35
Plumbing installations
1.
80kpa minimum to 1000kpa maximum water pressure to be supplied to unit
2.
Recommended 3/4'” (DN20) water piping. n.b. – ½” (DN15) is sufficient where necessary
3.
It is recommended that a Non-Return valve be installed on the hot water outlet of the unit
4.
A water shut-off valve must be installed on the cold water inlet
5.
It is recommended that conex type compression fittings are used for final connections on the unit
6.
For solar back-up installations, water of not more than 75 degrees centigrade can be fed through the unit
7.
All filters, including tap filters should be cleaned regularly for optimal performance
PLEASE NOTE: ALL PALOMA UNITS ARE CORRECTLY SET AND INDIVIDUALLY TESTED BY
THE MANUFACTURER. NO INTERNAL ADJUSTMENTS SHOULD BE MADE TO THE GAS
BURNER PRESSURES