP65 For further information on the warranty please refer to the Pan Acoustics warranty conditions https www pan acoustics de en service warranty 16 Mounts Recommended mounts for mounting products from the Pan AMT series on walls and ceilings or for mobile use include Tripod mount Wall mount TWM II Wall ceiling mount P PB 04 with access protection Stand for P PB xx loudspeaker systems ...

Page 15: ...er at least 600 W 4 ohms per channel Sensitivity 93 dB 1 W 1 m Maximum SPL 126 dB 1 m Impedance 4 ohms Horizontal radiation pattern 130 Vertical radiation pattern 20 Connections 1 x RJ45 Temperature range 10 C to 50 C ambient temperature MECHANICAL PROPERTIES Enclosure Aluminium profile Grille Powder coated perforated metal sheet Standard colours with silver lids optional lids in enclosure colour ...

Page 16: ... Pan Acoustics GmbH V 1 0 Page 16 of 18 Manual 18 Technical drawing loudspeaker 18 1 P 04 AMT RJ 506 mm 107 mm 116 mm ...

Page 17: ... Pan Acoustics GmbH V 1 0 Page 17 of 18 Manual 18 2 P 04 AMT RJ mB 522 mm 137 mm 152 mm 107 mm ...

Page 18: ...TACT Pan Acoustics GmbH Schweigerstr 13d D 38302 Wolfenbüttel Germany Tel 49 0 5331 900 95 70 Fax 49 0 5331 900 95 79 E mail contact pan acoustics de www pan acoustics de QUALITY MADE IN GERMANY SINCE 2002 ...

Reviews: