40 

WATER SUPPLIES 

 

This  water  heater  must  be  installed  in  accordance  with  this  advice  to  be  covered  by  the  Paloma 
warranty. 

 
This  water  heater  is  manufactured  to  suit  the  water  conditions  of  most  public  reticulated  water 
supplies. However, there are some known water chemistries which can have detrimental effects on 
the  water  heater  and  its  operation  and / or  life  expectancy.  If  you  are  unsure  of  your  water 
chemistry, you may be able to obtain information from your local water supply authority. This water 
heater  should  only  be  connected  to  a  water  supply  which  complies  with  these  guidelines  for  the 
Paloma warranty to apply. 
 

CHANGE OF WATER SUPPLY 

The  changing  or  alternating  from  one  water  supply  to  another  can  have  a  detrimental  effect  on 
the operation and / or life expectation of a heat exchanger in a continuous flow water heater. 
 
Where there is a changeover from one water supply to another, e.g. a rainwater tank supply, bore 
water  supply,  desalinated  water  supply,  public  reticulated  water  supply  or  water  brought  in  from 
another supply, then water chemistry information should be sought from the supplier or it should be 
tested to ensure the water supply meets the requirements given in these guidelines for the Paloma 
warranty to apply. 
 

SATURATION INDEX 

The saturation index (SI) is used as a measure of the water’s corrosive or scaling properties. 
 
In a corrosive water supply, the water can attack copper parts and cause them to fail. Where the 
saturation  index  is  less  than  –1.0,  the  water  is  very  corrosive  and  the  Paloma  warranty  does  not 
apply to a copper heat exchanger in a continuous flow water heater. 
 
In  a  scaling  water  supply  calcium  carbonate  is  deposited  out  of  the  water  onto  any  hot  metallic 
surface.  Where  the  saturation  index  exceeds  +0.80,  the  Paloma  warranty  does  not  apply  to  a 
copper heat exchanger in a continuous flow water heater. 
 
Water  which  is  scaling  may  be  treated  with  a  water  softening  device  to  reduce  the  saturation 
index of the water. 
 
Refer to the Saturation Index chart on page 41. 
 
 

Summary of Contents for PH-246CWHA

Page 1: ......

Page 2: ...ll this water heater and ask for your Compliance Certificate Warning Upon completion of the installation and commissioning of the water heater leave this guide with the householder or a responsible of...

Page 3: ...ry care has been taken to ensure accuracy in preparation of this publication No liability can be accepted for any consequences which may arise as a result of its application CONTENTS HOUSEHOLDER We re...

Page 4: ...PERATION The water heater operates automatically heating water as it passes through the water heater When a hot tap is opened the gas burners ignite to provide immediate heating of the water The heat...

Page 5: ...the means to inhibit the growth of Legionella bacteria in potable water When this water heater is used as an in series booster for a solar water heater it can satisfy this AS 3498 requirement provide...

Page 6: ...touch the power plug with wet hands SAFETY This water heater is supplied with temperature sensors a FlameSafe protection system and a pressure relief valve These devices must not be tampered with or...

Page 7: ...mended minor maintenance be performed every six months by the dwelling occupant The minor maintenance includes Inspect around the air inlet flue terminal and the water heater in general for plant grow...

Page 8: ...is on will go out Switch off the electrical supply at the power outlet to the water heater if there is no risk of freezing conditions occurring refer to note below Close the gas isolation valve at the...

Page 9: ...page 78 If it is necessary to switch the power off to the water heater and there is a risk of freezing then it is necessary to drain the water heater refer to Draining the Water Heater on page 8 Pipe...

Page 10: ...e pipe work between the solar storage tank if one is installed and the in series gas booster has a minimum recommended pipe size of DN20 MUST BE of copper and be fully insulated in accordance with the...

Page 11: ...esigned to allow the water heater to deliver a selected volume of water at a selected temperature Bath filling takes place when the hot tap is opened When the set volume has been delivered the water f...

Page 12: ...r they are on or off when hot water is flowing regardless of which controller has priority display panel The current temperature setting is displayed on all controllers whether hot water is flowing or...

Page 13: ...on off button to deactivate the controller on off light is off Press and hold the up button Press the on off button whilst the up button is pressed The sound for the controller is deactivated Repeat...

Page 14: ...efaults to the pre set outlet temperature setting This may be up to PH 246CWHA series 60 C Refer to How Hot Should The Water Be on page 4 On a building fitted with a temperature limiting device such a...

Page 15: ...l scroll the temperature setting up to a maximum 43 C if there is hot water flowing or 55 C if there is no hot water flowing From the 45 C setting the up button must be pressed once for each increase...

Page 16: ...ority if a Bathroom controller is on Notes on the Kitchen controller The controller cannot be turned on whilst a hot tap is open The Kitchen controller must be on and have priority in order to adjust...

Page 17: ...e Adjustment Standard Controller on page 14 The selected temperature setting will be displayed on all controllers 4 Open the hot tap The in use light will glow on all controllers 5 Close the hot tap T...

Page 18: ...re limiting device is installed in the hot pipe to the bathroom or up to 55 C if a temperature limiting device is not installed Notes on the Bathroom controllers The controller cannot be turned on whi...

Page 19: ...he Bathroom controller Press the on off button The on off operating light and the priority light will both glow The temperature setting of 40 C will be displayed 3 Select the temperature setting Press...

Page 20: ...r down button will change the water volume setting by 10 litres Pressing the up button or down button continuously will scroll the water volume setting Fifteen seconds after the water volume has been...

Page 21: ...troller on page 12 The factory pre set water volume is 180 litres If a hot tap is not opened for one hour after the new water volume has been set then the setting will be automatically cancelled The w...

Page 22: ...xe controllers whether hot water is flowing or not when any Deluxe controller is on If all Deluxe controllers are off the display remains blank up button The up button increases the water temperature...

Page 23: ...BATH FILL VOLUME up button The up button increases the bath fill water volume setting in increments of 10 litres up to 500 litres A further setting of 990 litres can be selected BATH FILL VOLUME down...

Page 24: ...rom the water heater during Bath Fill mode the bath is ready please turn off the hot water tap and press the BATH FILL button to finish When the BATH FILL button is pressed to halt the bath fill funct...

Page 25: ...utton then within four 4 seconds press the ON OFF button Each press of the ON OFF button will change the voice prompt and operating tone in the following sequence operating tone MAX voice prompt OFF o...

Page 26: ...talled the water heater defaults to the pre set outlet temperature setting This may be up to PH 246CWHA series 60 C Refer to How Hot Should The Water Be on page 4 On a building fitted with a temperatu...

Page 27: ...45 C if there is no hot water flowing From the 45 C setting the up button must be pressed once for each increase in temperature increment The temperature setting cannot be increased above 43 C whilst...

Page 28: ...e Deluxe controller cannot be turned on whilst a hot tap is open The Kitchen Deluxe controller must be on and have priority ACTIVE light glows in order to adjust the temperature setting on the Kitchen...

Page 29: ...e has been decreased Refer to Temperature Adjustment Deluxe Controllers on page 26 The selected temperature setting will be displayed on all Deluxe controllers 4 Open the hot tap The operating light w...

Page 30: ...room Deluxe controller must be on in order to adjust the temperature setting on the Bathroom Deluxe controller The Kitchen Deluxe controller can be turned off from a Bathroom Deluxe controller Press a...

Page 31: ...has been increased When the down button is pressed the voice prompt will sound hot water temperature has been decreased Refer to Temperature Adjustment Deluxe Controllers on page 26 The selected temp...

Page 32: ...rs It is advised to turn off all Deluxe controller s before activating the Bath Fill mode Refer to the notes on the Bathroom Deluxe controllers on page 29 2 Pull down the front panel on the Deluxe con...

Page 33: ...The temperature display will go blank The BATH FILL operating light will commence to flash The voice prompt will sound the bath is ready please turn off the hot water tap and press the BATH FILL butt...

Page 34: ...on is pressed and the temperature setting is decreased the voice prompt will sound hot water temperature has been decreased The selected temperature setting will be displayed in the temperature displa...

Page 35: ...t will glow on all Deluxe controllers The bath fill water volume display panel will go blank and the bath fill indicator light will go out 3 seconds after the last press of either of the volume adjust...

Page 36: ...bath fill water volume display panel will show 0 litres The temperature display will go blank The BATH FILL operating light will commence to flash The voice prompt will sound the bath is ready please...

Page 37: ...ight will flash The voice prompt will sound bath filling has been stopped please turn off the hot water tap and press the BATH FILL button to finish Close the hot tap Press the BATH FILL button again...

Page 38: ...the Bath Fill mode is turned on If the ACTIVE light is glowing on a Deluxe controller it will go out The ACTIVE light on a Deluxe controller will not glow whenever the BATH Fill operating light is on...

Page 39: ...on the bath fill operation continues until the remaining bath fill water volume is consumed then The water flow will cease and the voice prompt will sound the bath is ready please turn off the hot wa...

Page 40: ...The bath fill temperature setting will replace the temperature setting in the temperature display panel When the bath fill temperature setting is lower than the Deluxe controller temperature setting...

Page 41: ...nwater tank supply bore water supply desalinated water supply public reticulated water supply or water brought in from another supply then water chemistry information should be sought from the supplie...

Page 42: ...41...

Page 43: ...outlet switched on Is power available in the house Try using another electrical appliance Is the isolation valve in the gas line open Is there a gas supply to the rest of the house Try lighting anoth...

Page 44: ...ess of the solar collectors will be greatly reduced Have the trees trimmed or the solar collectors relocated if the obstruction is permanent or clean the collector glass Ensure the glass on your solar...

Page 45: ...ue If an error code appears Close the hot tap turn off the controller s and switch off the electrical supply to the water heater Check the gas isolation valve at the gas inlet to the water heater is f...

Page 46: ...redundancy into the hot water supply system The PH 246CWHA series water heater may be installed as an in series gas booster to a solar water heater For information relating to the function and operati...

Page 47: ...ns Standard The distances are measured along the wall behind the water heater At least 300 mm between the top of the flue terminal and the eaves At least 300 mm between the flue terminal and the edge...

Page 48: ...water heater must be insulated with suitable thickness insulation if freezing conditions are likely to occur The insulation must be fitted to the underside of the water heater and be weatherproof and...

Page 49: ...water heater the cold water line to the temperature limiting device can be branched off the cold water line either before or after the isolation valve and pressure limiting valve to the water heater...

Page 50: ...gher water temperatures generated under certain conditions in the solar collectors of an open circuit direct solar water heater an additional effective back flow prevention device also should be used...

Page 51: ...ed The circulator must not be set to operate continuously i e 24 hours per day Temperature Limiting Device A temperature limiting device cannot be installed in circulated hot water flow and return pip...

Page 52: ...The hot water line from the water heater and the pipe work between the solar storage tank if one is installed and the in series gas booster must be insulated in accordance with the requirements of AS...

Page 53: ...utlet temperature is 55 C Kitchen Controller Only Bathroom Controllers Only Note The maximum outlet temperature is 55 C in a domestic situation The maximum programmable temperature is 60 C No Controll...

Page 54: ...in 24 Mass Empty unpackaged kg 19 Gas Details Hourly Gas Consumption MJ Min Gas Pressure kPa Test Point Gas Pressure kPa Max Gas Pressure kPa minimum maximum Natural 188 1 13 0 20 0 83 3 50 LPG 188 2...

Page 55: ...INSTALLATION WATER HEATER 54 DIMENSIONS STANDARD CONTROLLERS Kitchen Controller Standard Bathroom Controller Standard...

Page 56: ...INSTALLATION WATER HEATER 55 DIMENSIONS DELUXE CONTROLLERS Deluxe Controller Cover Closed Deluxe Controller Cover Open...

Page 57: ...INSTALLATION WATER HEATER 56 TYPICAL INSTALLATION OUTDOOR LOCATION...

Page 58: ...ust not be installed An acceptable arrangement is shown in the diagram Refer also to Hot Water Delivery on page 48 and to Mains Water Supply on page 47 A disconnection union must always be provided at...

Page 59: ...to the connections on both the solar storage tank and the in series gas booster A full flow isolation valve must be installed on the water line to the in series gas booster GAS INLET The gas connecti...

Page 60: ...s been installed to an existing water heater installation then all controllers must be disconnected and removed The water heater is supplied with a 1 8 metre lead and plug and requires a weatherproof...

Page 61: ...K 2B or the Bathroom controller cable Paloma K 2C Notes Where more than one controller is installed the second or third controller must be of the same family A standard controller can only be install...

Page 62: ...he controllers are not weatherproof KITCHEN CONTROLLER The standard Kitchen controller Paloma MC 101 or Kitchen Deluxe controller Paloma MC 115 is to be installed in the kitchen or laundry only It has...

Page 63: ...ds 6 Connect the cable to the two terminals on the back of the controller connections are not polarity sensitive Ensure the connecting screws are seated tightly 7 Place the controller over the base pl...

Page 64: ...1 and 4 and make an opening in the thin section in the underside of the controller to accommodate the cable as shown in the diagram prior to Step 6 Kitchen Controller Standard and Deluxe Installation...

Page 65: ...setting of PH 246CWHA series 50 C The method of installation for the standard Bathroom1 and Bathroom2 controllers and the Bathroom1 Deluxe and Bathroom2 Deluxe controllers is identical Choose a suitab...

Page 66: ...the base plate 7 Fix the base plate to the wall using suitable screws and wall anchors Ensure the projections in the base plate are pointing upwards 8 Plug the controller wire into the Bathroom contr...

Page 67: ...It is important to seat the cables into the cable notches Failure to do this may cause an unstable contact or even disconnection of the cables from the terminals if the cables were to be pulled 6 Ref...

Page 68: ...rporated in the water heater is not adjustable To complete the installation it is necessary to check the gas supply pressure at the inlet to the water heater refer to Gas Inlet Pressure on page 67 the...

Page 69: ...switched on and turn on a controller if one is fitted by pressing the on off button 7 Open a hot tap fully and ensure the burners are fully ignited It may be necessary to open a second tap 8 Turn on a...

Page 70: ...e the burner pressure test point on the main burner manifold Remove the test point screw and washer from the test point orifice Connect the manometer 6 Switch on the electrical supply at the power out...

Page 71: ...e incoming cold water temperature Note In Step 9 4H will be shown on the LED display After setting the minimum and maximum test point gas pressures Close the hot tap Remove the manometer and refit and...

Page 72: ...the water heater Gas Booster for a Solar Water Heater Note Australian Standard AS 3498 requires that a water heater provides the means to inhibit the growth of Legionella bacteria in potable water Whe...

Page 73: ...ater 2 Remove the screws holding the front panel to the jacket 3 Gently disengage the front panel and pull forward to remove from the water heater 4 Switch on the electrical supply at the power outlet...

Page 74: ...tlet temperature compensation adjustment procedure Warnings The removal of the front panel will expose 240 volt wiring Take care not to touch wiring terminals The adjustment must be carried out by a q...

Page 75: ...ted the maximum outlet temperature of the water heater can be adjusted upwards 5 Turn off the hot tap 6 Switch off the electrical supply at the power outlet to the water heater 7 Remove the screws hol...

Page 76: ...ontroller s to the Water Heater on page 66 16 Refit the front panel and screws to the water heater 17 Switch on the electrical supply at the power outlet to the water heater TO TURN OFF THE WATER HEAT...

Page 77: ...y the shower outlet Unscrew the two drain plugs one each at the cold water inlet and hot water outlet on the underside of the water heater Water will drain from the water heater When water stops flowi...

Page 78: ...in information from your local water supply authority plumber or merchant This water heater is not suitable for connection to bore spring or rain water unless a water treatment device is fitted to buf...

Page 79: ...on in the waterways of a water heater with a frost protection system due to an ambient temperature below 20 C including wind chill factor ice formation in the water ways of a water heater where the wa...

Page 80: ...Revision Date 2013 January 31 76787 00 79...

Reviews: