Palstar PM5K Owner'S Manual Download Page 4

 

PM5K  WATTMETER     

1-800-773-7931    WWW.PALSTAR.COM 

Introduction 

 
Thank you very much for purchasing the Palstar PM5K Series RF 
Power/VSWR  Indicator.  The  PM5K  represents  a  breakthrough in 
features for measurement of the performance of your transmitting 
system.  Microprocessor  control  insures  fast  capture time  and low 
power  consumption.  With  the  ability  to  monitor  your  VSWR  and 
power levels  at  all  times,  you  will  know  that  your  transmitter,  RF 
source, and load, or antenna systems are operating effectively and 
safely.  In addition, the power and VSWR relay alarms can quickly 
shut down your power amplifier system and alert you to the alarm 
condition.  This  places  an  additional  layer  of  protection  in  your 
transmitting  system  to  help  preserve  expensive  tubes  and  fi-
nals.  The PM5K also features the ability to be monitored and con-
trolled from  a PC via the bundled software, and the unique ability 
to  be  monitored  and  controlled  over  a  LAN  or  from  the  internet. 
PM5K firmware updates will be made available for download from 
the Palstar website as they become available. This means that the 
user can take full advantage of features or enhancements just by 
installing the firmware update. No need to return the meter to the 
factory for updates. 
 
There  are  many  features  introduced  in  the  PM5K  that  have  not 
been seen before! We are very proud of our product and are inter-
ested in learning about your experiences with this meter.  We also 
want to  know  if  you have ideas  about new  features  we can bring 
forth for the meter. We have built in the ability to enhance the me-
ter with software updates that you can download from the internet.  
We think you will agree that this is a totally new concept in an RF 
Wattmeter, and one that should extend its lifetime for a long time 
to come. 

 

We want you to be satisfied with your purchase.  If you have any 
type of problem, please check the Trouble Shooting section of this 
manual.    If  your problem  persists,  call  our Customer  Service De-
partment  at  1-800-773-7931.  Updates  are  available  for  download 
from  the  Palstar  website  as  they  become  available.  This  means 
that the user can take full advantage of features or enhancements 
just by installing the firmware update. No need to return the meter 
to the factory for updates.  
 

 

PM5K  WATTMETER     

1-800-773-7931    WWW.PALSTAR.COM 

 

1.5 

– 30MHz, 50-54 Mhz

 

50 ohms nominal, <1.05 V.S.W.R. insertion

 

.05 dB or less

 

SO-239 female (Type-N, and 7/16 DIN optional)

 

1 to 3,005 watts   (3KW HF)

 

1  to  9,999  watts  (10  KW  HF)    -  Limited  by 
VSWR to the limits of the connector

 

1.00 to 99.00

 

< ±5% as measured against NIST traceable cali-
brated  instruments  (see  accuracy  section  on 
how to achieve better accuracy)

 

10  Bit  A/D 

–  4  overlapping  channels  of  auto 

ranging = 12 Bit effective resolution

 

< 10 milliseconds

 

< 45 milliseconds

 

> 30Hz

 

Off,  1.5,  2.0,  2.5,  3.0 

–  relay  programmable  to 

open or close on trip

 

Off, 5, 50,  100,  250, 500, 1,000, 2,000  watts    - 
NC and NO relay contacts are available

 

Off, 175, 225, 700, 1,100, 1,600, 2,600, 3,000

 

.5 Ampere 50 volts AC/DC

 

Manual front panel (stand alone) or via RS232 

– 

application software

 

12 - 15V DC at 600 ma

 

-35C to +25C

 

Exceeds  FCC  Class  B  (tested)  and  CE    -  both 
emissive  and  conductive  (tested)  as  well  as 
EMP 4 KV and 8 KV on cables

 

Display 8 ¼

” X 3 ½ “Face, 4 ¼” Deep

 

Coupler 2 ¾

” X 2 ¾” X 6 ½”

 

5 lbs (2.3 kg)

 

Summary of Contents for PM5K

Page 1: ...ed 9676 N Looney Rd Piqua OH 45356 USA Customer Service and Sales Telephone 1 800 773 7931 Fax 1 937 773 8003 Email info palstar com Copyright 2007 Palstar Inc Printed in the U S A PM5K DigitalWattmet...

Page 2: ...4 Quick Setup 6 Installation 7 General Operation 8 Using the PM5K Front Panel 9 Rear Panel Connections 16 Remote Coupler Mounting 16 Directional Coupler Mounting 17 Accuracy and Calibration 17 In Cas...

Page 3: ...damaged in shipment Our service rate is 30 per hour 1 2 hr mini mum Return Policy All returns must receive prior au thorization from Palstar Returned items must be received in original AS SHIPPED con...

Page 4: ...e have built in the ability to enhance the me ter with software updates that you can download from the internet We think you will agree that this is a totally new concept in an RF Wattmeter and one th...

Page 5: ...esting and Certification Dimensions Shipping Weight PM5K WATTMETER 5 1 800 773 7931 WWW PALSTAR COM Write your new PM5K serial number and calibration data for your coupler here see coupler sticker Ser...

Page 6: ...it off The in ternal tuner will cause a 50 ohm impedance to be presented to the finals of your transmitter thereby changing the characteristic im pedance present at the antenna jack on the transmitter...

Page 7: ...ILS DISPLAY HEAD AND COUPLER LOCATION The Display Enclosure is designed to be either table top or 19 inch rack mounted with the optional rack mounting plates You can mount one or two meters side by si...

Page 8: ...that can affect your audio CW tone modulation and also your PC The PM5K eliminates this possible source of RFI since the signals passed to its display head are merely DC voltages from the re mote coup...

Page 9: ...ow you program it these are 5 amp 50V contacts Tip normally open Ring normally closed Sleeve common DC 12 15V 2 1 mm coaxial DC power jack used to supply meter with DC power center pin is V PTT IN and...

Page 10: ...ALSTAR COM Other useful aspects of the meter VSWR is not displayed if the forward power is less than 5 watts VSWR alarm function is disabled if the forward power is less than 10 watts in normal modes...

Page 11: ...600 19 200 38 400 Pushing the menu button returns unit to normal operation mode PM5K WATTMETER 11 1 800 773 7931 WWW PALSTAR COM Low Power Alarm Menu Push the mode select button to choose trip point...

Page 12: ...d into the meter via the software application program You must use the software to program the call text Pushing the menu button again takes us to the next menu item PM5K WATTMETER 13 1 800 773 7931 W...

Reviews: